Electrical | Splice 6/9/17 | A | 6/9/2017 | SHELBY | SHELBY | | | Electrical | 967985 |
Plumbing | Splice 6/9/17 | A | 6/9/2017 | TCRIPPEN | TCRIPPEN | new splice page | | Plumbing | 967958 |
Out to Review | Splice 6/9/17 | / | 6/9/2017 | BECKYA | BECKYA | | | Out to Review | 967951 |
Construction | Splice 5/23/17 | A | 6/1/2017 | DANM | DANM | Structural letter to address duct enclosure support and hole thru existing metal deck; architectural listed assembly for replacement of monocoat | | Construction | 965137 |
Electrical | Splice 5/23/17 | A | 5/31/2017 | BERTHA | BERTHA | Reapproved for removal of circ pump. | | Electrical | 964614 |
Plumbing | Splice 5/23/17 | A | 5/31/2017 | JUSTINC | JUSTINC | per Joel S. no circ. pump required | | Plumbing | 964606 |
Construction | Splice 5/23/17 | D | 5/31/2017 | DANM | DANM | Upon further review and inspector site visit it was determined that the pizza oven flue goes through roof assembly rated for type of construction - no shaft required however need plans to show chase support using unistruts from beams/also need structural letter for roof deck cutout-also need UL listing for mono coat repair for areas where removed - no firestopping is required (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 964488 |
Waste Water Div | Splice 5/23/17 | N | 5/26/2017 | CSUREVIEW | CSUREVIEW | No new wastewater service line proposed outside the building. Verified that existing grease interceptor of 4,000 gal. capacity is OK. HSF | hfranson | Waste Water Div | 963878 |
Electrical | Splice 5/23/17 | A | 5/26/2017 | BERTHA | BERTHA | | | Electrical | 963871 |
Out to Review | Splice 5/23/17 | / | 5/26/2017 | RITA | RITA | walking through electrical, then checking it out. | | Out to Review | 963859 |
Electrical | Splice 5/23/17 | / | 5/26/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 963817 |
Plan Coordinator | Splice 5/23/17 | / | 5/26/2017 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 963781 |
Plumbing | Splice 5/23/17 | D | 5/26/2017 | DALEH | DALEH | need to send back to waste water due to G.W. sizing chart change all else ok no circ. pump required per Joel S. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 963780 |
Mechanical | Splice 5/23/17 | A | 5/26/2017 | DALEH | DALEH | all pages replaced with new design professional Engineers stamp, previous Engineers design is voided | | Mechanical | 963773 |
Mechanical | Splice 5/23/17 | / | 5/26/2017 | | DANM | Location = Mechanical by DANM | | Mechanical | 963764 |
Construction | Splice 5/23/17 | D | 5/26/2017 | DANM | DANM | Shaft Detail - revise detail to remove shaft and instead show through penetration / fire stop requirements at ceiling per duct manufacturer's requirements
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 963763 |
Construction | Splice 5/23/17 | / | 5/24/2017 | DANM | DANM | In Current Review by DANM | | Construction | 962864 |
Construction | Splice 5/23/17 | / | 5/23/2017 | | SCANNING | Location = Construction by SCANNING | | Construction | 962662 |
Plan Coordinator | Splice 5/23/17 | / | 5/23/2017 | | BECKYA | Location = Plan Coordinator by BECKYA | | Plan Coordinator | 962658 |
Out to Review | Splice 5/23/17 | / | 5/23/2017 | BECKYA | BECKYA | | | Out to Review | 962638 |
Out to Review | 11/4/16 | / | 11/18/2016 | NELIDA | NELIDA | Mike 719-251-3235 | | Out to Review | 918795 |
Scanned/Finished Bin | 11/4/16 | / | 11/15/2016 | | JESSICAM | Location = Scanned/Finished Bin by JESSICAM | | Scanned/Finished Bin | 917764 |
To Be Scanned Bin | 11/4/16 | / | 11/15/2016 | | JESSICAM | Location = To Be Scanned Bin by JESSICAM | | To Be Scanned Bin | 917726 |
Plan Coordinator | 11/4/16 | / | 11/15/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 917676 |
Mechanical | 11/4/16 | A | 11/15/2016 | JUSTINC | JUSTINC | This splice is approved. In review noticed comments from mech. inspector that have not been addressed. I will list below.
