Zoning/Planning | Original | A | 1/18/2006 | JEREMY | JEREMY | tk | | Zoning/Planning | 233525 |
Health Dept. | Original | A | 1/17/2006 | HEALTHDEPT | HEALTHDEPT | Approved as corrected in plan review dated 1/17/06. +Please contact LP at (719) 578-3132 with questions. | | Health Dept. | 233502 |
Mechanical | Original | A | 1/11/2006 | RUSSELL | RUSSELL | | | Mechanical | 233505 |
Mechanical | Original | / | 1/10/2006 | SHELLEY | SHELLEY | | | Mechanical | 233504 |
Out to Review | Original | A | 12/29/2005 | ANGELA | ANGELA | LECIL RUSS 522-0500 | | Out to Review | 233517 |
Mechanical | Original | D | 12/29/2005 | RUSSELL | RUSSELL | Sheet GM1, still have not addressed previous red-line comment notes 2 & 3. hood reqmts at pan washers & hood reqmts at ovens | | Mechanical | 233506 |
Plumbing | Original | A | 12/29/2005 | KYE | KYE | | | Plumbing | 233519 |
Out to Review | Original | A | 12/27/2005 | JEANNINE | JEANNINE | back to mechanical. | | Out to Review | 233516 |
Floodplain | Original | A | 12/27/2005 | JEANNINE | JEANNINE | | | Floodplain | 233500 |
Enumeration | Original | A | 12/27/2005 | MARLENE | MARLENE | | | Enumeration | 233497 |
Out to Review | Original | A | 12/27/2005 | ANGELA | ANGELA | out to Phil Salo in building in Enumerations. | | Out to Review | 233515 |
Construction | Original | A | 12/19/2005 | TIMC | TIMC | | | Construction | 233493 |
Plumbing | Original | / | 12/15/2005 | JEREMY | JEREMY | | | Plumbing | 233518 |
Mechanical | Original | / | 12/15/2005 | JEREMY | JEREMY | | | Mechanical | 233503 |
Construction | Original | / | 12/15/2005 | JEREMY | JEREMY | | | Construction | 233492 |
Out to Review | Original | A | 11/22/2005 | JEREMY | JEREMY | Lecil Russ 522-0500 | | Out to Review | 233514 |
Plumbing | Original | D | 11/16/2005 | KYE | KYE | Remove old redlined sheets, leave loose for reference. P1: Need non potable water sign at HB and YH locations. P2: Need note requiring hot water piping to be insulated due to recirc system. Future bank DWV does not show on ISO, still unclear about note on plan for elbow turn out. Show water heater drain with minimum 1.25" drain. P4: Permanent sign stating "Nonpotable water do not drink" required at all hose bibb and yard hydrant locations. HB5 requires backflow protection. Still need Health Department approval prior to plumbing sign off. | | Plumbing | 233522 |
Mechanical | Original | D | 11/16/2005 | KYE | KYE | Remove all old redlined sheets, leave loose for reference. M2: Notes 1 & 2 for break and rest room outside air not rectified. M3: Still need note added to Rtu schedule stating "Balance report required at time of final HVAC inspection verifying accuracy of outside air as shown on schedules". MP2: Did not address comments. GP4: Did not address comments. GM1: Did not address comments 2 & 3. | | Mechanical | 233509 |
Water Division | Original | A | 11/8/2005 | JEREMY | JEREMY | rb 10-28-05 | | Water Division | 233524 |
Waste Water Div | Original | A | 11/8/2005 | JEREMY | JEREMY | rb 10-28-05 | | Waste Water Div | 233523 |
Fire | Original | A | 11/8/2005 | JEREMY | JEREMY | 10-28-05 | | Fire | 233499 |
Out to Review | Original | A | 11/4/2005 | OWEN | OWEN | Monday Plan Room 11-4-05 | | Out to Review | 233513 |
Construction | Original | D | 11/2/2005 | TIMC | TIMC | Comments from 1st review have not been addressed, no further review performed. | | Construction | 233495 |
Out to Review | Original | A | 10/27/2005 | MARLENE | MARLENE | Phil Salo | | Out to Review | 233512 |
Out to Review | Original | A | 10/11/2005 | OWEN | OWEN | david gray 303-770-5600 | | Out to Review | 233511 |
Electrical | Original | A | 10/10/2005 | JERRY | JERRY | ALL KITCHEN AREAS TO COMPLY WITH 210.8(B)(2) | | Electrical | 233496 |
Out to Review | Original | A | 10/6/2005 | JERRY | JERRY | JERRY | | Out to Review | 233510 |
