| CO Springs Fire | Original | D | 5/19/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | CO Springs Fire | 2309246 |
| CO Springs Hazmat | Original | D | 5/19/2026 | CSFIRE | CSFIRE | See fire comments | phil.valdez | CO Springs Hazmat | 2309244 |
| CO Springs DRE | Original | D | 5/19/2026 | SSADLER | SSADLER | Plans are approved once CDI fees are collected. Contact Charla at charla.hudspeth@coloradosprings.gov
All FBZ approvals are on file. The proposed plans are consistent with the FBZ approved plan set. | | CO Springs DRE | 2309168 |
| Energy | Original | D | 5/15/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2307994 |
| Mechanical | Original | D | 5/15/2026 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2307993 |
| City Engr | Original | A | 5/15/2026 | HVO | HVO | A Geological Hazard report or waiver is not required. | | City Engr | 2307932 |
| Zoning/Planning | Original | / | 5/14/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2307705 |
| Electrical | Original | D | 5/14/2026 | BERTHA | BERTHA | Clarify scope of work. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2307663 |
| CSU Water | Original | D | 5/14/2026 | CSUREVIEW | CSUREVIEW | A Utility Service Plan may be required for this project. Contact Utilities Development Services at (719) 668-8259 to discuss requirements. mjg | mgackle | CSU Water | 2307657 |
| CSU Waste Water | Original | D | 5/14/2026 | CSUREVIEW | CSUREVIEW | A Utility Service Plan may be required for this project. Contact Utilities Development Services at (719) 668-8259 to discuss requirements. mjg | mgackle | CSU Waste Water | 2307656 |
| Gas/Elec. Utils | Original | D | 5/14/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan must be attached to the permit set if required. Contact Utilities Development Services at 719-668-8259 with any questions. mjg | mgackle | Gas/Elec. Utils | 2307653 |
| Construction | Original | D | 5/14/2026 | MATTHEWA | MATTHEWA | Clarify scope of work // Interior/exterior remodel and addition * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2307619 |
| Electrical | Original | D | 5/13/2026 | BERTHA | BERTHA | Clarify scope of work Exterior remodel only . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2306708 |
| Electronic Plan | Original | / | 5/13/2026 | MATTHEWA | MATTHEWA | In Current Review by MATTHEWA | | Electronic Plan | 2306701 |
| Plumbing | Original | D | 5/8/2026 | SHANEN | SHANEN | Address is 531 S Weber St. per plan label and architectural plans. All backgrounds must match per PPRBD plan review requirements. Suite 130 plumbing fixtures and walls are not show on the architectural floor plans. Provide 21 IPC code tables. Water service entry location does not match referenced civil plans. Building drain(s) and grease interceptor location does not match referenced civil plans. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, grease interceptor location, etc. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2304793 |
| Enumeration | Original | N | 5/6/2026 | BECKYA | BECKYA | | | Enumeration | 2303679 |
| | Original | / | 5/5/2026 | SYSTEM | SYSTEM | Plan Review fees paid 05/05/2026 for plan submitted 05/05/2026. Submit Date updated to now. Plan now open for review. | | | 2303347 |
| Energy | Original | / | 5/5/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2303290 |
| Floodplain | Original | N | 5/5/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6418415040) | | Floodplain | 2303289 |