| CO Springs Fire | Original | D | 10/12/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | CO Springs Fire | 2369984 |
| CO Springs Hazmat | Original | N | 10/12/2026 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2369943 |
| Energy | Original | D | 10/6/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2367776 |
| Mechanical | Original | D | 10/6/2026 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2367775 |
| CO Springs DRE | Original | A | 10/6/2026 | SSADLER | SSADLER | Commercial interior remodel approved. No changes to landscaping, footprint, or parking. No exterior changes approved with this permit. | | CO Springs DRE | 2367512 |
| Plumbing | Original | N | 10/5/2026 | SHANEN | SHANEN | All required plumbing fixtures are existing to remain. | | Plumbing | 2367108 |
| Zoning/Planning | Original | / | 10/2/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2366693 |
| Electrical | Original | D | 10/2/2026 | CONNERM | CONNERM | Lighting controls must be clearly shown and must comply with C405.2 (Interior)
Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10.
The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.” * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2366689 |
| CSU Water | Original | N | 10/2/2026 | CSUREVIEW | CSUREVIEW | No new water service outside of building.MDA | malcuran | CSU Water | 2366688 |
| CSU Waste Water | Original | N | 10/2/2026 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. MDA | malcuran | CSU Waste Water | 2366687 |
| Electronic Plan | Original | / | 10/2/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2366670 |
| Construction | Original | D | 10/2/2026 | JUSTINL | JUSTINL | See code study form and life safety plan for review comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2366642 |
| Electronic Plan | Original | / | 10/2/2026 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Electronic Plan | 2366425 |
| Enumeration | Original | D | 9/30/2026 | BRENT | BRENT | None of the buildings in this development use 4 digit suite numbers, all of them should be 3 digits. The suite number of the suite included in this plan is 120. Update all plan pages to show this suite number. Correct all suite numbers shown on the cover page to the correct 3 digit suite number. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2365549 |
| Electronic Plan | Original | / | 9/30/2026 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2365543 |
| | Original | / | 9/30/2026 | SYSTEM | SYSTEM | Plan Review fees paid 09/30/2026 for plan submitted 09/29/2026. Submit Date updated to now. Plan now open for review. | | | 2365236 |
| Energy | Original | / | 9/29/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2364563 |
| Floodplain | Original | N | 9/29/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6327121028) | | Floodplain | 2364562 |