CONSULTED WITH PROPOSED MECHANICAL CONTRACTOR AND BUILDING INSPECTOR. PENETRATION IN RATED ROOF CEILING ASSEMBLY WITH SOLID FUEL VENT ASSEMBLY WILL HAVE TO BE ADDRESSED BY ARCHITECT FOR PROTECTION AND HAVE PLANS REVISED FOR THAT DETAIL. ANY CHANGES TO VENT MATERIALS OTHER THEN WHAT IS STATED ON APPROVED PLANS WILL REQUIRE A SPLICE FOR CHANGES. DELETION OF FIRE DAMPERS AND/OR ANY NEW WALLS THAT MAY REQUIRE FIRE DAMPERS WILL ALSO REQUIRE PLAN REVISIONS. | | Mechanical | 917674 |
Mechanical | 11/4/16 | / | 11/15/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 917671 |
Mechanical | 11/4/16 | / | 11/15/2016 | | JUSTINC | Location = Mechanical by JUSTINC | | Mechanical | 917670 |
Out to Review | 11/4/16 | / | 11/4/2016 | GITA | GITA | | | Out to Review | 915764 |
Hazmat | Original | N | 7/22/2016 | CSFIRE | CSFIRE | | rpeterson | Hazmat | 889482 |
CO Springs Fire | Original | A | 7/22/2016 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland T (see full review) | csfdit | CO Springs Fire | 889478 |
Waste Water Div | Original | A | 7/19/2016 | CSUREVIEW | CSUREVIEW | All wastewater is interior plumbing work. Existing grease interceptor is sized appropriately. Plan set returned to customer. TJV 7/19/16 | tvazansky | Waste Water Div | 888478 |
Mechanical | Original | A | 7/19/2016 | DALEH | DALEH | | | Mechanical | 888414 |
Out to Review | Original | / | 7/18/2016 | REBECCA | REBECCA | coy 719-217-8967 | | Out to Review | 888002 |
Finished Bin | Original | / | 7/13/2016 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 887029 |
Plan Coordinator | Original | / | 7/13/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 886998 |
Plumbing | Original | A | 7/13/2016 | TCRIPPEN | TCRIPPEN | | | Plumbing | 886995 |
Plumbing | Original | / | 7/12/2016 | | KENYATTA | Location = Plumbing by KENYATTA | | Plumbing | 886614 |
Plan Coordinator | Original | / | 7/12/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 886605 |
Mechanical | Original | D | 7/12/2016 | JUSTINC | JUSTINC | Provide drawing showing proposed vent routing. Provide vent penetration detail Verify if fan will be used with pizza oven venting? If so schedule Verify comb. air requirements
RETURN RED AND GREEN COMMENT SHEETS WITH NEXT REVIEW NO WALK | | Mechanical | 886603 |
Mechanical | Original | / | 7/12/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 886453 |
Mechanical | Original | / | 7/11/2016 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 886308 |
Waste Water Div | Original | D | 7/1/2016 | CSUREVIEW | CSUREVIEW | Please provide size and location of existing grease interceptor, label grease waste line and ensure fixtures are connected to appropriate grease line. CQ | cquinn_ds | Waste Water Div | 884319 |
Water Division | Original | A | 7/1/2016 | CSUREVIEW | CSUREVIEW | No new service lines proposed CQ | cquinn_ds | Water Division | 884315 |
CSU Utilities | Original | / | 6/30/2016 | | CSFIRE | Location = CSU Utilities by CSFIRE | dwithee | CSU Utilities | 884154 |
Hazmat | Original | D | 6/30/2016 | CSFIRE | CSFIRE | | dwithee | Hazmat | 884150 |
CO Springs Fire | Original | D | 6/30/2016 | CSFIRE | CSFIRE | (see full review) | csfdit | CO Springs Fire | 884149 |
Health Dept. | Original | A | 6/30/2016 | HEALTHDEPT | HEALTHDEPT | Approved in plan review. A pre-operational inspection will be required before final approval for opening is granted. Debbie 578-3136 | Debbie Polelli | Health Dept. | 884046 |
Fire | Original | / | 6/29/2016 | | MBINGMAN | Location = Fire by MBINGMAN | | Fire | 883739 |
CO Springs DRE | Original | N | 6/29/2016 | MBINGMAN | MBINGMAN | Interior Remodel Only. No change of use. (see full review) | | CO Springs DRE | 883738 |
Zoning/Planning | Original | / | 6/24/2016 | | RITA | Location = Zoning/Planning by RITA | | Zoning/Planning | 882561 |
Plan Coordinator | Original | / | 6/24/2016 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 882557 |
Electrical | Original | A | 6/24/2016 | SHELBY | SHELBY | | | Electrical | 882556 |
Electrical | Original | / | 6/24/2016 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 882554 |
Electrical | Original | / | 6/16/2016 | | RITA | Location = Electrical by RITA | | Electrical | 880474 |
Plan Coordinator | Original | / | 6/16/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 880423 |
Plumbing | Original | D | 6/16/2016 | TCRIPPEN | TCRIPPEN | vegetable sink to be indirect waste, all hand sinks to be 110 degrees max with mixing valve, hot water source to be within 50' without pump.schedule all materials used.provide water pipe size analysis data on plans,missing engineer stamp ,verify sinks are going to the grease interceptor. | | Plumbing | 880422 |
Plumbing | Original | / | 6/16/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Plumbing | 880346 |
Plumbing | Original | / | 6/13/2016 | | KENYATTA | Location = Plumbing by KENYATTA | | Plumbing | 879452 |
Plan Coordinator | Original | / | 6/13/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 879430 |
Mechanical | Original | D | 6/13/2016 | JUSTINC | JUSTINC | Missing P.E stamp on sheets? Too many things to list see plans for comments
REVIEW INCOMPLETE NO WALK | | Mechanical | 879429 |
Mechanical | Original | / | 6/13/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 879279 |
Mechanical | Original | / | 6/13/2016 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 879278 |
Electrical | Original | / | 6/9/2016 | | RITA | Location = Electrical by RITA | | Electrical | 878585 |
Plan Coordinator | Original | / | 6/9/2016 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 878570 |
Construction | Original | A | 6/9/2016 | JIMA | JIMA | | | Construction | 878569 |
Construction | Original | / | 6/8/2016 | JIMA | JIMA | In Current Review by JIMA | | Construction | 878445 |
Construction | Original | / | 6/8/2016 | | RITA | Location = Construction by RITA | | Construction | 878339 |
Enumeration | Original | A | 6/6/2016 | AMY | AMY | Part of the hotel. | | Enumeration | 877460 |
Out to Review | Original | / | 6/6/2016 | BPHILLIPS | BPHILLIPS | Jack walking to enumerations | | Out to Review | 877447 |
Floodplain | Original | N | 6/6/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 877446 |