CO Springs Fire | Original | A | 1/27/2017 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas | csfdit | CO Springs Fire | 933008 |
Electrical | Original | A | 1/23/2017 | SHELBY | SHELBY | | | Electrical | 931488 |
Mechanical | Original | A | 1/19/2017 | JUSTINC | JUSTINC | As noted | | Mechanical | 930931 |
Plumbing | Original | A | 1/19/2017 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 930849 |
Electronic Plan | Original | / | 1/19/2017 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 930821 |
Construction | Original | A | 1/18/2017 | SHELLEY | SHELLEY | | | Construction | 930680 |
Resubmittal 2 | Original | / | 1/18/2017 | GITA | GITA | Resubmittal #2 | | Resubmittal 2 | 930655 |
Health Dept. | Original | A | 1/5/2017 | HEALTHDEPT | HEALTHDEPT | Approved in plan review. A pre-operational inspection will be required before final approval for opening is granted. Rebecca Nielsen 575-8965 | rnielsen | Health Dept. | 928309 |
Health Dept. | Original | / | 1/5/2017 | HEALTHDEPT | HEALTHDEPT | | rnielsen | Health Dept. | 928301 |
CO Springs Fire | Original | D | 12/20/2016 | CSFIRE | CSFIRE | (see full review) | csfdit | CO Springs Fire | 925306 |
Mechanical | Original | D | 12/13/2016 | JUSTINC | JUSTINC | How complying with 09' IFGC 303.3 for water heater in storage room? (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 923851 |
Plumbing | Original | A | 12/13/2016 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 923838 |
Electronic Plan | Original | / | 12/13/2016 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 923831 |
Construction | Original | D | 12/13/2016 | SHELLEY | SHELLEY | This is a change of occupancy to a combined A2-A3.
Splice to interior finish for correct orientation of restrooms required prior to approval. Panic hardware is required for A occupancies serving occupant loads greater than 50. Only 1 MAIN ENTRY DOOR may meet 1008.1.9.3 #2. See plan.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 923681 |
Resubmittal 1 | Original | / | 12/13/2016 | GITA | GITA | Resubmittal #1 | | Resubmittal 1 | 923654 |
Hazmat | Original | N | 12/1/2016 | CSFIRE | CSFIRE | | wtaylor | Hazmat | 921429 |
CO Springs Fire | Original | D | 12/1/2016 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 921428 |
Electrical | Original | A | 11/22/2016 | SHELBY | SHELBY | | | Electrical | 919648 |
Mechanical | Original | D | 11/18/2016 | JUSTINC | JUSTINC | Mechanical review incomplete pending construction reviewer comments (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 918885 |
CO Springs DRE | Original | N | 11/18/2016 | MMCCONNELL | MMCCONNELL | interior remodel. (see full review) | | CO Springs DRE | 918729 |
Water Division | Original | N | 11/17/2016 | CSUREVIEW | CSUREVIEW | No new service lines proposed CQ | cquinn_ds | Water Division | 918510 |
Waste Water Div | Original | N | 11/17/2016 | CSUREVIEW | CSUREVIEW | No new service lines proposed CQ | cquinn_ds | Waste Water Div | 918507 |
Plumbing | Original | D | 11/17/2016 | TCRIPPEN | TCRIPPEN | Pending on constructions review maybe a change of occupancy ? (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 918389 |
Construction | Original | D | 11/16/2016 | SHELLEY | SHELLEY | Art studios are A3 occupancies - interior finish was a B occupancy - clarify as this may be a change of occupancy and revise code study form to match; restroom elements appear in a different orientation that the interior finish; Missing sheet LSP 1.1; FRT required at ALL wood elements in a IIB building; panic hardware?; see plans for all comments; (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 918326 |
Electronic Plan | Original | / | 11/16/2016 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 918128 |
Enumeration | Original | A | 11/15/2016 | BRENT | BRENT | site plan on page LSP1.1 | | Enumeration | 917954 |
Enumeration | Original | D | 11/15/2016 | BRENT | BRENT | include a detailed site plan showing separation of all tenant spaces in the building with addressing and area of work highlighted. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 917904 |
Floodplain | Original | N | 11/15/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 917732 |
Floodplain | Original | N | 11/15/2016 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 917733 |