Energy | Original | D | 7/12/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2183684 |
Electrical | Original | D | 7/12/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2183683 |
Mechanical | Original | D | 7/11/2025 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2183497 |
City Engr | Original | D | 7/10/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan in the electronic building permit set. | | City Engr | 2182940 |
Plumbing | Original | D | 7/9/2025 | SHANEN | SHANEN | CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, grease interceptor location, etc. UR1 must be supplied with 3/4"CW per fixture schedule and watter piping system calculations. 3/4"CW is undersized to serve UR1 and WC1 per water piping system calculations. Provide sizing for roof drain conductors, downspouts and overflow scuppers. Provide gpm and/or square footage served by components of the roof drain system.All required roof drainage information (thru wall scupper opening dimensions, conductor head dimensions, overflow opening dimensions, gpm/square footage served, etc.) is not provided on architectural sheet A2.07. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2181766 |
Elevators | Original | N | 7/8/2025 | ANDREAL | ANDREAL | No conveyance in this scope of work. | | Elevators | 2181765 |
EPC Health Dept | Original | D | 7/8/2025 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review is in process and not yet approved. If your assigned plan reviewer has questions, they will contact you directly. For questions, contact Environmental Health at 719-578-3199 option 3. TG | tguerrero | EPC Health Dept | 2181732 |
CO Springs DRE | Original | D | 7/8/2025 | MAMBUUL | MAMBUUL | 1. Please upload approved development plans stamped by land use review to permit. Development plans are currently in review with land use review. 2. Please upload recorded plat to permit. 3. Please upload final landscape and irrigation plan sets to permit stamped by land use review. 4. Upon issuance of approval letter from land use review CDI fees may be due, fees must be paid prior to building permit approval. Contact DREplanninginfo@coloradosprings.gov to pay fees. 5. Need to provide financial assurances for public and private improvements prior to building permit approval. | | CO Springs DRE | 2181654 |
Zoning/Planning | Original | / | 7/8/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2181648 |
CSU Contract Admin. | Original | D | 7/8/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires submittal and approval of Commercial Water Meter Sizing Form (CWMSF) and payment of development charges/fees. CWMSF available at https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf. Contact Customer Contract Administration at 719-668-8111 for more information. JMD | jdemello | CSU Contract Admin. | 2181611 |
CSU Water | Original | D | 7/8/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. mjg | mgackle | CSU Water | 2181513 |
CSU Waste Water | Original | D | 7/8/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. mjg | mgackle | CSU Waste Water | 2181511 |
Gas/Elec. Utils | Original | D | 7/8/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. mjg | mgackle | Gas/Elec. Utils | 2181510 |
Construction | Original | D | 7/8/2025 | CHRISTINEH | CHRISTINEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2181466 |
Electronic Plan | Original | / | 7/7/2025 | CHRISTINEH | CHRISTINEH | In Current Review by CHRISTINEH | | Electronic Plan | 2180954 |
Enumeration | Original | A | 7/7/2025 | BECKYA | BECKYA | | | Enumeration | 2180937 |
Energy | Original | / | 7/2/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2179887 |
Floodplain | Original | N | 7/2/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6419308029) | | Floodplain | 2179886 |