Energy | Original | A | 11/5/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2081866 |
Plumbing | Original | A | 11/5/2024 | SHANEN | SHANEN | | | Plumbing | 2081865 |
| Original | / | 11/5/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2081822 |
| Original | / | 11/5/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2081700 |
Submittal 6 | Original | / | 11/5/2024 | SIERRAC | SIERRAC | Submittal #6 | | Submittal 6 | 2081699 |
Energy | Original | D | 10/24/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2076699 |
Plumbing | Original | D | 10/24/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2076698 |
CSU Water | Original | A | 10/23/2024 | CSUREVIEW | CSUREVIEW | Comments addressed. CJS | cjsavage | CSU Water | 2076588 |
CSU Waste Water | Original | A | 10/23/2024 | CSUREVIEW | CSUREVIEW | Comments addressed. FOG variance letter provided. CJS | cjsavage | CSU Waste Water | 2076587 |
| Original | / | 10/23/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2076501 |
| Original | / | 10/23/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2076398 |
Submittal 5 | Original | / | 10/23/2024 | BRIANNAM | BRIANNAM | Submittal #5 | | Submittal 5 | 2076397 |
City Engr | Original | A | 10/22/2024 | JDAGNILLO | JDAGNILLO | | | City Engr | 2075565 |
CSU Contract Admin. | Original | A | 10/21/2024 | CSUAPPSPRM | CSUAPPSPRM | Commercial water meter sizing form approved and applicable development charges and fees paid. AMS | ASweet | CSU Contract Admin. | 2075411 |
CSU Water | Original | D | 10/18/2024 | CSUREVIEW | CSUREVIEW | Domestic and Fire service entries appear swapped between plumbing plans and approved Utility Plans. Revise plumbing and/or utility plans to ensure they are not swapped and/or ensure that the service lines do not cross each other. SSM | stefanm | CSU Water | 2074684 |
CSU Waste Water | Original | D | 10/18/2024 | CSUREVIEW | CSUREVIEW | Contact fog@csu.org to have grease trap variance letter updated with correct address.
See PPRBD Plumbing's comments regarding incorrect fixture drainage into grease trap. Dishwasher shall not drain to GT, hand sink shall drain to GT. SSM
SSM | stefanm | CSU Waste Water | 2074678 |
CO Springs DRE | Original | A | 10/18/2024 | SSADLER | SSADLER | Site dimensional standards met. FA's are on file and all fees have been paid. (see full review) | | CO Springs DRE | 2074516 |
Zoning/Planning | Original | / | 10/17/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2074279 |
CSU Waste Water | Original | A | 10/17/2024 | CSUREVIEW | CSUREVIEW | Comments addressed. mjg | mgackle | CSU Waste Water | 2074192 |
Energy | Original | D | 10/17/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2074172 |
Plumbing | Original | D | 10/17/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2074171 |
| Original | / | 10/17/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2074132 |
| Original | / | 10/17/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2074113 |
Submittal 4 | Original | / | 10/17/2024 | BRIANNAM | BRIANNAM | Submittal #4 | | Submittal 4 | 2074112 |
CO Springs DRE | Original | D | 10/16/2024 | CHUDSPETH | CHUDSPETH | Plans have been denied until planner review is complete. All CDI fees were paid on 10/16/2024 (see full review) | | CO Springs DRE | 2073329 |
Health Dept. | Original | A | 10/1/2024 | HEALTHDEPT | HEALTHDEPT | Childcare facility approved in plan review. A pre-operational inspection will be required before final approval for opening is granted.
Construction Activity Permit (PT1535) is approved from 10/10/2024 - 4/10/2024. After 4/10/2024, applicant must renew permit. | ddominguez | Health Dept. | 2066820 |
City Engr | Original | D | 9/27/2024 | JDAGNILLO | JDAGNILLO | Please upload a receipt for proof of payment of the $30,749.47 for the cost recovery against this lot. Thank you. | | City Engr | 2065681 |
Energy | Original | D | 9/27/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2065488 |
Plumbing | Original | D | 9/27/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2065487 |
CO Springs DRE | Original | D | 9/24/2024 | SSADLER | SSADLER | Site dimensional standards met. However, the only remaining comment is to collect police and fire fees. Financial assurances must be posted prior to building permit release. Contact DREPlanning@coloradosprings.gov to discuss (see full review) | | CO Springs DRE | 2064054 |
Health Dept. | Original | D | 9/24/2024 | HEALTHDEPT | HEALTHDEPT | Construction activity permit application is under review and not yet approved. For questions, contact Environmental Health at 719-578-3199 option 3.
