| Forest Lakes Waste Water | Original | D | 11/17/2026 | FORESTLAKES | FORESTLAKES | 1. Per the Town of Monument Sanitary Sewer Standards, Chapter 5-9, Subsection C.3.b, the minimum size of the sand/oil separator for a repair garage with a floor area of 3,001-6,000 sq. feet is 1000 gallons. Please include Detail 21 (Sand/Oil Interceptor) from the Sanitary Sewer Standards.
2. Please clarify the location of the proposed sanitary service on Sheet 5 of the Civil Plans. The plumbing plans show the sanitary service exiting the southwest side of the building, while the civil plans show the sanitary service exiting the northeast side of the building.
3. Civil Plans Sheet 5: per the Town of Monument Sanitary Sewer Standards, Chapter 4-2, Subsection E.4.a, sewer service lines are not allowed to connect to manholes. No sewer service line shall connect to the main closer than 5 feet to the upstream manhole.
4. Use the following link to view the sanitary sewer standards: https://www.townofmonument.org/DocumentCenter/View/238/Sanitary-Sewer-Collection-System-Specifications-PDF | rnortonFLMD | Forest Lakes Waste Water | 2383397 |
| Monument Hazmat | Original | A | 11/10/2026 | MONUMENTFIRE | MONUMENTFIRE | | SBenson9 | Monument Hazmat | 2380793 |
| Monument Fire | Original | A | 11/10/2026 | MONUMENTFIRE | MONUMENTFIRE | New construction is subject to impact fees. An invoice has been sent to the applicant for this permit.
A New Construction permit is required for this project
WRC permits are required for this permit. Please apply at www.monumentfire.org/permits
This review is based on the 2021 International Fire Code (IFC), as adopted and amended by Monument Fire District, including all applicable policies and standards. This review is limited to fire and life safety considerations and does not constitute approval of structural, electrical, plumbing, or other disciplines. | SBenson9 | Monument Fire | 2380792 |
| Energy | Original | D | 11/9/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2379994 |
| Mechanical | Original | D | 11/9/2026 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2379993 |
| Construction | Original | A | 11/6/2026 | DOUGC | DOUGC | Approved per new mechanical sheets | | Construction | 2379795 |
| EPC Health Dept | Original | N | 11/4/2026 | HEALTHDEPT | HEALTHDEPT | Construction activity permit PT1800 is valid from 11/2/2026 - 5/2/2027. To continue any earthmoving operations after 5/2/2027, please reapply for a new permit online through https://myhealthdepartment.com/EPCPH. For questions, contact Environmental Health at 719-578-3199 option 3. MT | mtemple | EPC Health Dept | 2378543 |
| Electrical | Original | A | 11/3/2026 | DANIELG | DANIELG | | | Electrical | 2377938 |
| Monument Water | Original | A | 11/2/2026 | TOWNOFMON | TOWNOFMON | | jrigaud@tomgov.org | Monument Water | 2377445 |
| Plumbing | Original | A | 11/2/2026 | SHANEN | SHANEN | | | Plumbing | 2377384 |
| Construction | Original | D | 11/2/2026 | DOUGC | DOUGC | IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2377353 |
| Enumeration | Original | A | 10/30/2026 | BECKYA | BECKYA | | | Enumeration | 2376993 |
| | Original | / | 10/30/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2376985 |
| | Original | / | 10/29/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2376590 |
| Submittal 3 | Original | / | 10/29/2026 | TREYW | TREYW | Submittal #3 | | Submittal 3 | 2376589 |
| Monument Water | Original | D | 7/6/2026 | TOWNOFMON | TOWNOFMON | Disapproved so that the applicant can resubmit for review with other departments when ready. | Rey Medina | Monument Water | 2330665 |
| Monument Zoning | Original | D | 7/6/2026 | TOWNOFMON | TOWNOFMON | Not yet through public hearing approval. | Rey Medina | Monument Zoning | 2330664 |
| Tri-Lakes Fire (CSFD) | Original | D | 10/1/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | chiptaylor | Tri-Lakes Fire (CSFD) | 2218320 |
| Tri-Lakes Hazmat (CSFD) | Original | D | 10/1/2025 | CSFIRE | CSFIRE | | chiptaylor | Tri-Lakes Hazmat (CSFD) | 2218319 |
| EPC Health Dept | Original | D | 9/26/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit PT1379 has expired as of 02/28/2024. To continue earthmoving operations, please reapply for a new permit online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. AM | Amanda Furno | EPC Health Dept | 2216353 |
