| Mechanical | Original | D | 1/6/2026 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2253629 |
| Electronic Plan | Original | / | 1/5/2026 | DALEH | DALEH | In Current Review by DALEH | | Electronic Plan | 2253476 |
| Electronic Plan | Original | / | 1/5/2026 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2253024 |
| EPC Health Dept | Original | N | 12/31/2025 | HEALTHDEPT | HEALTHDEPT | Not applicable. Per contact, Chris Jarc, no OWTS is associated with this project. AB | abrannon | EPC Health Dept | 2252578 |
| CO Springs DRE | Original | D | 12/31/2025 | SSADLER | SSADLER | Upload the approved and stamped development plan. Upload the approval letter Upload the final approved and stamped landscaping and irrigation plans. Upload the final recorded plat. City Wide Impact fees may be owed. Financial assurances for all private improvements must be posted. | | CO Springs DRE | 2252502 |
| CO Springs Fire | Original | D | 12/31/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | Jacob.Watson | CO Springs Fire | 2252476 |
| CO Springs Hazmat | Original | D | 12/31/2025 | CSFIRE | CSFIRE | See Fire Comments | Jacob.Watson | CO Springs Hazmat | 2252474 |
| Plumbing | Original | D | 12/31/2025 | SHANEN | SHANEN | Preliminary review. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Provide plumbing plans that comply with PPRBD commercial plumbing plan review requirements. See link: https://www.pprbd.org/File/ByAlias/PlumbingReview Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Provide address on all plumbing sheets. F occupancy with an occupant load of 14 requires compliance with section 403.1. All gas piping, condensate piping, hydronic and HVAC related items shall be on the mechanical plans. Remove ALL references to these systems from the plumbing plans. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Provide schedules, details, isometrics, etc. that apply to the current scope only. Elevator sump discharge must comply with section 301.6. Provide code section that supports discharging a hand sink through an indirect waste connection. Provide the plumbing floor plans that are associated with sheet PL7.10 isometric drawings or provide only the isometric drawings that apply to the current scope. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. Show water service extending a minimum of 30 inches beyond the exterior walls. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2252394 |
| Zoning/Planning | Original | / | 12/31/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2252392 |
| CSU Contract Admin. | Original | D | 12/30/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 to discuss charges/fees and request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
BS | bschifferstein | CSU Contract Admin. | 2252371 |
| CSU Water | Original | D | 12/30/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. PSD | PDosch | CSU Water | 2252368 |
| CSU Waste Water | Original | D | 12/30/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. PSD | PDosch | CSU Waste Water | 2252366 |
| Gas/Elec. Utils | Original | D | 12/30/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. PSD | PDosch | Gas/Elec. Utils | 2252365 |
| City Engr | Original | D | 12/30/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan and a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set. (Project Dox #STM-REV25-1056) | | City Engr | 2252361 |
| Elevators | Original | N | 12/30/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2252356 |
| Construction | Original | D | 12/30/2025 | DOUGC | DOUGC | CSF // Life Safety Plan // IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2252350 |
| Energy | Original | / | 12/30/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2252104 |
| Electronic Plan | Original | / | 12/30/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2251951 |
| Floodplain | Original | N | 12/29/2025 | BECKYA | BECKYA | | | Floodplain | 2251822 |
| Enumeration | Original | D | 12/29/2025 | BECKYA | BECKYA | Provide an Architectural Site plan in the Architectural Plans. Show all addressing for all buildings for this project and highlight area of work. Enumerations does not approve Civil or Development plans.
Since this area is being platted, Enumerations will not approve plans for this project until the Final Plat has been recorded. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2251819 |
| Electronic Plan | Original | / | 12/29/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2251792 |
| | Original | / | 12/29/2025 | SYSTEM | SYSTEM | Plan Review fees paid 12/29/2025 for plan submitted 12/23/2025. Submit Date updated to now. Plan now open for review. | | | 2251781 |
| Energy | Original | / | 12/23/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2251058 |