Out to Review | Original | / | 10/1/2010 | SHELBY | SHELBY | Mike Seymore | | Out to Review | 477762 |
Electrical | Original | A | 10/1/2010 | SHELBY | SHELBY | Splice | | Electrical | 477760 |
Mechanical | Original | A | 9/3/2010 | RUSSELL | RUSSELL | Splice of mechanical sheet | | Mechanical | 474029 |
Scanned/Finished Bin | Original | / | 8/4/2010 | | REBECCA | Location = Scanned/Finished Bin by REBECCA | | Scanned/Finished Bin | 469706 |
To Be Scanned Bin | Original | / | 8/4/2010 | | JAN | Location = To Be Scanned Bin by JAN | | To Be Scanned Bin | 469666 |
CO Springs Fire | Original | A | 8/4/2010 | JAN | JAN | RCE 8-4-10 | | CO Springs Fire | 469665 |
Water Division | Original | A | 8/4/2010 | CSUREVIEW | CSUREVIEW | | mlwilliams | Water Division | 469632 |
Water Division | Original | D | 8/4/2010 | CSUREVIEW | CSUREVIEW | CS Fire Department approval of the RBD plans set is required prior to Water RBD approval by Utilities Development Services. | mlwilliams | Water Division | 469600 |
Construction | Original | A | 8/3/2010 | JAY | JAY | ok | | Construction | 469503 |
Mechanical | Original | A | 7/30/2010 | DALEH | DALEH | | | Mechanical | 469268 |
Out to Review | Original | / | 7/30/2010 | SHELBY | SHELBY | Mike 332 2006 | | Out to Review | 469257 |
Electrical | Original | A | 7/30/2010 | SHELBY | SHELBY | | | Electrical | 469256 |
Out to Review | Original | / | 7/29/2010 | KIM | KIM | terri 491-5711 | | Out to Review | 469095 |
Finished Bin | Original | / | 7/28/2010 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 468773 |
CO Springs DRE | Original | A | 7/28/2010 | MINDY | MINDY | 07/26/10 dmt | | CO Springs DRE | 468772 |
Plan Coordinator | Original | / | 7/28/2010 | | NELIDA | Location = Plan Coordinator by NELIDA | | Plan Coordinator | 468759 |
Water Division | Original | D | 7/28/2010 | CSUREVIEW | CSUREVIEW | CS Fire Department approval of the RBD plans set is required prior to Water RBD approval by Utilities Development Services. Provide information regarding meter size and location. | mlwilliams | Water Division | 468756 |
Waste Water Div | Original | A | 7/28/2010 | CSUREVIEW | CSUREVIEW | | mlwilliams | Waste Water Div | 468755 |
Gas/Elec. Utils | Original | A | 7/28/2010 | CSUREVIEW | CSUREVIEW | | mlwilliams | Gas/Elec. Utils | 468754 |
Hazmat | Original | N | 7/27/2010 | CSFIRE | CSFIRE | | csfdit | Hazmat | 468596 |
CSU Utilities | Original | / | 7/27/2010 | | CSFIRE | Location = CSU Utilities by CSFIRE | csfdit | CSU Utilities | 468595 |
CO Springs Fire | Original | D | 7/27/2010 | CSFIRE | CSFIRE | REFER TO ATTACHED REVIEW REPORT | csfdit | CO Springs Fire | 468594 |
Zoning/Planning | Original | / | 7/20/2010 | | MINDY | Location = Zoning/Planning by MINDY | | Zoning/Planning | 467623 |
Plan Coordinator | Original | / | 7/20/2010 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 467612 |
Plumbing | Original | A | 7/20/2010 | TCRIPPEN | TCRIPPEN | | | Plumbing | 467611 |
Plumbing | Original | / | 7/20/2010 | REBECCA | REBECCA | Plan Reviewer = TCRIPPEN by REBECCA | | Plumbing | 467601 |
Plumbing | Original | / | 7/20/2010 | | REBECCA | Location = Plumbing by REBECCA | | Plumbing | 467563 |
Plan Coordinator | Original | / | 7/20/2010 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 467548 |
Electrical | Original | D | 7/20/2010 | SHELBY | SHELBY | 1. Provide footprint of entire structure showing all existing and new service gear. 2. Remove parallel neutral from service lateral. 3. Provide complete one line for existing service involved in this scope of work. | | Electrical | 467547 |
Electrical | Original | / | 7/20/2010 | REBECCA | REBECCA | Plan Reviewer = SHELBY by REBECCA | | Electrical | 467481 |
Electrical | Original | / | 7/19/2010 | | REBECCA | Location = Electrical by REBECCA | | Electrical | 467289 |
Mechanical | Original | D | 7/19/2010 | DALEH | DALEH | Shell drawings appear to show two existing rtus what is going on with them ? capped, removed , abandoned, etc....... structural engineers letter for rtus exhaust fan 2 needs to be 150 cfm minimum o.s.a. to rtus with co2 sensors 20% see schedule to confirm btus on furnace isometric drawing basement level floor plan ? this is a finish need mechanical drawings and ventilation if basement is part of this tenant | | Mechanical | 467267 |
Mechanical | Original | / | 7/16/2010 | REBECCA | REBECCA | Plan Reviewer = DALEH by REBECCA | | Mechanical | 467224 |
Mechanical | Original | / | 7/16/2010 | | REBECCA | Location = Mechanical by REBECCA | | Mechanical | 467215 |
Plan Coordinator | Original | / | 7/16/2010 | | JAY | Location = Plan Coordinator by JAY | | Plan Coordinator | 467207 |
Construction | Original | D | 7/16/2010 | JAY | JAY | Code Study Form: RBD Records indicate Type V-B Construction and a Sprinklered Building / Occupant Load does not match plans / Exits provided = 3. ComCheck Form: See comments and adjust as necessary. RE: Sheet LSP1.1 - Provide all required information for Life Safety Plan as noted on sheet and on PPRBD website. RE: Sheet A1.1 - Rated Corridors are not required if building has sprinklers, otherwise provide UL Listing for all rated assemblies. See Plan for any additional comments. NO WALK | | Construction | 467206 |
Construction | Original | / | 7/16/2010 | JAY | JAY | Plan Reviewer = JAY by JAY | | Construction | 467169 |
Construction | Original | / | 7/16/2010 | | JAY | Location = Construction by JAY | | Construction | 467168 |
Out to Review | Original | / | 7/15/2010 | JEANNINE | JEANNINE | | | Out to Review | 466976 |
Floodplain | Original | N | 7/15/2010 | JEANNINE | JEANNINE | | | Floodplain | 466974 |
Enumeration | Original | A | 7/15/2010 | JEANNINE | JEANNINE | Site Plan included. | | Enumeration | 466973 |