| Energy | Original | D | 9/25/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2215983 |
| Plumbing | Original | A | 9/25/2025 | TCRIPPEN | TCRIPPEN | Approved | | Plumbing | 2215982 |
| Mechanical | Original | D | 9/25/2025 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2215855 |
| Electrical | Original | D | 9/25/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2215765 |
| Construction | Original | D | 9/24/2025 | DOUGC | DOUGC | Code Study Form // IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2215704 |
| Enumeration | Original | A | 9/23/2025 | AMY | AMY | | | Enumeration | 2214917 |
| Electronic Plan | Original | / | 9/23/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2214905 |
| Submittal 2 | Original | / | 9/22/2025 | QUINTONW | QUINTONW | Submittal #2 | | Submittal 2 | 2213879 |
| Monument Water | Original | D | 7/14/2025 | TOWNOFMON | TOWNOFMON | Awaiting Town Council Approval on August 4th. | bholtztom | Monument Water | 2183807 |
| Monument Zoning | Original | D | 7/14/2025 | TOWNOFMON | TOWNOFMON | Awaiting Town Council Approval on August 4th. | bholtztom | Monument Zoning | 2183806 |
| Tri-Lakes Fire (CSFD) | Original | D | 6/24/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | Jacob.Watson | Tri-Lakes Fire (CSFD) | 2176070 |
| Tri-Lakes Hazmat (CSFD) | Original | D | 6/24/2025 | CSFIRE | CSFIRE | See Fire Comments | Jacob.Watson | Tri-Lakes Hazmat (CSFD) | 2176069 |
| EPC Health Dept | Original | D | 6/16/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit PT1379 has expired as of 02/28/2024. To continue earthmoving operations, please reapply for a new permit online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. BR | brothrock | EPC Health Dept | 2171932 |
| Energy | Original | D | 6/11/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2170230 |
| Mechanical | Original | D | 6/11/2025 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2170229 |
| Electrical | Original | D | 6/10/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2169363 |
| Electronic Plan | Original | / | 6/10/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2169344 |
| Plumbing | Original | D | 6/10/2025 | SHANEN | SHANEN | P1: Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. All gas piping related items shall be on the mechanical plans.Remove ALL references to gas piping from the plumbing plans. P2: Construction review comments regarding occupancy/occupant load must be addressed to verify compliance with section 403.1. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. See highlighted sections on clouded additional requirements for 2021 IECC block. P4: Water service location does not match the utility plan. Building drain locations does not match the utility plan. Outdoor trench drain and oil separator not shown on the utility plan. Outdoor trench drain must discharge to the storm sewer. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. P5: Water heater detail must show compliance with 2021 IECC section 404.3. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2169135 |
| Elevators | Original | N | 6/9/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2169107 |
| Construction | Original | D | 6/9/2025 | DOUGC | DOUGC | Accessibility // Life Safety Plan // IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2168891 |
| Energy | Original | / | 6/9/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2168817 |
| Electronic Plan | Original | / | 6/9/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2168741 |
| Enumeration | Original | A | 6/9/2025 | AMY | AMY | The tax schedule number on the Code Study form was added for you and is related to the property. This can be found on the El Paso County Assessor's database above the address. | | Enumeration | 2168530 |
| Electronic Plan | Original | / | 6/9/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2168497 |
| Waste Water Div | Original | / | 5/12/2025 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2157513 |
| Energy | Original | / | 5/12/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2157512 |
| Floodplain | Original | N | 5/12/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7135006001) | | Floodplain | 2157510 |