CO Springs DRE | Original | A | 3/7/2025 | MAMBUUL | MAMBUUL | Approved for new level 1 EV chargers. No change to setbacks, use or parking. Note: EV chargers may not impede/encroach into any ADA parking space or ADA loading zone within stalls or loading zones. | | CO Springs DRE | 2128463 |
Zoning/Planning | Original | / | 3/7/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2128433 |
Enumeration | Original | N | 3/6/2025 | BRENT | BRENT | | | Enumeration | 2128213 |
Electronic Plan | Original | / | 3/6/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2128195 |
| Original | / | 3/6/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2127990 |
| Original | / | 3/6/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2127755 |
Submittal 3 | Original | / | 3/6/2025 | BRIANNAM | BRIANNAM | Submittal #3 | | Submittal 3 | 2127754 |
CO Springs Fire | Original | N | 2/28/2025 | CSFIRE | CSFIRE | level 1 EV chargers. No Fire Final Required | chiptaylor | CO Springs Fire | 2126091 |
CO Springs Hazmat | Original | N | 2/28/2025 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2126089 |
Energy | Original | D | 2/27/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2125521 |
Mechanical | Original | N | 2/27/2025 | TCRIPPEN | TCRIPPEN | no mechanical per posed | | Mechanical | 2125520 |
Electrical | Original | D | 2/27/2025 | DANIELG | DANIELG | Provide panel schedules with load summaries.
Provide an electrical site plan.
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2125465 |
Elevators | Original | D | 2/27/2025 | ANDREAL | ANDREAL | The previous comment was not addressed. The Code Study Form is checked 'Yes' for 'Project includes a Conveyance'. There are no sheets indicating alterations or additions related to conveyances. Please correct Code Study form to reflect 'No' or provide sheets related to conveyances. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2125440 |
CO Springs DRE | Original | D | 2/21/2025 | MAMBUUL | MAMBUUL | Previous comments not addressed. 1. Need to upload a scaled site plan with locations of proposed EV chargers to permit. 2. Need to provide what level of EV charger they are on the code study form. | | CO Springs DRE | 2123547 |
Zoning/Planning | Original | / | 2/21/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2123479 |
CSU Water | Original | N | 2/20/2025 | CSUREVIEW | CSUREVIEW | No plumbing scope of work. MLW | mlwilliams | CSU Water | 2123202 |
CSU Waste Water | Original | N | 2/20/2025 | CSUREVIEW | CSUREVIEW | No plumbing scope of work. MLW | mlwilliams | CSU Waste Water | 2123195 |
Enumeration | Original | D | 2/20/2025 | BRENT | BRENT | see comment 01/06/25 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2122997 |
Electronic Plan | Original | / | 2/20/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2122987 |
Submittal 2 | Original | / | 2/19/2025 | QUINTONW | QUINTONW | Submittal #2 | | Submittal 2 | 2122282 |
EPC Health Dept | Original | N | 1/13/2025 | HEALTHDEPT | HEALTHDEPT | Not applicable. Per Ryan Trullinger, "There will be no earth moving. This plan is for adding to EV chargers to the already complete building." AB | abrannon | EPC Health Dept | 2107795 |
Energy | Original | D | 1/8/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2106087 |
Mechanical | Original | D | 1/8/2025 | TCRIPPEN | TCRIPPEN | Disapproved show location of chargers on plan ? * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2106086 |
Electrical | Original | D | 1/8/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2105954 |
Electronic Plan | Original | / | 1/8/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2105953 |
Plumbing | Original | N | 1/8/2025 | SHANEN | SHANEN | | | Plumbing | 2105896 |
Elevators | Original | D | 1/7/2025 | ROBERTV | ROBERTV | The Code Study Form is checked 'Yes' for 'Project includes a Conveyance'. There are no sheets indicating alterations or additions related to conveyances. Please correct Code Study form to reflect 'No' or provide sheets related to conveyances. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2105874 |
CO Springs Fire | Original | D | 1/7/2025 | CSFIRE | CSFIRE | DISAPPROVED COMMENTS The following information and/or corrections are needed prior to completing a full plan review. Please respond, in writing on letterhead, to each of the following comments:
1. Provide what level EV chargers will be
2. revise code study form to match scope, current form is for new building | Jacob.Watson | CO Springs Fire | 2105565 |
CO Springs Hazmat | Original | D | 1/7/2025 | CSFIRE | CSFIRE | See Fire Comments | Jacob.Watson | CO Springs Hazmat | 2105564 |
CO Springs DRE | Original | D | 1/7/2025 | MAMBUUL | MAMBUUL | 1. Need to provide site plan with locations of proposed EV chargers. 2. Need to provide what level EV chargers are on the code study form. | | CO Springs DRE | 2105409 |
Zoning/Planning | Original | / | 1/6/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2104908 |
CSU Water | Original | D | 1/6/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan OR CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Need to ensure conduit is not crossing any utility service lines.MDA | malcuran | CSU Water | 2104905 |
CSU Waste Water | Original | D | 1/6/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan OR CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Need to ensure conduit is not crossing any utility service lines.MDA | malcuran | CSU Waste Water | 2104904 |
Enumeration | Original | D | 1/6/2025 | BRENT | BRENT | A site plan is required for all commercial projects. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2104830 |
Electronic Plan | Original | / | 1/6/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2104828 |
Energy | Original | / | 12/27/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2102782 |
Floodplain | Original | N | 12/27/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6418324045) | | Floodplain | 2102781 |