Palmer Lake Fire | Original | D | 8/27/2025 | PLFIRE | PLFIRE | Smoke detector locations and emergency lighting not found on provided plans. | Palmer Lake FD | Palmer Lake Fire | 2203850 |
Palmer Lake Waste Water | Original | A | 8/21/2025 | PLSAN | PLSAN | | becky.orcutt@plsd.or | Palmer Lake Waste Water | 2200306 |
Palmer Lake Waste Water | Original | A | 8/21/2025 | PLSAN | PLSAN | | becky.orcutt@plsd.or | Palmer Lake Waste Water | 2200305 |
Palmer Lake Waste Water | Original | A | 8/21/2025 | PLSAN | PLSAN | | becky.orcutt@plsd.or | Palmer Lake Waste Water | 2200304 |
Palmer Lake Waste Water | Original | A | 8/21/2025 | PLSAN | PLSAN | | becky.orcutt@plsd.or | Palmer Lake Waste Water | 2200303 |
Energy | Original | D | 7/29/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2190444 |
Electrical | Original | D | 7/29/2025 | DANIELG | DANIELG | Pending elevator review. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2190443 |
Electronic Plan | Original | / | 7/29/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2190435 |
Plumbing | Original | D | 7/29/2025 | SHANEN | SHANEN | P001: Construction review comments regarding occupant load and ICC A117.1-2017 must be addressed. Provide water heater minimum performance (energy factor/thermal efficiency) see table C404.2. P111: Provided civil plans do not show the building drain/sewer location or sizing. Elevator review comments must be addressed. Elevator sump discharge shall comply with section 301.6. Show compliance with chapter 9 throughout. P112: Show compliance with chapter 9 throughout. P111A: ST-12 is for residential use only per Amtrol website. Shower controls and hand shower location must comply with ICC (ANSI) A117.1-2017 section 608.4 Controls and hand showers. Shower head locations must comply with Colorado state amendments to 2021 IPC. Added section 421.7. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2190317 |
Mechanical | Original | D | 7/29/2025 | TCRIPPEN | TCRIPPEN | Disapproved:elevator machine room requires an independent source of natural or mechanical ventilation or HVAC. need elevator shop drawings to determine requirements * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2190295 |
Elevators | Original | D | 7/28/2025 | ROBERTV | ROBERTV | See Sheets: A6.2, M112, E111, E111.2, E121, E121.2, P111 . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2190271 |
EPC Health Dept | Original | D | 7/23/2025 | HEALTHDEPT | HEALTHDEPT | Water recreation plan review required for public or semi-public pool and/or spa and supporting facilities. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/public-pools-spa/. Please email application and all required documents to heaenvironmental@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. BR | brothrock | EPC Health Dept | 2188191 |
Construction | Original | D | 7/21/2025 | JUSTINL | JUSTINL | Building does not appear to work as a V-B, non-sprinkled 3 story B occupancy. Missing IECC document for building thermal envelope. See architectural plans for remaining review comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2187268 |
Energy | Original | / | 7/21/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2187187 |
Electronic Plan | Original | / | 7/21/2025 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Electronic Plan | 2186937 |
Floodplain | Original | N | 7/21/2025 | KEITH | KEITH | | | Floodplain | 2186713 |
Waste Water Div | Original | / | 7/1/2025 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2178610 |
Energy | Original | / | 7/1/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2178609 |
Floodplain | Original | / | 7/1/2025 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 7108100016) | | Floodplain | 2178608 |