CO Springs DRE | Original | D | 9/18/2025 | SSADLER | SSADLER | Upload the approved stamped development plan and the approval letter. Upload the final landscaping and irrigation plans. Financial assurances may need to be posted. CDI fees may be owed. | | CO Springs DRE | 2212952 |
Mechanical | Original | D | 9/17/2025 | TREVORH | TREVORH | Disapproved;Need to see construction review comments addressed with regards to Occupant load and the accessibility elements. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2212195 |
CSU Water | Original | D | 9/16/2025 | CSUREVIEW | CSUREVIEW | Approved City Development Plan must be attached to the permit set. Add note on plan to confirm if only interior pluming work and no exterior plumbing work proposed. Contact Utilities Development Services at 719-668-8259 with any questions.MDA | malcuran | CSU Water | 2211799 |
CSU Waste Water | Original | D | 9/16/2025 | CSUREVIEW | CSUREVIEW | Approved City Development Plan must be attached to the permit set. Add note on plan to confirm if only interior pluming work and no exterior plumbing work proposed. Contact Utilities Development Services at 719-668-8259 with any questions.MDA | malcuran | CSU Waste Water | 2211798 |
Plumbing | Original | D | 9/16/2025 | SHANEN | SHANEN | Show DWV and water distribution piping on the main floor plan. Show piping to the point of connection and show pipe sizing at the point of connection. 3/4"C.W. is undersized to serve downstream fixtures. Heated water supply piping shall comply with 2021 IECC section C404.5.1. Perimeter drains are not reviewed by plumbing plan review. Remove all references to the perimeter drainage system from the plumbing plans. Remove all references to residential codes. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2211293 |
Zoning/Planning | Original | / | 9/16/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2211279 |
Construction | Original | D | 9/15/2025 | DOUGC | DOUGC | Accessibility // Sprinklers // Occupant load * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2211213 |
Electronic Plan | Original | / | 9/15/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2210920 |
Enumeration | Original | D | 9/11/2025 | BECKYA | BECKYA | Provide a site plan showing location of building/addition, show full lot, surrounding streets, all buildings with current addressing, and highlight the area of work. Enumerations does not approve site plans in Development or Civil Plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2209683 |
Electronic Plan | Original | / | 9/11/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2209677 |
| Original | / | 9/11/2025 | SYSTEM | SYSTEM | Plan Review fees paid 09/11/2025 for plan submitted 09/10/2025. Submit Date updated to now. Plan now open for review. | | | 2209566 |
Energy | Original | / | 9/10/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2209277 |
Floodplain | Original | N | 9/10/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7412108027) | | Floodplain | 2209276 |