- Not Set - | Splice 12/4/17 | / | 1/20/2021 | | BECKYA | Location = - Not Set - by BECKYA | | - Not Set - | 1442963 |
Out to Review | Splice 8/21/18 | / | 8/23/2018 | NELIDA | NELIDA | Charlie picked up | | Out to Review | 1103237 |
Scanned/Finished Bin | Splice 8/21/18 | / | 8/22/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1102447 |
To Be Scanned Bin | Splice 8/21/18 | / | 8/22/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1102397 |
Plan Coordinator | Splice 8/21/18 | / | 8/22/2018 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 1102382 |
Construction | Splice 8/21/18 | A | 8/22/2018 | DANM | DANM | Penthouse framing for elevator stairs and new canopy framing at entry | | Construction | 1102380 |
Construction | Splice 8/21/18 | / | 8/21/2018 | DANM | DANM | In Current Review by DANM | | Construction | 1102347 |
Construction | Splice 8/21/18 | / | 8/21/2018 | | BECKYA | Location = Construction by BECKYA | | Construction | 1102272 |
Out to Review | Splice 8/21/18 | / | 8/21/2018 | BECKYA | BECKYA | | | Out to Review | 1102129 |
Scanned/Finished Bin | Splice 07/09/18 | / | 7/12/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1088845 |
To Be Scanned Bin | Splice 07/09/18 | / | 7/12/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1088630 |
Plan Coordinator | Splice 07/09/18 | / | 7/11/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1088625 |
Electrical | Splice 07/09/18 | A | 7/11/2018 | SHELBY | SHELBY | | | Electrical | 1088624 |
Electrical | Splice 07/09/18 | / | 7/9/2018 | | RITA | Location = Electrical by RITA | | Electrical | 1087497 |
Construction | 4/3/2018 | A | 4/5/2018 | MICHAELA | MICHAELA | Revise elevator walls to 1-hr - remove rating from stairs | | Construction | 1054406 |
Out to Review | 4/3/2018 | / | 4/3/2018 | JANE | JANE | walking | | Out to Review | 1053334 |
Plumbing | Splice 12/07/17 | A | 12/7/2017 | TCRIPPEN | TCRIPPEN | okay,updated fixture and water pipe calculations , changed irrigation pipe size to 2 inch changed back flow perventer all so look at the clouds for changes plus see narrative letter | | Plumbing | 1019508 |
Plan Coordinator | Splice 12/4/17 | / | 12/5/2017 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1017658 |
Construction | Splice 12/4/17 | A | 12/5/2017 | MICHAELA | MICHAELA | Clarify ceiling details | | Construction | 1017656 |
Construction | Splice 12/4/17 | / | 12/4/2017 | | BECKYA | Location = Construction by BECKYA | | Construction | 1017438 |
Out to Review | Splice 9/21/2017 | / | 10/27/2017 | NELIDA | NELIDA | Steven Mazzoni 913-645-3556 | | Out to Review | 1007613 |
Scanned/Finished Bin | Splice 9/21/2017 | / | 10/18/2017 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1005426 |
To Be Scanned Bin | Splice 9/21/2017 | / | 10/18/2017 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1005205 |
Mechanical | Splice 9/21/2017 | A | 10/18/2017 | JUSTINC | JUSTINC | Approved for the latest deltas on each sheet | | Mechanical | 1005188 |
Out to Review | Splice 9/21/2017 | / | 10/13/2017 | NELIDA | NELIDA | Gina 719-884-4454 | | Out to Review | 1003990 |
Finished Bin | Splice 9/21/2017 | / | 10/13/2017 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1003817 |
Plan Coordinator | Splice 9/21/2017 | / | 10/13/2017 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1003805 |
Mechanical | Splice 9/21/2017 | D | 10/13/2017 | DALEH | DALEH | see green line comments on sheets M101A and M502 (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1003804 |
Mechanical | Splice 9/21/2017 | / | 10/12/2017 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1003730 |
Resubmittal 1 | Splice 9/21/2017 | / | 10/12/2017 | GITA | GITA | Resubmittal #1 | | Resubmittal 1 | 1003676 |
Mechanical | Splice 9/21/2017 | / | 10/12/2017 | | GITA | Location = Mechanical by GITA | | Mechanical | 1003675 |
Finished Bin | Splice 9/21/2017 | / | 10/12/2017 | | SCANNING | Location = Finished Bin by SCANNING oversized bin | | Finished Bin | 1003404 |
CO Springs Fire | Splice 9/21/2017 | A | 10/11/2017 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 1002966 |
Fire | Splice 9/21/2017 | / | 10/4/2017 | | SCANNING | Location = Fire by SCANNING | | Fire | 1001141 |
Plan Coordinator | Splice 9/21/2017 | / | 10/4/2017 | | SCANNING | Location = Plan Coordinator by SCANNING | | Plan Coordinator | 1001140 |
