Mechanical | Original | D | 12/14/2022 | JUSTINC | JUSTINC | Provide hood and KEF cutsheets with mechanical submittal Provide refrigeration calculations for each walk-in freezer or cooler on plan per 2015 IMC 1103.1 Verify on plan if within allowable limits. If over allowable limits indicate on plan how protecting Verify grease duct routing thru upper level.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Mechanical | 1782105 |
CO Springs Fire | Original | D | 12/7/2022 | CSFIRE | CSFIRE | WALK OK – See our “Virtual” Walk Through process here: https://coloradosprings.gov/sites/default/files/inline-images/walk-thru_memo.pdf
You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! | rpeterson | CO Springs Fire | 1779598 |
CO Springs Hazmat | Original | D | 12/7/2022 | CSFIRE | CSFIRE | | rpeterson | CO Springs Hazmat | 1779597 |
Plumbing | Original | D | 12/5/2022 | SHANEN | SHANEN | P3.1: Hand sinks shall be directly connected to the drainage system. P4.1: 3-comp sink detail does not comply with section 802.1.1 Food handling. See reviewer provided detail. Suspended water heater detail does not comply with section 607.3 Thermal expansion control. Thermal expansion control device shall be be connected to the water heater cold water supply pipe. P5.1: Provide required water pipe size analysis data, see 2018 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1778099 |
CO Springs DRE | Original | N | 12/1/2022 | ZNOYES | ZNOYES | Commercial Interior Remodel Only. No change of use or occupancy. Remodel of accessory kitchen space in movie theater (see full review) | | CO Springs DRE | 1777096 |
Electrical | Original | D | 12/1/2022 | SHELBY | SHELBY | 1. Use the 2015 IECC the 2018 has not been adopted. 2. Show feeder and MCB over current device ampacity on one line for new scope of work. 3. Include new refrigeration equipment SCA and SCCR on fault schedule. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Electrical | 1777077 |
Electronic Plan | Original | / | 11/30/2022 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1776741 |
Health Dept. | Original | D | 11/30/2022 | HEALTHDEPT | HEALTHDEPT | Retail food establishment minor remodel short form plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/service/retail-food-establishment-licensing-0. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. AF | Amanda Furno | Health Dept. | 1776633 |
Zoning/Planning | Original | / | 11/29/2022 | ZNOYES | ZNOYES | In Current Review by ZNOYES | | Zoning/Planning | 1776167 |
CSU Water | Original | D | 11/29/2022 | CSUREVIEW | CSUREVIEW | Provide a copy of the approved Utility Service Plan (USP) in the plan set. Call UDS at 719-668-8259 with questions. mjg | mgackle | CSU Water | 1776148 |
CSU Waste Water | Original | D | 11/29/2022 | CSUREVIEW | CSUREVIEW | Provide a copy of the approved Utility Service Plan (USP) in the plan set. Call UDS at 719-668-8259 with questions. mjg | mgackle | CSU Waste Water | 1776146 |
Construction | Original | D | 11/29/2022 | BPHILLIPS | BPHILLIPS | Scope of work shown on architectural sheets do not match that stated on the code study form. Please clarify. Unable to locate detail 4 A1.10 on plan Label new walls with wall type and provide legend. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1776105 |
Electronic Plan | Original | / | 11/29/2022 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 1775779 |
Enumeration | Original | N | 11/29/2022 | BECKYA | BECKYA | | | Enumeration | 1775718 |
Electronic Plan | Original | / | 11/28/2022 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1775635 |
Floodplain | Original | N | 11/23/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6432103019) | | Floodplain | 1775017 |