Electronic Plan | Original | / | 6/23/2025 | BRIANB | BRIANB | In Current Review by BRIANB | | Electronic Plan | 2175481 |
| Original | / | 6/19/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2174214 |
| Original | / | 6/19/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2174212 |
Submittal 3 | Original | / | 6/19/2025 | QUINTONW | QUINTONW | Submittal #3 | | Submittal 3 | 2174211 |
CO Springs Hazmat | Original | D | 5/22/2025 | CSFIRE | CSFIRE | See Fire Comments | michael.davis1@color | CO Springs Hazmat | 2162055 |
CO Springs Fire | Original | D | 5/22/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | michael.davis1@color | CO Springs Fire | 2162054 |
Energy | Original | D | 5/19/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2160038 |
Mechanical | Original | D | 5/19/2025 | TCRIPPEN | TCRIPPEN | Disapproved: Furnace is in a small tight area boxed in . We have concerns. and we have concerns about grease duct as well Grease duct would need to be in a fire rated room * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2160037 |
CO Springs DRE | Original | A | 5/15/2025 | MAMBUUL | MAMBUUL | Approved for commercial change of occupancy. Plans are consistent with approved plan set stamped by land use review. | | CO Springs DRE | 2159527 |
EPC Health Dept | Original | D | 5/14/2025 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/retail-food/retail-food-establishments/. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. BR | brothrock | EPC Health Dept | 2158652 |
Electronic Plan | Original | / | 5/14/2025 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 2158527 |
Zoning/Planning | Original | / | 5/14/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2158405 |
Plumbing | Original | D | 5/14/2025 | SHANEN | SHANEN | Construction review comments regarding occupant load must be addressed to verify compliance with section 403.1. Piping insulation material schedule must include thickness, material (fiberglass, elastomeric foam, etc.) and manufacturer. Reference 2021 IPC tables. Provide required CSU variance letter for the indoor grease interceptor. Contact Robert Bowren at 719-668-1735 or fog@csu.org.CSU indoor grease interceptor variance letter will regulate which fixtures are required to discharge through the grease interceptor. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2158400 |
CSU Water | Original | D | 5/13/2025 | CSUREVIEW | CSUREVIEW | On the plumbing sheet indicate if the water service entry is existing or NEW. If new, requires a Utility Service Plan.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. Place both meter details andmeter clearance details. mjg | mgackle | CSU Water | 2158364 |
CSU Waste Water | Original | D | 5/13/2025 | CSUREVIEW | CSUREVIEW | A variance is required for this unit as it is located too far from the existing grease interceptor. Contact CSU Industrial Pretreatment representative Bob Bowren via email at fog@csu.org to request a variance for this condition. Provide a copy of the Variance Letter in the building plan set. mjg | mgackle | CSU Waste Water | 2158360 |
Construction | Original | D | 5/13/2025 | BRIANB | BRIANB | Preliminary review only (no walk) * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2158320 |
Electrical | Original | D | 5/12/2025 | RICHG | RICHG | Show compliance with 240.24 NEC 2023.
Pending constructions review. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2157729 |
Electronic Plan | Original | / | 5/8/2025 | BRIANB | BRIANB | In Current Review by BRIANB | | Electronic Plan | 2156114 |
Submittal 2 | Original | / | 5/8/2025 | SIERRAC | SIERRAC | Submittal #2 | | Submittal 2 | 2156063 |
Energy | Original | D | 12/30/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2103537 |
Mechanical | Original | D | 12/30/2024 | TCRIPPEN | TCRIPPEN | Disapproved Com check required for MUA unit and new furnace, * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2103536 |
CO Springs Fire | Original | D | 12/23/2024 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | chiptaylor | CO Springs Fire | 2102324 |
CO Springs Hazmat | Original | D | 12/23/2024 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2102323 |
EPC Health Dept | Original | D | 12/17/2024 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/retail-food/retail-food-establishments/. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. KB | KBauer | EPC Health Dept | 2099768 |
CO Springs DRE | Original | D | 12/17/2024 | SSADLER | SSADLER | I appears that the entitlement for a minor improvement is still in review. Once FBZN-23-0012 is approved, upload the approved stamped plans and the approval letter. | | CO Springs DRE | 2099699 |
Plumbing | Original | D | 12/16/2024 | SHANEN | SHANEN | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2099437 |
CSU Waste Water | Original | D | 12/16/2024 | CSUREVIEW | CSUREVIEW | GI-1 cannot be located under the patio. It must be accessible for maintenance every 30 to 60 days.
New exterior sanitary service lines require an approved Utility Service Plan to be attached to the permit set. CJS | cjsavage | CSU Waste Water | 2099419 |
Zoning/Planning | Original | / | 12/16/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2099413 |
CSU Water | Original | D | 12/16/2024 | CSUREVIEW | CSUREVIEW | Re: C173649, existing water entry is shown on the west side of building. C196885 shows existing water entry on north side of building. New water service lines require an approved Utility Service Plan.
Meter cannot be located interior to the building after the restrooms. Meter riser must be near the exterior wall. CJS | cjsavage | CSU Water | 2099402 |
Electrical | Original | D | 12/16/2024 | BERTHA | BERTHA | Clarify whether Panel C is new or existing.
Verify compliance with 240.24
Pending Construction review - see construction review comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2099397 |
Electronic Plan | Original | / | 12/16/2024 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2099385 |
Construction | Original | D | 12/16/2024 | BRIANB | BRIANB | Preliminary review only * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2099365 |
Enumeration | Original | N | 12/11/2024 | BRENT | BRENT | | | Enumeration | 2097754 |
Electronic Plan | Original | / | 12/11/2024 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2097744 |
Energy | Original | / | 12/11/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2097368 |
Floodplain | Original | N | 12/11/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6418404001) | | Floodplain | 2097367 |