Out to Review | Splice 9/21/2017 | / | 10/4/2017 | BECKYA | BECKYA | picked up by Larry | | Out to Review | 1001061 |
Plan Coordinator | Splice 9/21/2017 | / | 10/4/2017 | | ERIC | Location = Plan Coordinator by ERIC | | Plan Coordinator | 1001040 |
Elevators | Splice 9/21/2017 | A | 10/4/2017 | ERIC | ERIC | TKE Endura | | Elevators | 1001039 |
Elevators | Splice 9/21/2017 | / | 10/3/2017 | | SCANNING | Location = Elevators by SCANNING | | Elevators | 1000941 |
Plumbing | Splice 9/21/2017 | A | 10/3/2017 | TCRIPPEN | TCRIPPEN | P001, added material schedule clouded note 27 - 28 for easy read,P100A room A1.11 relocated OSD relocated 2" vent up,relocated 6" st up,P101A added co and relocated 6 ' st DN,P101B relocated 22' vent, 6" st up and DN to 12" above grade level, P102B relocate 6" st to other side,P301 added 2 ' WCO,P302 added valves to equipment,P402 change 6 'DSN to 8 ' UST, P403 relocate 4 ' OSD piping, P404 added sizes to HWRCP-ADM-1-1, P501 added detail for eye wall, 502 redesign water diagram.601 added ANSI note to schedule, P603 changed pump size . | | Plumbing | 1000935 |
Plumbing | Splice 9/21/2017 | / | 10/3/2017 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1000695 |
Plan Coordinator | Splice 9/21/2017 | / | 10/3/2017 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1000646 |
Mechanical | Splice 9/21/2017 | D | 10/3/2017 | DALEH | DALEH | need to delta and number each delta at each clouded change no review no walk (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1000644 |
Mechanical | Splice 9/21/2017 | / | 9/28/2017 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 999396 |
Mechanical | Splice 9/21/2017 | / | 9/27/2017 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 999041 |
Plan Coordinator | Splice 9/21/2017 | / | 9/27/2017 | | BERTHA | Location = Plan Coordinator by BERTHA | | Plan Coordinator | 999035 |
Electrical | Splice 9/21/2017 | A | 9/27/2017 | BERTHA | BERTHA | Added load bank, cable tray and associated feeders. Removed U.G. feeder to/from UPS. Various lighting and power revisions. Revised one-lines. Revised schedules. | | Electrical | 999034 |
Electrical | Splice 9/21/2017 | / | 9/22/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 998033 |
Plan Coordinator | Splice 9/21/2017 | / | 9/22/2017 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 998002 |
Construction | Splice 9/21/2017 | A | 9/22/2017 | MICHAELA | MICHAELA | Revised details - some added rated walls | | Construction | 998000 |
Construction | Splice 9/21/2017 | / | 9/21/2017 | | MINDY | Location = Construction by MINDY | | Construction | 997510 |
Scanned/Finished Bin | Splice 8/11/2017 | / | 8/11/2017 | | JESSICAM | Location = Scanned/Finished Bin by JESSICAM | | Scanned/Finished Bin | 986175 |
To Be Scanned Bin | Splice 8/11/2017 | / | 8/11/2017 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 986134 |
Construction | Splice 8/11/2017 | A | 8/11/2017 | MICHAELA | MICHAELA | | | Construction | 986099 |
Construction | Splice 7/28/17 | A | 8/7/2017 | DANM | DANM | Listed assembly for duct - 24" o.c. framing; listed assembly for beam rating at exterior wall - other than IBC | | Construction | 984385 |
Mechanical | Splice 7/28/17 | A | 8/7/2017 | DALEH | DALEH | splice add damper framing detail | | Mechanical | 984352 |
Resubmittal 3 | Splice 7/28/17 | / | 8/7/2017 | BECKYA | BECKYA | Resubmittal #3 | | Resubmittal 3 | 984336 |
Out to Review | Splice 7/28/17 | / | 7/31/2017 | RITA | RITA | Gina 719-884-4454 | | Out to Review | 982623 |
Finished Bin | Splice 7/28/17 | / | 7/31/2017 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 982570 |
Construction | Splice 7/28/17 | D | 7/31/2017 | SCANNING | SCANNING | Pages not stamped Incorrect height on 18" vertical grab bar Clarify changes on A500 or remove page (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 982530 |
Resubmittal 2 | Splice 7/28/17 | / | 7/31/2017 | SCANNING | SCANNING | Resubmittal #2 | | Resubmittal 2 | 982526 |
Finished Bin | Splice 7/28/17 | / | 7/31/2017 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 982416 |
Electrical | Splice 7/28/17 | / | 7/31/2017 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electrical | 982322 |
Resubmittal 1 | Splice 7/28/17 | / | 7/28/2017 | RITA | RITA | Resubmittal #1 | | Resubmittal 1 | 982217 |
