CO Springs Fire | Original | N | 2/28/2025 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Fire | 2126098 |
CO Springs Hazmat | Original | N | 2/28/2025 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2126097 |
Energy | Original | D | 2/25/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2124563 |
Electrical | Original | A | 2/25/2025 | DANIELG | DANIELG | | | Electrical | 2124562 |
Electronic Plan | Original | / | 2/25/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2124560 |
Mechanical | Original | N | 2/24/2025 | TCRIPPEN | TCRIPPEN | No mechanical | | Mechanical | 2124087 |
CO Springs DRE | Original | A | 2/21/2025 | MAMBUUL | MAMBUUL | Approved for commercial interior remodel of existing bathrooms. No change is use, exterior, or parking. | | CO Springs DRE | 2123452 |
CSU Water | Original | N | 2/20/2025 | CSUREVIEW | CSUREVIEW | No new water service outside of building. MLW | mlwilliams | CSU Water | 2122986 |
CSU Waste Water | Original | N | 2/20/2025 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. MLW | mlwilliams | CSU Waste Water | 2122985 |
Zoning/Planning | Original | / | 2/20/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2122774 |
Construction | Original | D | 2/20/2025 | BPHILLIPS | BPHILLIPS | Ambulatory stall, room usage. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2122749 |
Plumbing | Original | D | 2/19/2025 | SHANEN | SHANEN | See highlighted section on clouded additional requirements for 2021 IECC block. EWC-1 does not comply with section 410.3. All plumbing fixtures must be scheduled with manufacturer model number per PPRBD plumbing plan review requirements provide model number for LV1 and LV2. Noted section C405 does not reference hot water systems. Heated water supply piping shall comply with 2021 IECC section C404.5.1. Lavatories must show compliance with 2021 IECC section C404.5.1. All backgrounds must match per PPRBD plan review requirements show location of and piping for the drinking fountains shown on the architectural plans. Drinking fountain locations as shown on the architectural plans do not comply with section 410.5. UR1 must show compliance with section 405.3.5. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2121997 |
Electronic Plan | Original | / | 2/18/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2121635 |
Enumeration | Original | N | 2/14/2025 | BRENT | BRENT | | | Enumeration | 2121042 |
Electronic Plan | Original | / | 2/14/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2121023 |
Energy | Original | / | 2/13/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2120459 |
Floodplain | Original | N | 2/13/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6406202002) | | Floodplain | 2120458 |