Energy | Original | D | 3/6/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2128084 |
Electrical | Original | D | 3/6/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2128083 |
Electronic Plan | Original | / | 3/6/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2128070 |
Mechanical | Original | D | 3/5/2025 | TREVORH | TREVORH | Disapproved;Code Study Form // Accessibility // Egress // Occupancy need to see construction review comments addressed * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2127330 |
EPC Health Dept | Original | N | 3/5/2025 | HEALTHDEPT | HEALTHDEPT | Not applicable. Per Mason Nguyen no retail food establishment will be on premise. TG | tguerrero | EPC Health Dept | 2127263 |
Plumbing | Original | D | 3/4/2025 | SHANEN | SHANEN | Construction review comments regarding occupant load must be addressed to verify compliance with section 403.1. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. P001: Fixture schedule does not match fixture tags provided on the plumbing floor plans. Schedule DF. Mop sink requires a minimum 2" trap and drain per manufacturer specs. 1-1/2" clothes washer trap/drain does not comply with section 406.2. P002: Provided water pipe size analysis data is incomplete. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. P004: Water piping diagram sizing does not match sheet P002. Dual check valve type backflow preventer is not approved for high hazard applications. Provide a device approved for a high degree of hazard. 1-1/2" clothes washer trap/drain does not comply with section 406.2. Waste piping for MS and WM is 2" connecting to 3" per plumbing sanitary plan * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2126901 |
Elevators | Original | N | 3/3/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2126691 |
CO Springs DRE | Original | D | 2/28/2025 | MAMBUUL | MAMBUUL | Please upload approved development plans approved by land use review to permit for commercial interior finish. | | CO Springs DRE | 2126140 |
CSU Water | Original | A | 2/28/2025 | CSUREVIEW | CSUREVIEW | Refer to core and shell permit for approved development plan and approved utility construction drawings. MLW | mlwilliams | CSU Water | 2126080 |
CSU Waste Water | Original | A | 2/28/2025 | CSUREVIEW | CSUREVIEW | Refer to core and shell permit for approved development plan and approved utility construction drawings. MLW | mlwilliams | CSU Waste Water | 2126077 |
Gas/Elec. Utils | Original | A | 2/28/2025 | CSUREVIEW | CSUREVIEW | Refer to core and shell permit for approved development plan and approved utility construction drawings. MLW | mlwilliams | Gas/Elec. Utils | 2126076 |
Zoning/Planning | Original | / | 2/28/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2126063 |
City Engr | Original | N | 2/28/2025 | HVO | HVO | | | City Engr | 2125961 |
CSU Contract Admin. | Original | A | 2/28/2025 | CSUAPPSPRM | CSUAPPSPRM | Utility Charges and Fees paid 2/28/25. JMD | jdemello | CSU Contract Admin. | 2125927 |
Construction | Original | D | 2/28/2025 | DOUGC | DOUGC | Code Study Form // Accessibility // Egress // Occupancy * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2125909 |
Electronic Plan | Original | / | 2/21/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2123874 |
Enumeration | Original | A | 2/20/2025 | BRENT | BRENT | | | Enumeration | 2123078 |
Electronic Plan | Original | / | 2/20/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2123064 |
Energy | Original | / | 2/19/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2122440 |
Floodplain | Original | N | 2/19/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6204409019) | | Floodplain | 2122439 |