Electrical | Splice 7/28/17 | / | 7/28/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 982095 |
Plan Coordinator | Splice 7/28/17 | / | 7/28/2017 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 982051 |
Construction | Splice 7/28/17 | D | 7/28/2017 | DANM | DANM | No Review Splice should consistent of only latest copy of every sheet that is included (there should not be multiple copies of any sheet) All sheets should be stamped and dated by design professional of record for that discipline Returned to Finished Bin (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 982050 |
Construction | Splice 7/28/17 | / | 7/28/2017 | | SCANNING | Location = Construction by SCANNING | | Construction | 982003 |
Plan Coordinator | Splice 7/28/17 | / | 7/28/2017 | | BECKYA | Location = Plan Coordinator by BECKYA | | Plan Coordinator | 981957 |
Out to Review | Original | / | 3/3/2017 | RITA | RITA | GINA | | Out to Review | 940914 |
Scanned/Finished Bin | Original | / | 3/2/2017 | | JLANE | Location = Scanned/Finished Bin by JLANE. ON DOLLY | | Scanned/Finished Bin | 940616 |
Mechanical | Original | A | 3/2/2017 | DALEH | DALEH | re-approved sheets M-101B and M604 | | Mechanical | 940563 |
To Be Scanned Bin | Original | / | 2/27/2017 | | MINDY | Location = To Be Scanned Bin by MINDY | | To Be Scanned Bin | 939637 |
Hazmat | Original | A | 2/23/2017 | CSFIRE | CSFIRE | Plans acceptable. 3rd review fee charged. Plans forwarded to RBD. (see full review) | smitty91 | Hazmat | 938796 |
Hazmat | Original | / | 2/17/2017 | | MINDY | Location = Hazmat by MINDY | | Hazmat | 937660 |
Resubmittal 6 | Original | / | 2/17/2017 | MINDY | MINDY | Resubmittal #6 | | Resubmittal 6 | 937659 |
Out to Review | Original | / | 2/15/2017 | JANE | JANE | ALexandra 303 601 2473 | | Out to Review | 937083 |
Finished Bin | Original | / | 2/15/2017 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 937017 |
Hazmat | Original | D | 2/14/2017 | CSFIRE | CSFIRE | Disapproved. Read attached comments, address and resubmit. Additional review fees apply hereafter. Forwarded to RBD. (see full review) | smitty91 | Hazmat | 936900 |
CO Springs Fire | Original | A | 2/10/2017 | CSFIRE | CSFIRE | | dwithee | CO Springs Fire | 936261 |
Fire | Original | / | 2/10/2017 | | HVANNIMWEGEN | Location = Fire by HVANNIMWEGEN | | Fire | 936039 |
CO Springs DRE | Original | A | 2/10/2017 | HVANNIMWEGEN | HVANNIMWEGEN | Approved. (see full review) | | CO Springs DRE | 936038 |
Zoning/Planning | Original | / | 2/8/2017 | | JLANE | Location = Zoning/Planning by JLANE | | Zoning/Planning | 935601 |
Electrical | Original | A | 2/8/2017 | SHELBY | SHELBY | | | Electrical | 935487 |
Plan Coordinator | Original | / | 2/8/2017 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 935486 |
Electrical | Original | / | 2/7/2017 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 935037 |
Electrical | Original | / | 2/6/2017 | | RITA | Location = Electrical by RITA | | Electrical | 934661 |
Resubmittal 5 | Original | / | 2/6/2017 | RITA | RITA | Resubmittal #5 | | Resubmittal 5 | 934660 |
Out to Review | Original | / | 1/30/2017 | MINDY | MINDY | Steve 913 645 3556 | | Out to Review | 933123 |
Finished Bin | Original | / | 1/27/2017 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 933081 |
Health Dept. | Original | N | 1/27/2017 | HEALTHDEPT | HEALTHDEPT | Construction activity permit was approved (PT0039057 and is valid to 10/24/2016 to 4/24/2016). AnkitP 719-578-3278 | Aparikh | Health Dept. | 932963 |
Health Dept. | Original | / | 1/23/2017 | | MINDY | Location = Health Dept. by MINDY | | Health Dept. | 931730 |
Gas/Elec. Utils | Original | A | 1/23/2017 | CSUREVIEW | CSUREVIEW | Comments addressed.WTD | wtdavis | Gas/Elec. Utils | 931712 |
Water Division | Original | A | 1/23/2017 | CSUREVIEW | CSUREVIEW | Comments addressed.WTD | wtdavis | Water Division | 931703 |
Waste Water Div | Original | A | 1/23/2017 | CSUREVIEW | CSUREVIEW | Comments addressed.WTD | wtdavis | Waste Water Div | 931701 |
Electrical | Original | D | 1/10/2017 | BPHILLIPS | BPHILLIPS | changed back after issuing attachment (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 929202 |
Electrical | Original | A | 1/10/2017 | BPHILLIPS | BPHILLIPS | to enable underground | | Electrical | 929196 |