Childcare facility plan review is in process and not yet approved. If your assigned plan reviewer has questions, they will contact you directly. For questions, contact Environmental Health at 719-578-3199 option 3. KB | KBauer | Health Dept. | 2063763 |
Electrical | Original | A | 9/23/2024 | BERTHA | BERTHA | | | Electrical | 2063572 |
Electronic Plan | Original | / | 9/23/2024 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2063540 |
Zoning/Planning | Original | / | 9/23/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2063460 |
CSU Water | Original | D | 9/23/2024 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. MLW | mlwilliams | CSU Water | 2063388 |
CSU Waste Water | Original | D | 9/23/2024 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. MLW | mlwilliams | CSU Waste Water | 2063387 |
Gas/Elec. Utils | Original | A | 9/23/2024 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. MLW | mlwilliams | Gas/Elec. Utils | 2063386 |
CSU Contract Admin. | Original | D | 9/23/2024 | CSUAPPSPRM | CSUAPPSPRM | Commercial Water Meter sizing form approved - Requires payment of applicable development fees/charges. Please contact our office at 719-668-8111 / cca@csu.org for additional information. JD | jdemello | CSU Contract Admin. | 2063337 |
Construction | Original | A | 9/23/2024 | BPHILLIPS | BPHILLIPS | | | Construction | 2063334 |
Electronic Plan | Original | / | 9/19/2024 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2062574 |
Enumeration | Original | A | 9/19/2024 | BRENT | BRENT | | | Enumeration | 2062494 |
Electronic Plan | Original | / | 9/19/2024 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2062472 |
| Original | / | 9/19/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2062460 |
| Original | / | 9/19/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2062435 |
Submittal 3 | Original | / | 9/19/2024 | BRIANNAM | BRIANNAM | Submittal #3 | | Submittal 3 | 2062434 |
City Engr | Original | D | 9/11/2024 | JDAGNILLO | JDAGNILLO | See previous comment - Include a copy of the approved Development Plan and a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set.
In addition, 8040 Grandiose Hts. has a cost recovery agreement recorded against it in the amount of $30,749.47 (if paid prior to the end of 2024). Please contact Jeff Bailey (Jeff.Bailey@coloradosprings.gov) to pay this amount. It must be received prior to issuance of building permit. Thank you. | | City Engr | 2058729 |
Energy | Original | D | 9/10/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2058239 |
Electrical | Original | A | 9/10/2024 | BERTHA | BERTHA | | | Electrical | 2058238 |
Electronic Plan | Original | / | 9/10/2024 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2058087 |
Health Dept. | Original | D | 9/10/2024 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/.
Childcare facility plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/child-care/. Please email application and all required documents to healthinfo@elpasoco.com.
For questions, contact Environmental Health at 719-578-3199 option 3. AB | abrannon | Health Dept. | 2058008 |
CO Springs DRE | Original | D | 9/10/2024 | SSADLER | SSADLER | Previous comment not addressed. The approved development plan will have the Land Use Review stamp on it. Please upload the approved stamped development plan (see full review) | | CO Springs DRE | 2057919 |
Mechanical | Original | A | 9/9/2024 | DALEH | DALEH | | | Mechanical | 2057325 |
CO Springs Hazmat | Original | N | 9/9/2024 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2057203 |
CSU Contract Admin. | Original | D | 9/9/2024 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate.
CWMSF received, however requires corrections.
AMS | ASweet | CSU Contract Admin. | 2057190 |
CSU Water | Original | D | 9/6/2024 | CSUREVIEW | CSUREVIEW | Contact CSU Industrial Pretreatment representative Bob Bowren via email at fog@csu.org to determine if a variance for an interior grease trap is applicable. If applicable, provide a copy of the Variance letter in the building plan set.
Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. SSM | stefanm | CSU Water | 2056451 |
CSU Waste Water | Original | D | 9/6/2024 | CSUREVIEW | CSUREVIEW | Contact CSU Industrial Pretreatment representative Bob Bowren via email at fog@csu.org to determine if a variance for an interior grease trap is applicable. If applicable, provide a copy of the Variance letter in the building plan set.
Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSM | stefanm | CSU Waste Water | 2056448 |
Gas/Elec. Utils | Original | D | 9/6/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSM | stefanm | Gas/Elec. Utils | 2056447 |
Zoning/Planning | Original | / | 9/6/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2056442 |
Plumbing | Original | D | 9/6/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2056414 |
Construction | Original | D | 9/6/2024 | BPHILLIPS | BPHILLIPS | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 2056384 |
Electronic Plan | Original | / | 9/6/2024 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2056375 |
Enumeration | Original | D | 9/5/2024 | BRENT | BRENT | See comments 7/26/24 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Enumeration | 2056354 |
Electronic Plan | Original | / | 9/5/2024 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2056341 |
Submittal 2 | Original | / | 9/5/2024 | BRIANNAM | BRIANNAM | Submittal #2 | | Submittal 2 | 2056317 |
Electrical | Original | D | 8/20/2024 | BERTHA | BERTHA | Comply with 250.122 NEC
Provide fault current information (SCCR, AIC, SCA) in tabular format at all of the following locations. 1. All new panelboards and switchboards 2. All new transfer equipment 3. All new industrial control panels 4. All new air conditioning and refrigeration equipment 5. At any of the above locations when refed
Provide compliance with 422.5 NEC
Vestibules must be identified on plans as conditioned or unconditioned. If the vestibule is conditioned or an air curtain is specified, show compliance with C403.4.1.4.
Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10.
Controlled receptacles must be shown on the plan per C405.11 and the symbol used to mark these receptacles must be as shown in article 406.3(E) of the adopted National Electrical Code (NEC).
The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.” 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 2048964 |
Energy | Original | D | 8/20/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2048965 |
Electronic Plan | Original | / | 8/20/2024 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2048876 |
CO Springs Fire | Original | A | 8/16/2024 | CSFIRE | CSFIRE | You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! (see full review) | phil.valdez | CO Springs Fire | 2048081 |
CO Springs Hazmat | Original | D | 8/16/2024 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2048080 |
Mechanical | Original | D | 8/14/2024 | DALEH | DALEH | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 2046774 |
Electronic Plan | Original | / | 8/14/2024 | TREVORH | TREVORH | In Current Review by TREVORH | | Electronic Plan | 2046483 |
Electronic Plan | Original | / | 8/12/2024 | TREVORH | TREVORH | In Current Review by TREVORH | | Electronic Plan | 2045199 |
Health Dept. | Original | D | 8/9/2024 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/.
Childcare facility plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/child-care/. Please email application and all required documents to healthinfo@elpasoco.com.
For questions, contact Environmental Health at 719-578-3199 option 3. AM | Amanda Furno | Health Dept. | 2044836 |
City Engr | Original | D | 8/8/2024 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan and a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set.
In addition, 8040 Grandiose Hts. has a cost recovery agreement recorded against it in the amount of $30,749.47 (if paid prior to the end of 2024). Please contact Jeff Bailey (Jeff.Bailey@coloradosprings.gov) to pay this amount. It must be received prior to issuance of building permit. Thank you. | | City Engr | 2044182 |
CO Springs DRE | Original | D | 8/7/2024 | SSADLER | SSADLER | Upload the approved stamped development plan (see full review) | | CO Springs DRE | 2043134 |
Plumbing | Original | D | 8/7/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2042987 |
Elevators | Original | N | 8/6/2024 | ERIC | ERIC | No conveyance | | Elevators | 2042926 |
CSU Contract Admin. | Original | D | 8/6/2024 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 to discuss charges/fees and request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
BS | bschifferstein | CSU Contract Admin. | 2042329 |
CSU Water | Original | D | 8/6/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. -------------------------------------------------------------------------------------------------------------------------------------------------------------- Service entry locations between the plumbing plans and civil construction drawings must match. ------------------------------------------------------------------------------------------------------------------------------------------------------------ Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. MLW | mlwilliams | CSU Water | 2042278 |
CSU Waste Water | Original | D | 8/6/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. MLW | mlwilliams | CSU Waste Water | 2042277 |
Gas/Elec. Utils | Original | D | 8/6/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. MLW | mlwilliams | Gas/Elec. Utils | 2042276 |
Zoning/Planning | Original | / | 8/5/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2041940 |
Construction | Original | D | 8/5/2024 | BPHILLIPS | BPHILLIPS | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 2041923 |
Electronic Plan | Original | / | 8/2/2024 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2041412 |
Enumeration | Original | D | 7/26/2024 | BRENT | BRENT | Include a copy of whatever RECORDED document will remove the lot lines between lots 1 and 2. Enumerations will not approve without a copy of this recorded document in our records. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Enumeration | 2037920 |
Electronic Plan | Original | / | 7/26/2024 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2037909 |
Energy | Original | / | 7/25/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2037488 |
Floodplain | Original | N | 7/25/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5309201044) | | Floodplain | 2037487 |