CO Springs DRE | Original | D | 5/6/2025 | SSADLER | SSADLER | Upload the pre application summary. Financial assurances may need to be posted. | | CO Springs DRE | 2155266 |
EPC Health Dept | Original | D | 5/2/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. MT | mtemple | EPC Health Dept | 2153778 |
City Engr | Original | D | 5/1/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set. | | City Engr | 2153102 |
CSU Contract Admin. | Original | D | 5/1/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
AMS | ASweet | CSU Contract Admin. | 2153099 |
CSU Water | Original | D | 5/1/2025 | CSUREVIEW | CSUREVIEW | Will re-review after comments on Plumbing sheets are revised. mjg | mgackle | CSU Water | 2152845 |
CSU Waste Water | Original | D | 5/1/2025 | CSUREVIEW | CSUREVIEW | Will re-review after comments on Plumbing sheets are revised. mjg | mgackle | CSU Waste Water | 2152844 |
Gas/Elec. Utils | Original | A | 5/1/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. mjg | mgackle | Gas/Elec. Utils | 2152842 |
Energy | Original | D | 4/30/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2152600 |
Electrical | Original | D | 4/30/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2152599 |
Electronic Plan | Original | / | 4/30/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2152571 |
Plumbing | Original | D | 4/30/2025 | SHANEN | SHANEN | Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Provided water pipe size analysis data is incomplete. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Provide a piping materials schedule. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2152496 |
Zoning/Planning | Original | / | 4/30/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2152487 |
Mechanical | Original | D | 4/30/2025 | TCRIPPEN | TCRIPPEN | Disapproved: FIRE DAMPERS are required in rated walls. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2152476 |
Elevators | Original | N | 4/30/2025 | ANDREAL | ANDREAL | No Conveyance in this scope of work. | | Elevators | 2152444 |
Energy | Original | / | 4/30/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2152438 |
Construction | Original | D | 4/30/2025 | DOUGC | DOUGC | Life Safety Plan // Restrooms // IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2152436 |
Enumeration | Original | D | 4/28/2025 | BECKYA | BECKYA | New buildings receive separate addresses. The address for the new structure is 785 Aviation Way. Please update all plan pages to show the new address. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2151211 |
Electronic Plan | Original | / | 4/28/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2151209 |
Electronic Plan | Original | / | 4/25/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2150868 |
Enumeration | Original | A | 4/24/2025 | BECKYA | BECKYA | | | Enumeration | 2150038 |
Electronic Plan | Original | / | 4/24/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2150031 |
Floodplain | Original | N | 4/23/2025 | KEITH | KEITH | | | Floodplain | 2149778 |
Energy | Original | / | 4/23/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2149387 |
Floodplain | Original | / | 4/23/2025 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 5400000309) | | Floodplain | 2149386 |