CSU Utilities | Original | / | 1/9/2017 | | MINDY | Location = CSU Utilities by MINDY | | CSU Utilities | 928896 |
CSU Contract Admin. | Original | A | 1/6/2017 | CSUAPPSPRM | CSUAPPSPRM | Development charges/fees paid. LMP | lmpope | CSU Contract Admin. | 928512 |
City Engr | Original | A | 12/28/2016 | CSENGINEER | CSENGINEER | Plan routed to CSU Utilities. pvm | csengineer | City Engr | 927029 |
Hazmat | Original | D | 12/27/2016 | CSFIRE | CSFIRE | Read and address disapproved comments. Forwarded to CSU. (see full review) | smitty91 | Hazmat | 926551 |
Fire | Original | / | 12/23/2016 | | MINDY | Location = Fire by MINDY | | Fire | 926317 |
CO Springs Fire | Original | D | 12/23/2016 | CSFIRE | CSFIRE | outstanding items include: 2-way elevator communications per 1007.9 and hazmat inventory. Plan Location - HazMat (see full review) | csfdit | CO Springs Fire | 926254 |
CO Springs DRE | Original | D | 12/21/2016 | RDCUSER | RDCUSER | Include approved development plan and approved / recorded Final Plat (see full review) | | CO Springs DRE | 925882 |
CSU Contract Admin. | Original | D | 12/21/2016 | CSUAPPSPRM | CSUAPPSPRM | Plan taken to DRE. | lmpope | CSU Contract Admin. | 925649 |
CSU Contract Admin. | Original | D | 12/21/2016 | CSUAPPSPRM | CSUAPPSPRM | Requires payment of development charges/fees. LMP | lmpope | CSU Contract Admin. | 925646 |
CSU Contract Admin. | Original | / | 12/20/2016 | | JESSICAM | Location = CSU Contract Admin. by JESSICAM | | CSU Contract Admin. | 925380 |
Plan Coordinator | Original | / | 12/20/2016 | | ERIC | Location = Plan Coordinator by ERIC | | Plan Coordinator | 925169 |
Elevators | Original | A | 12/20/2016 | ERIC | ERIC | Thyssenkrupp 2 stop Endura. elevator must be registered with the State prior to final | | Elevators | 925166 |
Elevators | Original | / | 12/19/2016 | | JESSICAM | Location = Elevators by JESSICAM | | Elevators | 925112 |
Plan Coordinator | Original | / | 12/19/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 925092 |
Plumbing | Original | A | 12/19/2016 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 925090 |
Plumbing | Original | / | 12/19/2016 | | TCRIPPEN | Location = Plumbing by TCRIPPEN | | Plumbing | 925070 |
Mechanical | Original | / | 12/19/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Mechanical | 925069 |
Mechanical | Original | A | 12/19/2016 | DALEH | DALEH | | | Mechanical | 925068 |
Mechanical | Original | / | 12/12/2016 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 923442 |
Mechanical | Original | / | 12/8/2016 | | RITA | Location = Mechanical by RITA | | Mechanical | 922970 |
Plan Coordinator | Original | / | 12/8/2016 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 922967 |
Electrical | Original | D | 12/8/2016 | SHELBY | SHELBY | 1. Please comply with previous review comment 1 (3000-3UG etc.). 2. Comply 240.21(C) NEC for for transformer secondary taps ( 400-4G etc.). 3. When used as a supply side bonding jumper "grounds" must be sized per 250.102(C) NEC ( 250-4G, revised 400-4G see comment #2). 4. Show GEC size for transformers on one line. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 922966 |
Electrical | Original | / | 12/7/2016 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 922621 |
Electrical | Original | / | 12/6/2016 | | JESSICAM | Location = Electrical by JESSICAM | | Electrical | 922260 |
Plan Coordinator | Original | / | 12/6/2016 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 922148 |
Construction | Original | A | 12/6/2016 | DANM | DANM | | | Construction | 922147 |
Construction | Original | / | 12/5/2016 | DANM | DANM | In Current Review by DANM | | Construction | 921959 |
Construction | Original | / | 12/5/2016 | | REBECCA | Location = Construction by REBECCA | | Construction | 921841 |
Plan Coordinator | Original | / | 12/2/2016 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 921828 |
Enumeration | Original | A | 12/2/2016 | AMY | AMY | SEE PAGE C200 FOR SITE PLAN WITH ALL ADDRESSING-SECURITY FENCE 3211, SCREEN WALL FRO TRASH ENCLOSURE 3217 AND MAIN BUILDING 3233 JANITELL ROAD. SEE FRONT LABEL FOR ALL ADDRESSING FRO THIS PLAN AS WELL. 1 PLAN 3 PERMITS REQUIRED. CODE STUDY FORM EDITED BY ENUMERATIONS TO SHOW NEW TAX SCHEDULE & LEGAL DESCRIPTION. SCREEN WALL & SECURITY FENCE ADDED TO DESCRIPTION OF WORK ON CODY STUDY FORM AS WELL. | | Enumeration | 921827 |
