PROCESSING....
Skip to main content
Pikes Peak Regional Building Department
Ensuring life safety and welfare of our community through efficient and consistent application of adopted codes and standards.
Home
Contact
Search
Accessibility
Cart
Sign In
Home
Contact
Search
Accessibility
Cart
Sign In
Plan Details
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Plan #
  
Type
 
Plan
Owner
Address
6755 PANAMINT CT, COLORADO SPRINGS, CO 80915
Parcel Info
5407400111
Truss P/SF
30 (Elevation: 6,276 Feet)
Project
NEW SERVICE/SERVICE UPGRADE (
437
)
Type Of Plan
Normal
Review Type
Electronic
Fire District
CIMARRON HILLS FIRE PROTECTION DISTRICT
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 4
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Electrical
A
0
E
Electrical
Energy
N
G
Energy
Enumeration
D
0
N
Enumeration
Floodplain
N
W
Floodplain
Log Entries: 6
Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
Electrical
Original
A
1/23/2025
DANIELG
DANIELG
Electrical
2112002
Electronic Plan
Original
/
1/23/2025
DANIELG
DANIELG
In Current Review by DANIELG
Electronic Plan
2112000
Enumeration
Original
D
1/21/2025
AMY
AMY
What is the modular building be used for? Where is the main door to the modular?
A separate address needs to be assigned.
When is the modular building going to be permitted?
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Enumeration
2110516
Electronic Plan
Original
/
1/21/2025
AMY
AMY
In Current Review by AMY
Electronic Plan
2110513
Energy
Original
N
1/16/2025
SYSTEM
SYSTEM
Energy Department review not required under 2023 PPRBC when IECC is N/A
Energy
2109179
Floodplain
Original
N
1/16/2025
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5407400111)
Floodplain
2109178