| Energy | Original | A | 4/21/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2295901 |
| Electrical | Original | A | 4/21/2026 | DANIELG | DANIELG | | | Electrical | 2295900 |
| Mechanical | Original | A | 4/20/2026 | TREVORH | TREVORH | Approved; | | Mechanical | 2295434 |
| | Original | / | 4/20/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2295024 |
| | Original | / | 4/20/2026 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2295016 |
| Submittal 3 | Original | / | 4/20/2026 | MELISSAF | MELISSAF | Submittal #3 | | Submittal 3 | 2295015 |
| Energy | Original | D | 4/17/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2294817 |
| Electrical | Original | D | 4/17/2026 | DANIELG | DANIELG | Service conductors are undersized. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2294816 |
| Mechanical | Original | D | 4/8/2026 | TREVORH | TREVORH | Disapproved; Need to provide the Mechanical COM check. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2290295 |
| Construction | Original | N | 4/7/2026 | DOUGC | DOUGC | | | Construction | 2289914 |
| Submittal 2 | Original | / | 4/7/2026 | QUINTONW | QUINTONW | Submittal #2 | | Submittal 2 | 2289867 |
| Energy | Original | D | 3/26/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2285402 |
| Electrical | Original | D | 3/26/2026 | BERTHA | BERTHA | Provide conduit/conductor size, type CU or AL and quantity beginning at the utility transformer to include all conductors in the chain of supply for the electrical equipment in the scope of work . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2285401 |
| Mechanical | Original | D | 3/16/2026 | TREVORH | TREVORH | Disapproved; Need to provide the MECHANICALcomCheckProvide the Refrigeration Calculations for the split systeminclude in schedules the Refrigeration type for all equipment containing Refrigeration * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2280544 |
| Gas/Elec. Utils | Original | A | 3/16/2026 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions.MDA | malcuran | Gas/Elec. Utils | 2280337 |
| Electronic Plan | Original | / | 3/13/2026 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2280016 |
| Construction | Original | N | 3/13/2026 | DOUGC | DOUGC | Mechanical and Electrical ONLY | | Construction | 2279970 |
| Electronic Plan | Original | / | 3/13/2026 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2279954 |
| Enumeration | Original | N | 2/20/2026 | AMY | AMY | | | Enumeration | 2268818 |
| Electronic Plan | Original | / | 2/20/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2268793 |
| | Original | / | 2/19/2026 | SYSTEM | SYSTEM | Plan Review fees paid 02/19/2026 for plan submitted 02/19/2026. Submit Date updated to now. Plan now open for review. | | | 2268678 |
| Energy | Original | / | 2/19/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2268675 |
| Floodplain | Original | N | 2/19/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6408422010) | | Floodplain | 2268674 |