Construction | 1/20/17 | A | 1/24/2017 | MICHAELA | MICHAELA | Add ceiling | | Construction | 932084 |
Out to Review | 1/20/17 | / | 1/20/2017 | GITA | GITA | | | Out to Review | 931413 |
Construction | 1/9/16 | A | 1/9/2017 | MICHAELA | MICHAELA | Soffit detail - not rated | | Construction | 928973 |
Out to Review | Original | / | 10/20/2016 | REBECCA | REBECCA | chris 492-5076 | | Out to Review | 912342 |
Scanned/Finished Bin | Original | / | 10/19/2016 | | RITA | Location = Scanned/Finished Bin by RITA | | Scanned/Finished Bin | 911828 |
To Be Scanned Bin | Original | / | 10/19/2016 | | RITA | Location = To Be Scanned Bin by RITA | | To Be Scanned Bin | 911822 |
Plan Coordinator | Original | / | 10/19/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 911754 |
Mechanical | Original | A | 10/19/2016 | JUSTINC | JUSTINC | | | Mechanical | 911753 |
Mechanical | Original | / | 10/19/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 911744 |
Mechanical | Original | / | 10/18/2016 | NELIDA | NELIDA | New sheet (M1,1) was added after 9/21 approval. Review required. | | Mechanical | 911607 |
Scanned/Finished Bin | Original | / | 10/18/2016 | | JESSICAM | Location = Scanned/Finished Bin by JESSICAM | | Scanned/Finished Bin | 911579 |
To Be Scanned Bin | Original | / | 10/17/2016 | | MINDY | Location = To Be Scanned Bin by MINDY | | To Be Scanned Bin | 911158 |
Electrical | Original | A | 10/17/2016 | BERTHA | BERTHA | Re-approved for addition of ice maker. | | Electrical | 911156 |
Plumbing | Original | A | 10/17/2016 | TCRIPPEN | TCRIPPEN | new pages added ice maker line | | Plumbing | 911118 |
Health Dept. | Original | A | 10/13/2016 | HEALTHDEPT | HEALTHDEPT | Approved in plan review. A pre-operational inspection will be required before final approval for opening is granted. Ankit Parikh 578-3278 | Aparikh | Health Dept. | 910545 |
Plumbing | Original | A | 10/5/2016 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 908271 |
Construction | Original | A | 10/5/2016 | SHELLEY | SHELLEY | revised floor plan | | Construction | 908261 |
Electrical | Original | A | 9/22/2016 | BERTHA | BERTHA | | | Electrical | 905335 |
Plumbing | Original | D | 9/22/2016 | TCRIPPEN | TCRIPPEN | The sinks for the women`s restroom are not in with the toilet they are in the hall way rest rooms to be labeled men`s and women`s, see section 405.3.2 of the 2012 IPC. | | Plumbing | 905322 |
Mechanical | Original | A | 9/21/2016 | JUSTINC | JUSTINC | | | Mechanical | 905108 |
Plumbing | Original | D | 9/21/2016 | TCRIPPEN | TCRIPPEN | no to the floor sink for ped chairs | | Plumbing | 905078 |
Out to Review | Original | / | 9/14/2016 | BPHILLIPS | BPHILLIPS | Courtney 815 761 8685 | | Out to Review | 903093 |
Finished Bin | Original | / | 9/12/2016 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 902696 |
Health Dept. | Original | D | 9/12/2016 | HEALTHDEPT | HEALTHDEPT | Plan review required. Please contact the health department at (719) 578-3199 option 3. AParikh (719) 578-3278 | Aparikh | Health Dept. | 902682 |
Health Dept. | Original | / | 9/8/2016 | | REBECCA | Location = Health Dept. by REBECCA | | Health Dept. | 901944 |
Hazmat | Original | N | 9/6/2016 | CSFIRE | CSFIRE | | wtaylor | Hazmat | 901286 |
CO Springs Fire | Original | A | 9/6/2016 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 901285 |
Fire | Original | / | 9/2/2016 | | MBINGMAN | Location = Fire by MBINGMAN | | Fire | 900909 |
CO Springs DRE | Original | A | 9/2/2016 | MBINGMAN | MBINGMAN | Occupant to be a Salon. Use permitted in PBC. Exterior needs to match DP. No signage approved as part of this review. (see full review) | | CO Springs DRE | 900908 |
Zoning/Planning | Original | / | 9/1/2016 | | CSUAPPSPRM | Location = Zoning/Planning by CSUAPPSPRM | mkluke | Zoning/Planning | 900653 |
CSU Contract Admin. | Original | N | 9/1/2016 | CSUAPPSPRM | CSUAPPSPRM | Water and wastewater service from master meter at 5925 Dublin Blvd - commercial water meter sizing form approved for entire bldg. - MKL | mkluke | CSU Contract Admin. | 900652 |
CSU Contract Admin. | Original | / | 9/1/2016 | | RITA | Location = CSU Contract Admin. by RITA | | CSU Contract Admin. | 900382 |
Plan Coordinator | Original | / | 8/31/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 900368 |
Plumbing | Original | D | 8/31/2016 | TCRIPPEN | TCRIPPEN | pedicure chairs to be indirect waste provide manufacture install book, men's to be separate from women`s the sink is to be in with the toilet, water and waste water removed not required. | | Plumbing | 900367 |
Plumbing | Original | / | 8/29/2016 | | KENYATTA | Location = Plumbing by KENYATTA | | Plumbing | 899289 |
Plan Coordinator | Original | / | 8/29/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 899179 |
Mechanical | Original | D | 8/29/2016 | JUSTINC | JUSTINC | Provide air balance schedule Indicate % of O.S.A in RTU schedule Provide typ. detail for exhaust installation in manicure bar and pedicure stations Gas checked ok
SEE PLANS FOR ALL ADDITIONAL COMMENTS RETURN RED LINE COMMENT SHEETS WITH NEXT REVIEW WALK OK | | Mechanical | 899178 |
Mechanical | Original | / | 8/29/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 899104 |
Mechanical | Original | / | 8/26/2016 | | BPHILLIPS | Location = Mechanical by BPHILLIPS | | Mechanical | 898655 |
Electrical | Original | D | 8/26/2016 | BERTHA | BERTHA | 1. Depict and label all meters per enumerated address on one-line. 2. Label floor plan to match enumerated addresses. | | Electrical | 898639 |
Construction | Original | A | 8/26/2016 | MICHAELA | MICHAELA | | | Construction | 898607 |
Enumeration | Original | A | 8/26/2016 | AMY | AMY | see floor plan page A1.0 | | Enumeration | 898590 |
Out to Review | Original | / | 8/26/2016 | REBECCA | REBECCA | walking | | Out to Review | 898580 |
Floodplain | Original | N | 8/26/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 898579 |
Floodplain | Original | N | 8/26/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 898578 |