Energy | Original | D | 8/21/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2200721 |
Electrical | Original | D | 8/21/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2200720 |
EPC Health Dept | Original | N | 8/18/2025 | HEALTHDEPT | HEALTHDEPT | Not applicable. AB | abrannon | EPC Health Dept | 2199101 |
CO Springs Fire | Original | D | 8/18/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | Jacob.Watson | CO Springs Fire | 2199064 |
CO Springs Hazmat | Original | D | 8/18/2025 | CSFIRE | CSFIRE | See Fire Comments | Jacob.Watson | CO Springs Hazmat | 2199062 |
Mechanical | Original | A | 8/13/2025 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 2196862 |
CSU Water | Original | N | 8/11/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. No new water service outside of building. Backflow okay.MDA | malcuran | CSU Water | 2196123 |
CSU Waste Water | Original | N | 8/11/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. No new wastewater service outside of building. MDA | malcuran | CSU Waste Water | 2196122 |
Plumbing | Original | D | 8/11/2025 | SHANEN | SHANEN | Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Show drainage and water piping points of connection and sizing at each point of connection. Provide required water pipe size analysis data, see 2021 IPC appendix E. ST-5 is for residential use only per manufacturer. 1/2"CW is undersized to serve downstream fixtures. All condensate piping and gas piping related items shall be on the mechanical plans. Remove ALL references to condensate piping and gas piping from the plumbing plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2196059 |
Construction | Original | D | 8/11/2025 | BPHILLIPS | BPHILLIPS | Occupant load, accessibility, demo plan * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2196015 |
Electronic Plan | Original | / | 8/8/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2195299 |
Enumeration | Original | D | 8/6/2025 | AMY | AMY | The permit history for this building is dated. Please provide the separation of space per tenant along with the addressing in use for each, on page A10-00. Please do a site check to verify this information from the outside of the building. The tax schedule number is required on the Code Study form. This information can be found above the address to the property above the address on the El Paso County Assessor’s website. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2194321 |
Electronic Plan | Original | / | 8/6/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2194173 |
Energy | Original | / | 8/5/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2193988 |
Floodplain | Original | N | 8/5/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6308001009) | | Floodplain | 2193986 |