Enumeration | Original | / | 12/2/2016 | AMY | AMY | In Current Review by AMY | | Enumeration | 921810 |
Enumeration | Original | / | 12/2/2016 | | REBECCA | Location = Enumeration by REBECCA | | Enumeration | 921809 |
Resubmittal 4 | Original | / | 12/2/2016 | REBECCA | REBECCA | Resubmittal #4 | | Resubmittal 4 | 921808 |
Out to Review | Original | / | 11/28/2016 | NELIDA | NELIDA | Gina 719-884-4454 | | Out to Review | 920489 |
Health Dept. | Original | / | 11/23/2016 | | RITA | Location = Health Dept. by RITA | | Health Dept. | 920254 |
City Engr | Original | D | 11/23/2016 | CSENGINEER | CSENGINEER | Include a copy of the approved Development Plan and a copy of the City Engineering approved Grading & Erosion Control Plan in the building permit set. Plan set route to RBD. pvm | csengineer | City Engr | 920233 |
CSU Utilities | Original | / | 11/22/2016 | | MINDY | Location = CSU Utilities by MINDY | | CSU Utilities | 919848 |
Water Division | Original | D | 11/22/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. Water entry detail must comply with CSU standards, please contact Rob Smith at 668-4561 to discuss proper meter detail and backflow requirements. CQ | cquinn_ds | Water Division | 919822 |
Waste Water Div | Original | D | 11/22/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. CQ | cquinn_ds | Waste Water Div | 919821 |
Gas/Elec. Utils | Original | D | 11/22/2016 | CSUREVIEW | CSUREVIEW | Please show the gas and electric meter locations on the elevation plan views to demonstrate compliance with the required clearance of 3ft around the gas regulator. CQ | cquinn_ds | Gas/Elec. Utils | 919820 |
Hazmat | Original | D | 11/18/2016 | CSFIRE | CSFIRE | | dwithee | Hazmat | 919047 |
CO Springs Fire | Original | D | 11/18/2016 | CSFIRE | CSFIRE | (see full review) | csfdit | CO Springs Fire | 919044 |
Fire | Original | / | 11/17/2016 | | GSANDERS | Location = Fire by GSANDERS | | Fire | 918712 |
CO Springs DRE | Original | D | 11/17/2016 | GSANDERS | GSANDERS | No final plat included in final plans. (see full review) | | CO Springs DRE | 918711 |
CSU Contract Admin. | Original | D | 11/15/2016 | CSUAPPSPRM | CSUAPPSPRM | Commercial Water Meter Sizing Form approved. Requires payment of development charges/fees. LMP | lmpope | CSU Contract Admin. | 917834 |
CSU Contract Admin. | Original | / | 11/10/2016 | | RITA | Location = CSU Contract Admin. by RITA | | CSU Contract Admin. | 917119 |
Plan Coordinator | Original | / | 11/10/2016 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 917117 |
Enumeration | Original | D | 11/10/2016 | AMY | AMY | PAGE C800 INDICATES A TRASH ENCLOSURE SCREENING-IS THIS A SCREEN WALL OR FENCING AT 8 FEET? C8001 INDICATES A SECURITY FENCE AT 10 FEET- HIGH LIGHT THIS FENCING ON SITE PLAN. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 917116 |
Enumeration | Original | / | 11/10/2016 | AMY | AMY | In Current Review by AMY | | Enumeration | 917105 |
Enumeration | Original | / | 11/10/2016 | | RITA | Location = Enumeration by RITA | | Enumeration | 917098 |
Plan Coordinator | Original | / | 11/10/2016 | | ERIC | Location = Plan Coordinator by ERIC | | Plan Coordinator | 917094 |
Elevators | Original | D | 11/10/2016 | ERIC | ERIC | PROVIDE ELEVATOR SUBMITTALS (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 917093 |
Elevators | Original | / | 11/9/2016 | | RITA | Location = Elevators by RITA | | Elevators | 916984 |
Plan Coordinator | Original | / | 11/9/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 916972 |
Plumbing | Original | D | 11/9/2016 | TCRIPPEN | TCRIPPEN | pending room enclosure for cooling equipment drainage on outside of building. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 916970 |
Plumbing | Original | / | 11/9/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Plumbing | 916923 |
Plumbing | Original | / | 11/7/2016 | | MINDY | Location = Plumbing by MINDY | | Plumbing | 916353 |
Mechanical | Original | D | 11/7/2016 | DALEH | DALEH | All Mechanical pages need to be stamped signed and dated by design professional for review no review at this time no walk (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 916298 |
