CO Springs Fire | Original | D | 2/25/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | Jacob.Watson | CO Springs Fire | 2124757 |
CO Springs Hazmat | Original | N | 2/25/2025 | CSFIRE | CSFIRE | NA | Jacob.Watson | CO Springs Hazmat | 2124756 |
Energy | Original | D | 2/21/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2123573 |
Electrical | Original | A | 2/21/2025 | DANIELG | DANIELG | | | Electrical | 2123572 |
Electronic Plan | Original | / | 2/21/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2123565 |
Mechanical | Original | D | 2/19/2025 | TREVORH | TREVORH | Disapproved;signature Needs to match stamp * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2122542 |
County Zoning | Original | D | 2/19/2025 | DSDHOWSER | DSDHOWSER | Site development plan package was not submitted to El Paso County PCD. Site development plan submittal is required to initiate variance of use. The plan provided in BDA is of the variance of use site plan and is not an approved site development plan. | | County Zoning | 2122007 |
EPC Health Dept | Original | N | 2/14/2025 | HEALTHDEPT | HEALTHDEPT | Not applicable. BR | brothrock | EPC Health Dept | 2121185 |
Construction | Original | D | 2/14/2025 | BPHILLIPS | BPHILLIPS | Foundation letter, Comcheck. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2121064 |
Plumbing | Original | D | 2/14/2025 | SHANEN | SHANEN | See highlighted sections on clouded additional requirements for 2021 IECC block. Provided water pipe size analysis data is incomplete. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Reference 2021 IPC code sections. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Enumeration comments must be addressed. Expansion tank model is for residential use only per manufacturer website. Building drain location does not match the provided site plan. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. Water service is not shown on referenced civil (site) plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2121048 |
Electronic Plan | Original | / | 2/12/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2120367 |
Enumeration | Original | D | 2/10/2025 | AMY | AMY | Commercial structure require a separate address. New address for the office building will be 5941 Templeton Gap Road. Change the address on all pages to this address. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2119079 |
Electronic Plan | Original | / | 2/10/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2119049 |
Waste Water Div | Original | / | 2/7/2025 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2118775 |
Water Division | Original | / | 2/7/2025 | SYSTEM | SYSTEM | You will need to contact Water Division department for approval prior to permit. This department will not review the plan electronically. | | Water Division | 2118774 |
Energy | Original | / | 2/7/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2118773 |
Floodplain | Original | N | 2/7/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6313000009) | | Floodplain | 2118772 |