Scanned/Finished Bin | Original | / | 3/11/2009 | | SHARON | Location = Scanned/Finished Bin by SHARON | | Scanned/Finished Bin | 402901 |
To Be Scanned Bin | Original | / | 3/11/2009 | | NELIDA | Location = To Be Scanned Bin by NELIDA | | To Be Scanned Bin | 402885 |
Mechanical | Original | A | 3/11/2009 | RUSSELL | RUSSELL | | | Mechanical | 402881 |
Plumbing | Original | A | 3/11/2009 | TCRIPPEN | TCRIPPEN | | | Plumbing | 402818 |
Out to Review | Original | / | 3/11/2009 | SHELBY | SHELBY | Mark 473 9590 | | Out to Review | 402795 |
Electrical | Original | A | 3/11/2009 | SHELBY | SHELBY | | | Electrical | 402793 |
Out to Review | Original | / | 1/7/2009 | MINDY | MINDY | Tom 475 8133 | | Out to Review | 395731 |
Finished Bin | Original | / | 12/30/2008 | | SHARON | Location = Finished Bin by SHARON | | Finished Bin | 395167 |
Fire | Original | A | 12/30/2008 | SHARON | SHARON | 12/30/08 jrm | | Fire | 395166 |
Fire | Original | / | 12/23/2008 | | SHARON | Location = Fire by SHARON | | Fire | 394806 |
Plan Coordinator | Original | / | 12/23/2008 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 394802 |
Electrical | Original | D | 12/23/2008 | SHELBY | SHELBY | load on panel EMDP2 exceeds panel ampacity | | Electrical | 394801 |
Electrical | Original | / | 12/23/2008 | SHARON | SHARON | Plan Reviewer = SHELBY by SHARON | | Electrical | 394663 |
Electrical | Original | / | 12/19/2008 | | MINDY | Location = Electrical by MINDY | | Electrical | 394397 |
Plan Coordinator | Original | / | 12/19/2008 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 394396 |
Plumbing | Original | D | 12/19/2008 | TCRIPPEN | TCRIPPEN | floor drains are for emergency use only , and shall not be located in concealed areas , waste receptor required , back flow protection required | | Plumbing | 394395 |
Plumbing | Original | / | 12/19/2008 | SHARON | SHARON | Plan Reviewer = TCRIPPEN by SHARON | | Plumbing | 394336 |
Plumbing | Original | / | 12/19/2008 | | SHARON | Location = Plumbing by SHARON | | Plumbing | 394308 |
Mechanical | Original | D | 12/18/2008 | DALEH | DALEH | need to provide refrig. calc's provide all new work in bold and show existing in light line weights verify scope of work area with sheet a-1 provide weights of all new equipment need to provide structural engineers letter return all red lines with next review | | Mechanical | 394295 |
Mechanical | Original | / | 12/18/2008 | MINDY | MINDY | Plan Reviewer = DALEH by MINDY | | Mechanical | 394235 |
Mechanical | Original | / | 12/18/2008 | | MINDY | Location = Mechanical by MINDY | | Mechanical | 394234 |
Mechanical | Original | / | 12/18/2008 | | MARY | Location = Mechanical by MARY | | Mechanical | 394174 |
Construction | Original | A | 12/18/2008 | SHELLEY | SHELLEY | | | Construction | 394166 |
Out to Review | Original | / | 12/18/2008 | MARLENE | MARLENE | Tom | | Out to Review | 394152 |
Out to Review | Original | / | 12/18/2008 | MARLENE | MARLENE | | | Out to Review | 394149 |
Floodplain | Original | A | 12/18/2008 | MARLENE | MARLENE | | | Floodplain | 394148 |
Floodplain | Original | / | 12/18/2008 | | MARLENE | Location = Floodplain by MARLENE | | Floodplain | 394146 |
Enumeration | Original | A | 12/18/2008 | MARLENE | MARLENE | | | Enumeration | 394145 |
Out to Review | Original | / | 12/18/2008 | MARY | MARY | TOM TO WALK | | Out to Review | 394143 |