Out to Review | Original | A | 7/20/2001 | RUSSELL | RUSSELL | Greg Pfiefer | | Out to Review | 143172 | Plumbing | Original | A | 7/20/2001 | RUSSELL | RUSSELL | | | Plumbing | 143173 | Mechanical | Original | A | 7/20/2001 | RUSSELL | RUSSELL | | | Mechanical | 143158 | Plumbing | Original | D | 7/20/2001 | RUSSELL | RUSSELL | Not all comments addressed from previous review | | Plumbing | 143176 | Mechanical | Original | D | 7/20/2001 | RUSSELL | RUSSELL | Not all comments addressed from previous review | | Mechanical | 143168 | Construction | Original | A | 7/20/2001 | TIMC | TIMC | | | Construction | 143149 | Out to Review | Original | A | 7/19/2001 | JAN | JAN | GREG PHIFER | | Out to Review | 143171 | Plumbing | Original | D | 7/3/2001 | RUSSELL | RUSSELL | Provide all water closets with open front seat, approval of water service entrance per city of Monument, wall cleanouts at drinking fountains, floor drain at 3-compartment sink per previously attached drawing, cold water piping to DF-1, sizing criteria for grease interceptor attached to both sets of drawings | | Plumbing | 143175 | Mechanical | Original | D | 7/3/2001 | RUSSELL | RUSSELL | Model Energy Code calculations with statement of compliance attached to both sets of drawings, Combustion air at mechanical room per '97 UMC Table 7-A and section 702.1 with exception, field labeling of units as to area served | | Mechanical | 143167 | Construction | Original | D | 6/29/2001 | TIMC | TIMC | Info shown on truss manf layout (labeling, hanger and tie-downs) must be combined with info shown on roof framing plan (headers, col's, etc...) into one drawing and must be stamed by engineer of record. 3 day recheck. | | Construction | 143151 | Zoning/Planning | Original | A | 6/28/2001 | KEN | KEN | 06-28-01 MJD | | Zoning/Planning | 143177 | Fire | Original | A | 6/28/2001 | KEN | KEN | 06-28-01 KAJ - trilakes | | Fire | 143154 | Health Dept. | Original | A | 6/28/2001 | KEN | KEN | 06-20-01 John James | | Health Dept. | 143156 | Construction | Original | / | 6/28/2001 | KEN | KEN | revised 06/28/01 | | Construction | 143148 | Out to Review | Original | A | 6/20/2001 | JOHNJ | JOHNJ | BILL BARTOLIC IS WALKING | | Out to Review | 143170 | Electrical | Original | A | 6/18/2001 | JERRY | JERRY | | | Electrical | 143152 | Out to Review | Original | A | 6/15/2001 | JERRY | JERRY | jerry | | Out to Review | 143169 | Plumbing | Original | D | 6/13/2001 | RUSSELL | RUSSELL | Provide location of meter and PRV at water service entrance, floor drain required at this location, funnel drain to floor drain not to exterior of building, if backflow preventer and meter assembly located more than 5 feet above floor, furnish with permanent platform per '97 UPC section 603.3.3, detail of grease interceptor required and sizing criteria, venting of discharge line from interceptor, venting of floor drains in furnace room per '99 PPRBC section 901.0 with exceptions, water closets to be elongated bowl with open front seat, direct connectio of 3-comp sink, and dishwasher if not undercounter type, waste, vent and water piping to drinking fountain location, | | Plumbing | 143174 | Mechanical | Original | D | 6/13/2001 | RUSSELL | RUSSELL | Provide Model Energy Code calculations with statement of compliance per '92 Model Energy Code, location of transfer air duct in relationship to rated corridor, cannot return air from a rated corridor, two combustion air openings required per '97 UMC table 7-A at furnace rooms, flue sizing per Gama tables and sizing per btuh's, flex duct shall be UL 181 class 0 or class 1, exhaust fans to be furnished with backdraft dampers, 1/4" mesh at openings screened for ventilation, Fire/Smoke dampers required at all duct penetrations at 1 hour occupancy separation, hood details per attached sheet, hood at dishwasher if not undercounter type, field labeling of units as to area served, | | Mechanical | 143166 | Construction | Original | D | 6/7/2001 | TIMC | TIMC | Trusses required to be designed for 85 mph wind speed, and each must be signed, dated and stamped by engineer. Provide manufacturer book/spec's and ICBO approval report for Kant-Sag hangers and tie-downs. Min 20' ROW required from front entrance to street. 1-hr occ sep required between kitchen and rest of building. See door schedule for missing ratings on doors. Info shown on truss manf layout (labeling, hanger and tie-downs) must be combined with info shown on roof framing plan (headers, col's, etc...) into one drawing and must be stamed by engineer of record. Trusses were not designed according to engineer of record requirements. Address other comments as noted on drawing set. 3 day recheck. | | Construction | 143150 | Health Dept. | Original | D | 5/15/2001 | JOHNJ | JOHNJ | 5-14-01 jrg {see stamp,final approval will be subject to h.d. inspection-a h.d. plan review is reccomended} | | Health Dept. | 143157 | Floodplain | Original | A | 5/11/2001 | JEANNINE | JEANNINE | | | Floodplain | 143155 | Enumeration | Original | A | 5/10/2001 | TESHA | TESHA | | | Enumeration | 143153 |
|
| |
|