Mechanical | Original | / | 11/2/2016 | | RITA | Location = Mechanical by RITA | | Mechanical | 914850 |
Plan Coordinator | Original | / | 11/1/2016 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 914838 |
Electrical | Original | D | 11/1/2016 | SHELBY | SHELBY | 1. Comply 250.122 (B) NEC for feeder schedule. 2. Comply 110.26 (C)(3) NEC for door swings in STS/PDU rooms. 3. Show over current devices for all feeders on one line. 4. Include feeder schedule on each one line diagram for the feeders used on the diagram. 5. Show SCA for all panels and switch boards on "short circuit duties" table ( RPMU1-3, ELP2 etc.). 6. Remove parallel neutral ( ground) between utility transformers and service disconnects. 7. Show AIC ratings for all panels and switch boards on schedules ( UPSR1OS1, MSB2 etc.). (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 914837 |
Electrical | Original | / | 11/1/2016 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 914524 |
Electrical | Original | / | 10/28/2016 | | DANM | Location = Electrical by DANM | | Electrical | 913876 |
Construction | Original | D | 10/28/2016 | DANM | DANM | Occupant load listed on Code Study Form does not match calculations on drawings Provide sprinkler increase calculations on drawings to show that building is compliant Some values on Energy Code Compliance chart do not match COMcheck submitted with "Foundation Only" permit Guard house will require separate submittal and separate permit Clarify if a majority of the fire ratings shown on the Occupancy & Egress Plan are code requirements - if not, note as such Several doors on door schedule missing required fire rating No walk-through review allowed (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 913860 |
Construction | Original | / | 10/26/2016 | | MINDY | Location = Construction by MINDY | | Construction | 913352 |
Resubmittal 3 | Original | / | 10/26/2016 | MINDY | MINDY | Resubmittal #3 UPGRADE TO FINISH | | Resubmittal 3 | 913349 |
To Be Scanned Bin | Original | / | 10/25/2016 | | MINDY | Location = To Be Scanned Bin by MINDY | | To Be Scanned Bin | 913168 |
Health Dept. | Original | N | 10/25/2016 | HEALTHDEPT | HEALTHDEPT | Construction activity permit was approved (PT0039057 and is valid to 10/24/2016 to 4/24/2016). RN 575-8965 | rnielsen | Health Dept. | 912960 |
Out to Review | Original | / | 10/24/2016 | REBECCA | REBECCA | andy 816-918-4961 | | Out to Review | 912855 |
Finished Bin | Original | / | 10/21/2016 | | JESSICAM | Location = Finished Bin by JESSICAM | | Finished Bin | 912609 |
Health Dept. | Original | D | 10/21/2016 | HEALTHDEPT | HEALTHDEPT | Air quality construction activity permit required. Contact 578-3199 option #3 for more information regarding construction activity permits. RN 575-8965 | rnielsen | Health Dept. | 912591 |
Health Dept. | Original | / | 10/20/2016 | | RITA | Location = Health Dept. by RITA | | Health Dept. | 912275 |
CO Springs DRE | Original | A | 10/20/2016 | RDCUSER | RDCUSER | MRB per LJT - Final Plat inserted into Plans - Ok to approve BP. (see full review) | | CO Springs DRE | 912272 |
Zoning/Planning | Original | / | 10/20/2016 | | REBECCA | Location = Zoning/Planning by REBECCA | | Zoning/Planning | 912267 |
Health Dept. | Original | / | 10/20/2016 | | RITA | Location = Health Dept. by RITA | | Health Dept. | 912169 |
CSU Contract Admin. | Original | N | 10/20/2016 | CSUAPPSPRM | CSUAPPSPRM | Development charges/fees will be due prior to permitting the core/shell or thru finish plan set associated with this project. LMP Plan taken to Regional's front counter. | lmpope | CSU Contract Admin. | 912112 |
CSU Contract Admin. | Original | N | 10/20/2016 | CSUAPPSPRM | CSUAPPSPRM | Development charges/fees will be due prior to permitting the core/shell or thru finish plan set associated with this project. LMP | lmpope | CSU Contract Admin. | 912111 |
City Engr | Original | A | 10/19/2016 | CSENGINEER | CSENGINEER | Plan routed to CSU Contract Admin. pvm | csengineer | City Engr | 911868 |
City Engr (SERT) | Original | / | 10/17/2016 | | LTHELEN | Location = City Engr (SERT) by LTHELEN | | City Engr (SERT) | 911199 |
CO Springs DRE | Original | D | 10/17/2016 | LTHELEN | LTHELEN | Include correct elevations. The elevation directions in the large sheet set do not match the elevation directions in the approved development plan. Include a copy of the recorded subdivision plat. (see full review) | | CO Springs DRE | 911198 |
