| Black Forest Fire (CSFD) | Original | A | 6/21/2026 | BLKFSTFIRE | BLKFSTFIRE | Black Forest Fire Rescue has reviewed the submitted plans for the proposed change of occupancy and interior remodel located at 5490 Burgess Road. Based on the plans provided, the project consists of a change of use from a residential occupancy to an Educational (Group E) occupancy with an occupant load of 153 persons.
Fire apparatus access shall be maintained in accordance with IFC Section 503. Approved address numbering shall be installed and maintained in accordance with IFC Section 505. Any modifications to site access, building layout, occupant load, fire protection systems, or egress components shall be submitted for additional review.
This approval is based on the submitted scope of work and does not authorize any future additions, commercial cooking operations, hazardous materials, fuel-fired equipment, or other systems requiring separate permits and approvals. | Flucas | Black Forest Fire (CSFD) | 2324394 |
| Energy | Original | A | 6/5/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2317284 |
| Mechanical | Original | A | 6/5/2026 | TREVORH | TREVORH | Approved; | | Mechanical | 2317283 |
| Construction | Original | A | 6/4/2026 | BRIANB | BRIANB | | | Construction | 2316679 |
| | Original | / | 5/29/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2314134 |
| | Original | / | 5/29/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2314125 |
| Submittal 3 | Original | / | 5/29/2026 | QUINTONW | QUINTONW | Submittal #3 | | Submittal 3 | 2314124 |
| Black Forest Fire (CSFD) | Original | D | 4/4/2026 | BLKFSTFIRE | BLKFSTFIRE | Black Forest Fire Protection District has reviewed the submitted Commercial Change of Occupancy / Interior Remodel (542) for a school use and revisions are required for fire and life safety compliance. Based on the proposed Group E occupancy and occupant load of approximately 138, an automatic fire sprinkler system appears to be required per IFC/IBC 903.2.3; provide justification if not provided. A compliant manual fire alarm and notification system is required per IFC 907.2.3. Corridor rating is not justified; provide compliance with IBC 1020.2 or revise. An accessible route to all occupied spaces is not provided and must comply with IBC Chapter 11. Fire apparatus access shall comply with IFC 503, including access dimensions and turnaround. The proposed 30,000-gallon cistern requires fire flow analysis per IFC Appendix B and NFPA 1142. Provide Knox Box per IFC 506 and clarify egress components per IBC Chapter 10. Resubmit with corrections. | Flucas | Black Forest Fire (CSFD) | 2288981 |
| Energy | Original | D | 4/2/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2288442 |
| Mechanical | Original | D | 4/2/2026 | TREVORH | TREVORH | disapproved; Need to see clarification on sun room/class room from construction review comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2288441 |
| Construction | Original | D | 4/1/2026 | BRIANB | BRIANB | See sheets A2.1 and A7.1 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2287818 |
| Enumeration | Original | N | 3/31/2026 | AMY | AMY | The address on the MEP pages was not correct. They have been corrected for you. If these pages get changed out, please correct the address on all pages. | | Enumeration | 2287196 |
| Electronic Plan | Original | / | 3/31/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2287176 |
| Submittal 2 | Original | / | 3/31/2026 | MELISSAF | MELISSAF | Submittal #2 | | Submittal 2 | 2286865 |
| Black Forest Hazmat (CSFD) | Original | N | 2/18/2026 | CSFIRE | CSFIRE | | phil.valdez | Black Forest Hazmat (CSFD) | 2268201 |
| Energy | Original | D | 2/11/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2265704 |
| Mechanical | Original | D | 2/11/2026 | TREVORH | TREVORH | Disapproved; How is classroom 4 & 5 complying with the 2021 IECC section 402.5.11 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2265703 |
| Black Forest Fire (CSFD) | Original | D | 2/9/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | Black Forest Fire (CSFD) | 2264851 |
| Construction | Original | D | 2/4/2026 | BRIANB | BRIANB | See G0.2 / A0.1 / A2.1 / A3.1 / S1 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2263444 |
| Enumeration | Original | D | 1/26/2026 | AMY | AMY | After further review this single story structure is 5484 which is this plan. 5490 Burgess Road is closer to the main road way. Change all pages of this plan to the correct address. Label each structure as to what their address is on the site plan. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2259831 |
| Electronic Plan | Original | / | 1/26/2026 | BRIANB | BRIANB | In Current Review by BRIANB | | Electronic Plan | 2259698 |
| Enumeration | Original | N | 12/29/2025 | AMY | AMY | | | Enumeration | 2251646 |
| Electronic Plan | Original | / | 12/29/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2251625 |
| | Original | / | 12/29/2025 | SYSTEM | SYSTEM | Plan Review fees paid 12/29/2025 for plan submitted 12/26/2025. Submit Date updated to now. Plan now open for review. | | | 2251562 |
| Waste Water Div | Original | / | 12/26/2025 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2251365 |
| Water Division | Original | / | 12/26/2025 | SYSTEM | SYSTEM | You will need to contact Water Division department for approval prior to permit. This department will not review the plan electronically. | | Water Division | 2251364 |
| Energy | Original | / | 12/26/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2251363 |
| Floodplain | Original | N | 12/26/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6213000037) | | Floodplain | 2251362 |