Electrical | Original | D | 6/3/2025 | BERTHA | BERTHA | Provide compliance with 230.70(A)(1)
Where applicable, Daylight Zones must be shown on the plans per C405.2.4.2 through C405.2.4.4. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2166465 |
CSU Waste Water | Original | D | 6/3/2025 | CSUREVIEW | CSUREVIEW | Utility Service Plan (USP) provides a 6" sanitary service stub. The plumb plans (P1.1) show a 4" service exiting the building. Provide clarity on either the USP or plumbing plans as to where the 6"x4" reducer will be located, inside or outside the building. CJS | cjsavage | CSU Waste Water | 2166107 |
CSU Water | Original | D | 6/3/2025 | CSUREVIEW | CSUREVIEW | Requires approval of the Commercial Water Meter Sizing Form.
Plumbing sheet P5.0: Meter detail provides conflicting information. 4" riser reduces to 3" at the 90° bend, then continues as 3" to a 2" meter. Per detail B1-6 the meter loop will reduce to 2" via a threaded tap on the 3" blind flange right after the 90° bend. Remove non-standard meter entry detail and replace with the applicable CSU standard detail. CJS | cjsavage | CSU Water | 2166092 |
Gas/Elec. Utils | Original | A | 6/3/2025 | CSUREVIEW | CSUREVIEW | Approved development plan provided with permit set. CJS | cjsavage | Gas/Elec. Utils | 2166078 |
EPC Health Dept | Original | D | 6/3/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit PT1272 has expired as of 08/20/23. To continue earthmoving operations, please reapply for a new permit online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/.
New retail food establishment plan review required (not approved by BR in 2023). Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/retail-food/retail-food-establishments/. Please email application and all required documents to heaenvironmental@elpasoco.com.
For questions, contact Environmental Health at 719-578-3199 option 3. AB | abrannon | EPC Health Dept | 2166046 |
Plumbing | Original | D | 6/3/2025 | SHANEN | SHANEN | P0.1: Piping insulation material schedule must include material (fiberglass, elastomeric foam, etc.) and manufacturer. P4.0: SH-1 and SH-2 appear to be mislabeled per fixture schedule. Clarify. Controls and hand showers shall comply with ICC A117.1-2017 section 608.4. P6.0: SH-1 and SH-2 appear to be mislabeled on sheet P4.0. Clarify. Water heater schedule must show efficiency requirements are met per section C404.2. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2165908 |
CSU Contract Admin. | Original | D | 6/3/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate. CWMSF was attached, but requires more information.
AMS | ASweet | CSU Contract Admin. | 2165877 |
Electronic Plan | Original | / | 6/3/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2165862 |
Elevators | Original | N | 6/2/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2165816 |
CO Springs DRE | Original | D | 6/2/2025 | MAMBUUL | MAMBUUL | 1. Please upload recorded plat to permit. 2. Need to provide financial assurances for public and private improvements prior to building permit approval. No CDI fees due per approval letter. | | CO Springs DRE | 2165722 |
Zoning/Planning | Original | / | 6/2/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2165682 |
Construction | Original | D | 6/2/2025 | BPHILLIPS | BPHILLIPS | Life safety plan, wood in IIB construction. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2165677 |
Electronic Plan | Original | / | 5/29/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2164125 |
Enumeration | Original | D | 5/22/2025 | BRENT | BRENT | Include a detailed site plan in the Architectural plan pages. Show the elevations for the trash enclosure in the architectural plan pages. Trash enclosures over 7 feet in height will require a separate address and building permit. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2162333 |
Electronic Plan | Original | / | 5/22/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2162302 |
Energy | Original | / | 5/22/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2161987 |
Floodplain | Original | N | 5/22/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6220201035) | | Floodplain | 2161986 |