Zoning/Planning | Original | / | 10/13/2016 | | RITA | Location = Zoning/Planning by RITA | | Zoning/Planning | 910669 |
Plan Coordinator | Original | / | 10/13/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 910666 |
Plumbing | Original | A | 10/13/2016 | TCRIPPEN | TCRIPPEN | approve for underground only. | | Plumbing | 910665 |
Plumbing | Original | / | 10/13/2016 | | RITA | Location = Plumbing by RITA | | Plumbing | 910570 |
Plan Coordinator | Original | / | 10/13/2016 | | MINDY | Location = Plan Coordinator by MINDY | | Plan Coordinator | 910547 |
Resubmittal 2 | Original | / | 10/13/2016 | MINDY | MINDY | Resubmittal #2 | | Resubmittal 2 | 910546 |
Water Division | Original | A | 10/11/2016 | CSUREVIEW | CSUREVIEW | Per Bill Davis, UDS APPROVAL TO PROCEED WITH FOUNDATION ONLY, SERVICE CONTRACT HOLD IN PLACE ON THIS PROJECT: PLAN STILL REQUIRES THE FOLLOWING: Approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. CQ | cquinn_ds | Water Division | 909999 |
Waste Water Div | Original | A | 10/11/2016 | CSUREVIEW | CSUREVIEW | Per Bill Davis, UDS APPROVAL TO PROCEED WITH FOUNDATION ONLY, SERVICE CONTRACT HOLD IN PLACE ON THIS PROJECT: PLAN STILL REQUIRES THE FOLLOWING: Approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. CQ | cquinn_ds | Waste Water Div | 909998 |
Out to Review | Original | / | 10/5/2016 | NELIDA | NELIDA | Gina 719-884-4454 | | Out to Review | 908287 |
Finished Bin | Original | / | 10/5/2016 | | RITA | Location = Finished Bin by RITA | | Finished Bin | 908126 |
City Engr | Original | D | 10/4/2016 | CSENGINEER | CSENGINEER | Include a copy of the approved Development Plan and a copy of the City Engineering approved Grading & Erosion Control Plan in the building permit set. Plan set route to RBD. pvm | csengineer | City Engr | 908099 |
Water Division | Original | D | 9/28/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. CQ | cquinn_ds | Water Division | 906711 |
Waste Water Div | Original | D | 9/28/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. CQ | cquinn_ds | Waste Water Div | 906707 |
CSU Utilities | Original | / | 9/28/2016 | | CSFIRE | Location = CSU Utilities by CSFIRE | wtaylor | CSU Utilities | 906604 |
Fire | Original | / | 9/27/2016 | | RDCUSER | Location = Fire by RDCUSER | | Fire | 906567 |
CO Springs DRE | Original | D | 9/27/2016 | RDCUSER | RDCUSER | Provide approved DP and FP. RTL per LJT (see full review) | | CO Springs DRE | 906566 |
Zoning/Planning | Original | / | 9/27/2016 | | MINDY | Location = Zoning/Planning by MINDY | | Zoning/Planning | 906303 |
Plan Coordinator | Original | / | 9/27/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 906300 |
Plumbing | Original | D | 9/27/2016 | TCRIPPEN | TCRIPPEN | See red lines on P 303 heat cable shall not be inside of the waste lines, Missing engineer stamp not on all the pages | | Plumbing | 906296 |
Plumbing | Original | / | 9/26/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Plumbing | 906026 |
Plumbing | Original | / | 9/26/2016 | | MINDY | Location = Plumbing by MINDY | | Plumbing | 905978 |
Plan Coordinator | Original | / | 9/26/2016 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 905975 |
Construction | Original | A | 9/26/2016 | DANM | DANM | | | Construction | 905974 |
Construction | Original | / | 9/26/2016 | DANM | DANM | In Current Review by DANM | | Construction | 905869 |
Construction | Original | / | 9/23/2016 | | REBECCA | Location = Construction by REBECCA | | Construction | 905811 |
Resubmittal 1 | Original | / | 9/23/2016 | REBECCA | REBECCA | Resubmittal #1 | | Resubmittal 1 | 905810 |
Out to Review | Original | / | 9/8/2016 | NELIDA | NELIDA | Gina 884-4454 | | Out to Review | 901837 |
Finished Bin | Original | / | 9/7/2016 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 901620 |
Health Dept. | Original | D | 9/7/2016 | HEALTHDEPT | HEALTHDEPT | Air quality construction activity permit required. Contact 578-3199 option #3 for more information regarding construction activity permits. Plan review may be required. AB 352-1842 | abrannon | Health Dept. | 901616 |
Health Dept. | Original | / | 9/2/2016 | | KENYATTA | Location = Health Dept. by KENYATTA | | Health Dept. | 900858 |