Plumbing | Original | D | 10/5/2005 | KYE | KYE | P2: 1. Future tenants DWV rough is unclear as to location and purpose of 2" elbow at 10' AFF, horizontal vent height? Also not shown on DWV riser plan. 2. Due to hotwater recirculating line all hot water pipe mains on loopneed insulation. 3. Health Water and Waste Water approval required prior to plumbing sign off. 4. Provide wall cleanouts for allurinals. P3: 1. Public lavatory temperature maximum setting is 110 degrees. P4: 1. All hose thread connections must be provided with back flow protection. 2. Woodford model Y2 yard hydrant has a drain down below grade causing a backflow preventer to be installed on the line supplying the hydrant and a sign stating "Water is nonpotable do not drink, or use Woodford model S3 or S4H. 3. Carbonater back flow protected is required to be stinless steel. MP2: 1. Is auto shop restroom unisex? | | Plumbing | 233521 |
Plumbing | Original | D | 10/5/2005 | KYE | KYE | GP1: 1. Plumb 3 compartment sink and washing machines per attached detail. 2. FD3 shown on combination waste/vent system, specify which are 2" and which are 3" as some have 4" traps and some have 3" traps. GP2: 1. Dairy cooler trench drain detail needs a listed fitting connection to the trap tailpiece. GP3: 1. Combination waste/vent system not allowed on grease waste system, provide vents for all floor drains. 2. Vents for combination waste/vent systems must be 1/2 the cross sectional area of the drain it serves. 3. Note if FD3 is 2" or 3". GP4: 1. All hose thread connections require back flow protection. | | Plumbing | 233520 |
Mechanical | Original | D | 10/5/2005 | KYE | KYE | M1: Increase gas line to 1" for RTU 9,19,11. M3: 1. Provide balance report to inspector at time of final HVAC inspection that verifies OSA is as scheduled. 2. C02 setting may be no higher than 800 PPM per Pikes Peak Regional Building Code. 3. Even with C02 controlled modulation OSA is still inadequate per Table 403.3 2003 IMC. M2: 1. Using 1/2 duration for conference and break rooms the break room requires 319 cfm of OSA plus the OSA for the smoking breakroom is 1,260 that is transfered from the break room, total 1,579 of OSA. Rtu 33 is only supplying 200 cfm of OSA. 2. Rtu 31 supplying 10% OSA (30 cfm) to each restroom Table 403.3 IMC requires 75 cfm per W/C and urinal. 3. Provide 100 square inch transfer grill from laundry room to minimum 500 sq. ft. area formake up air. 4. Beauty shop requires 480 cfm of OSA, Rtu 7 only providing 175. Are they doing nails? | | Mechanical | 233508 |
Mechanical | Original | D | 10/5/2005 | KYE | KYE | MP1: 1. Gas connection details: Gas pipe must be installed so units can be removed with out disassembling gas pipe upstream of appliance shutoff. MP2: 1. Tire sales area OSA inadequate, also showing Rtu 27 with 900 cfm supply with return air openings of 2,700? 2. Total exhaust from auto garage is 18,800 no provisions for make up air ahown. GM1: 1. Top of type I hood may not be open/unprotected to space above ceilings. Needs shaft of fire wrap. 2. Provide information on pan washer, may require type II hood. 3. Type II hood required for oven with proving switch that keeps oven gas valve from energizing when exhaust fan is not operating. R3: 1. Provide amounts of R-404A being used. | | Mechanical | 233507 |
Construction | Original | D | 9/26/2005 | TIMC | TIMC | Min 20 psf wind loading required. Specify Pg and Pf roof loading. Plywood in nonbearing partitions required to be fire treated, not permitted in bearing walls. Specify quantity and types of chemicals/materials stored in auto center areas. Provide model energy code calcs and cert. No walk-thru. | | Construction | 233494 |
Zoning/Planning | Original | D | 9/7/2005 | OWEN | OWEN | tkq | | Zoning/Planning | 233526 |
Floodplain | Original | D | 9/1/2005 | JEANNINE | JEANNINE | To Constr. 9-7-05--og/Require approved address. | | Floodplain | 233501 |
Enumeration | Original | D | 9/1/2005 | MARLENE | MARLENE | Site Plan showing entire property and drive access required; also Legal Description. | | Enumeration | 233498 |