Out to Review | Original | A | 8/7/2007 | ANGELA | ANGELA | out to Jerry Parma 388-1667 | | Out to Review | 304201 |
Hazmat/High Pile | Original | N | 8/7/2007 | ANGELA | ANGELA | sm | | Hazmat/High Pile | 304191 |
Hazmat/High Pile | Original | A | 8/7/2007 | ANGELA | ANGELA | | | Hazmat/High Pile | 304190 |
Fire | Original | A | 8/7/2007 | ANGELA | ANGELA | smc | | Fire | 304186 |
Electrical | Original | A | 8/7/2007 | ANGELA | ANGELA | slb 8-7-7- | | Electrical | 304179 |
Out to Review | Original | A | 8/7/2007 | SHELBY | SHELBY | MIKE 332 2006 | | Out to Review | 304200 |
Electrical | Original | A | 8/7/2007 | SHELBY | SHELBY | | | Electrical | 304178 |
Electrical | Original | / | 8/7/2007 | | SHELBY | Location = Electrical by SHELBY | | Electrical | 304177 |
Mechanical | Original | A | 8/7/2007 | RUSSELL | RUSSELL | | | Mechanical | 304196 |
Plumbing | Original | A | 8/7/2007 | TCRIPPEN | TCRIPPEN | no spray both hand rud only | | Plumbing | 304209 |
Hazmat/High Pile | Original | / | 8/1/2007 | JEFFREY | JEFFREY | rbd not authorized to approve first time interior finish as LSP | | Hazmat/High Pile | 304188 |
Fire | Original | / | 8/1/2007 | JEFFREY | JEFFREY | rbd not authorized to approve first time interior finish as LSP | | Fire | 304184 |
Construction | Original | A | 8/1/2007 | JEFFREY | JEFFREY | given to karen | | Construction | 304173 |
Construction | Original | D | 7/27/2007 | JOHNJ | JOHNJ | Customer changed wall design at interior non bearing walls to a modular wall, customer had a ICC-ES sheet on it but a listing on the techical design data sheet not specific on combustability, needs to have tech. sheet marked with proper design and Arch. stamp and installation instructions for the design as it was not specified otherwise. | | Construction | 304174 |
Enumeration | Original | A | 7/16/2007 | MARLENE | MARLENE | | | Enumeration | 304181 |
Out to Review | Original | A | 7/16/2007 | HEATHER | HEATHER | Ron 388-1667 | | Out to Review | 304199 |
Finished Bin | Original | / | 7/12/2007 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 304183 |
Plan Coordinator | Original | / | 7/12/2007 | | GARYL | Location = Plan Coordinator by GARYL | | Plan Coordinator | 304207 |
Electrical | Original | D | 7/12/2007 | GARYL | GARYL | 1) SHOW FAULT CURRENT AT DISCONNECT 2) PARALLEL 3/0 ALU. NOT GOOD FOR 400AMPS, 3) SHOW FUSE TYPE AND SIZES 4) CHECK FUSING OF 400A FEEDING 200A PANELS. 5) 20A CIRCUIT NOT LARGE ENOUGH FOR 4800WATT DRYER, 6) NEED COMPLETE LIST OF EQUIPMENT SHOWING VOLT AMPS | | Electrical | 304180 |
Electrical | Original | / | 7/6/2007 | MINDY | MINDY | Given to JERRY by MINDY | | Electrical | 304176 |
Electrical | Original | / | 7/5/2007 | | MINDY | Location = Electrical by MINDY | | Electrical | 304175 |
Plan Coordinator | Original | / | 7/5/2007 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 304206 |
Mechanical | Original | D | 7/5/2007 | DALEH | DALEH | need to provide manufacturers data on spray booth see redlines on plans return redlines with next review no walk thru | | Mechanical | 304197 |
Mechanical | Original | / | 7/5/2007 | | TCRIPPEN | Location = Mechanical by TCRIPPEN | | Mechanical | 304195 |
Plumbing | Original | D | 7/5/2007 | TCRIPPEN | TCRIPPEN | 1-provide floor drian for wash room 2-provide manufacturs infomation on spray booth | | Plumbing | 304210 |
Mechanical | Original | / | 7/5/2007 | MINDY | MINDY | Given to TCRIPPEN by MINDY | | Mechanical | 304194 |
Plumbing | Original | / | 7/5/2007 | | MINDY | Location = Plumbing by MINDY | | Plumbing | 304208 |
Plan Coordinator | Original | / | 7/5/2007 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 304205 |
Mechanical | Original | / | 7/5/2007 | MINDY | MINDY | Given to RUSSELL by MINDY | | Mechanical | 304193 |
Mechanical | Original | / | 7/5/2007 | | MINDY | Location = Mechanical by MINDY | | Mechanical | 304192 |
Plan Coordinator | Original | / | 7/5/2007 | | TIMC | Location = Plan Coordinator by TIMC | | Plan Coordinator | 304204 |
Hazmat/High Pile | Original | A | 7/5/2007 | TIMC | TIMC | | | Hazmat/High Pile | 304189 |
Fire | Original | A | 7/5/2007 | TIMC | TIMC | | | Fire | 304185 |
Plan Coordinator | Original | / | 7/5/2007 | | TIMC | Location = Plan Coordinator by TIMC | | Plan Coordinator | 304203 |
Construction | Original | A | 7/5/2007 | TIMC | TIMC | | | Construction | 304172 |
Construction | Original | / | 7/3/2007 | MINDY | MINDY | Given to TIMC by MINDY | | Construction | 304171 |
Construction | Original | / | 7/2/2007 | | MINDY | Location = Construction by MINDY | | Construction | 304170 |
Out to Review | Original | A | 6/29/2007 | MINDY | MINDY | Ron O'Neil 388-1667 | | Out to Review | 304198 |
Construction | Original | / | 6/20/2007 | | MINDY | Location = Construction by MINDY | | Construction | 304169 |
Zoning/Planning | Original | A | 6/20/2007 | MINDY | MINDY | 06/19/07 BUV | | Zoning/Planning | 304212 |
Floodplain | Original | A | 6/13/2007 | JEANNINE | JEANNINE | 509F, LOMR 05-08-0575P effective 08/23/2006 | | Floodplain | 304187 |
Zoning/Planning | Original | / | 6/13/2007 | | MARLENE | Location = Zoning/Planning by MARLENE | | Zoning/Planning | 304211 |
Plan Coordinator | Original | / | 6/13/2007 | | MARLENE | Location = Plan Coordinator by MARLENE | | Plan Coordinator | 304202 |
Enumeration | Original | D | 6/13/2007 | MARLENE | MARLENE | Provide legal Description on Site Plan and suite numbers on each side of this tenant space. | | Enumeration | 304182 |