Water Division | Original | D | 9/2/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. mjg | mgackle | Water Division | 900760 |
Water Division | Original | D | 9/2/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. CQ | mgackle | Water Division | 900759 |
Waste Water Div | Original | D | 9/2/2016 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved Utility Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8259 with questions. mjg | mgackle | Waste Water Div | 900758 |
Gas/Elec. Utils | Original | N | 9/2/2016 | CSUREVIEW | CSUREVIEW | Foundation Only. mjg | mgackle | Gas/Elec. Utils | 900755 |
City Engr | Original | D | 8/31/2016 | CSENGINEER | CSENGINEER | Include a copy of the approved Development Plan and a copy of the City Engineering approved Grading & Erosion Control Plan in the building permit set. Plan set route to CSU utilities. pvm | csengineer | City Engr | 900303 |
CSU Utilities | Original | / | 8/31/2016 | | CSFIRE | Location = CSU Utilities by CSFIRE | wtaylor | CSU Utilities | 900289 |
Hazmat | Original | N | 8/31/2016 | CSFIRE | CSFIRE | | wtaylor | Hazmat | 900287 |
CO Springs Fire | Original | N | 8/31/2016 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 900285 |
Fire | Original | / | 8/31/2016 | | RLOZANO | Location = Fire by RLOZANO | | Fire | 900087 |
CO Springs DRE | Original | D | 8/31/2016 | RLOZANO | RLOZANO | Include approved Development plan and recorded final plat. RTL per LJT (see full review) | | CO Springs DRE | 900086 |
Zoning/Planning | Original | / | 8/31/2016 | | CSUAPPSPRM | Location = Zoning/Planning by CSUAPPSPRM | lmpope | Zoning/Planning | 900002 |
CSU Contract Admin. | Original | D | 8/31/2016 | CSUAPPSPRM | CSUAPPSPRM | Requires submittal/approval of Commercial Water Meter Sizing Form and payment of development charges/fees. Contact Customer Contract Administration at 719-668-8111. LMP | lmpope | CSU Contract Admin. | 900001 |
CSU Contract Admin. | Original | / | 8/30/2016 | | KENYATTA | Location = CSU Contract Admin. by KENYATTA | | CSU Contract Admin. | 899793 |
Plan Coordinator | Original | / | 8/30/2016 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 899728 |
Plumbing | Original | D | 8/30/2016 | TCRIPPEN | TCRIPPEN | elevator sump to drain indirect to the sanitary waste, our rain fall here is 3 inches per hour, provide square footage at each roof drain for sizing, plan should show under ground only remove unused items. /////Tim See table on P-402///// for square footage roof drains | | Plumbing | 899727 |
Plumbing | Original | / | 8/30/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Plumbing | 899603 |
Plumbing | Original | / | 8/30/2016 | | DALEH | Location = Plumbing by DALEH | | Plumbing | 899602 |
Mechanical | Original | N | 8/30/2016 | DALEH | DALEH | | | Mechanical | 899601 |
Mechanical | Original | / | 8/30/2016 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 899578 |
Plan Coordinator | Original | / | 8/30/2016 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 899536 |
Construction | Original | D | 8/30/2016 | DANM | DANM | Provide area calculations showing automatic sprinkler increase Provide IECC Commercial Certificate for envelope compliance (to indicate if there will be foundation/slab insulation See plans for any additional comments Walk-through review OK | | Construction | 899533 |
Construction | Original | / | 8/30/2016 | DANM | DANM | In Current Review by DANM | | Construction | 899452 |
Electrical | Original | A | 8/29/2016 | SHELBY | SHELBY | Underground only | | Electrical | 899405 |
Construction | Original | / | 8/29/2016 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 899308 |
Plan Coordinator | Original | / | 8/29/2016 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 899307 |
Enumeration | Original | A | 8/29/2016 | AMY | AMY | PLATTED ADDRESS IS 3480 VINEYARD PARK DRIVE, DEVELOPMENT PLAN CHANGED, ACCESS TO LOT CHANGED TO JANITELL ROAD THEREFORE,THE ADDRESS CHANGED-SEE ATTACHED ADDRESS CHANGE DOCUMENTATION WITH CODE STUDY FORM. SITE PLAN PAGE C-200 | | Enumeration | 899306 |
Enumeration | Original | / | 8/29/2016 | AMY | AMY | In Current Review by AMY | | Enumeration | 899291 |
Floodplain | Original | N | 8/29/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 899275 |