Construction | Splice 02/12/19 | A | 2/12/2019 | DANM | DANM | Revise UL listing to V455; remove wall/door at lobby | | Construction | 1158298 |
Out to Review | Splice 02/12/19 | / | 2/12/2019 | BECKYA | BECKYA | | | Out to Review | 1158276 |
Mechanical | Splice 01/31/19 | A | 1/31/2019 | JUSTINC | JUSTINC | Revised gas | | Mechanical | 1154763 |
Out to Review | Splice 01/31/19 | / | 1/31/2019 | BECKYA | BECKYA | | | Out to Review | 1154751 |
Construction | Splice 01/04/19 | A | 1/4/2019 | BPHILLIPS | BPHILLIPS | Added restrooms to work scope. | | Construction | 1147066 |
Out to Review | Splice 01/04/19 | / | 1/4/2019 | BECKYA | BECKYA | | | Out to Review | 1147054 |
Out to Review | 10/12/2018 | / | 12/20/2018 | SCANNING | SCANNING | Picked up by Steve Kenyon (719) 482-4165 Side note: Steve took a good look at the plan pages to ensure it was the splice he needed to pick up. -J3- | | Out to Review | 1143907 |
Scanned/Finished Bin | 10/12/2018 | / | 12/19/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1143173 |
To Be Scanned Bin | 10/12/2018 | / | 12/17/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1142012 |
Plan Coordinator | 10/12/2018 | / | 12/17/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1142000 |
Construction | 10/12/2018 | A | 12/17/2018 | MICHAELA | MICHAELA | Revise foundation design - architectural modifications | | Construction | 1141999 |
Construction | 10/12/2018 | / | 12/14/2018 | | GITA | Location = Construction by GITA | | Construction | 1141861 |
Plumbing | 10/12/2018 | A | 12/14/2018 | SHANEN | SHANEN | relocated 4" waste | | Plumbing | 1141845 |
Mechanical | 10/12/2018 | A | 12/14/2018 | SHANEN | SHANEN | Delta5 | | Mechanical | 1141837 |
Out to Review | Splice 07/12/18 | / | 12/12/2018 | JANE | JANE | | | Out to Review | 1140922 |
Out to Review | 10/12/2018 | / | 12/12/2018 | JANE | JANE | Steve 719 482 4165 | | Out to Review | 1140918 |
Finished Bin | 10/12/2018 | / | 10/22/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1122479 |
Plan Coordinator | 10/12/2018 | / | 10/22/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1122318 |
Mechanical | 10/12/2018 | D | 10/22/2018 | DALEH | DALEH | see comments about deltas on all sheets need hand written comments back on new sheets walk ok (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1122317 |
Mechanical | 10/12/2018 | / | 10/22/2018 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1122310 |
Mechanical | 10/12/2018 | / | 10/19/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1122154 |
Plan Coordinator | 10/12/2018 | / | 10/19/2018 | | BERTHA | Location = Plan Coordinator by BERTHA | | Plan Coordinator | 1122111 |
Electrical | 10/12/2018 | A | 10/19/2018 | BERTHA | BERTHA | Revised lighting and light fixture schedule. | | Electrical | 1122110 |
Electrical | 10/12/2018 | / | 10/19/2018 | BERTHA | BERTHA | In Current Review by BERTHA | | Electrical | 1121994 |
Electrical | 10/12/2018 | / | 10/12/2018 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1119712 |
Plan Coordinator | 10/12/2018 | / | 10/12/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1119624 |
Construction | 10/12/2018 | D | 10/12/2018 | MICHAELA | MICHAELA | Provide additional soils reporting for spread footer type foundation to include allowable bearing Walk-through with Michael only or resubmit (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1119623 |
Construction | 10/12/2018 | / | 10/12/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1119612 |
Construction | 10/12/2018 | / | 10/12/2018 | | JANE | Location = Construction by JANE | | Construction | 1119598 |
Scanned/Finished Bin | Splice 10/4/18 | / | 10/8/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1117316 |
To Be Scanned Bin | Splice 07/12/18 | / | 10/5/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1116999 |
CO Springs Fire | Splice 07/12/18 | A | 10/5/2018 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas (see full review) | csfdit | CO Springs Fire | 1116974 |
Plumbing | Splice 10/4/18 | A | 10/4/2018 | TCRIPPEN | TCRIPPEN | Added 1-1/2 water entry, rerouted waste line | | Plumbing | 1116588 |
Out to Review | Splice 10/4/18 | / | 10/4/2018 | BECKYA | BECKYA | | | Out to Review | 1116572 |
Fire | Splice 07/12/18 | / | 9/27/2018 | | SCANNING | Location = Fire by SCANNING | | Fire | 1114653 |
Plan Coordinator | Splice 07/12/18 | / | 9/27/2018 | | ROBERTV | Location = Plan Coordinator by ROBERTV | | Plan Coordinator | 1114618 |
Elevators | Splice 07/12/18 | A | 9/27/2018 | ROBERTV | ROBERTV | Thyssenkrupp Endura MRL - No Emergency Power. BBH-1 has been changed to a Raywall F3920-96C
Note: Fire Department to determine requirements for Fire Sprinkler Locations, Fire Initiating Devices and Shunt Trip Breaker requirements | | Elevators | 1114617 |
Elevators | Splice 07/12/18 | / | 9/26/2018 | | SCANNING | Location = Elevators by SCANNING | | Elevators | 1114051 |
Resubmittal 4 | Splice 07/12/18 | / | 9/26/2018 | SCANNING | SCANNING | Resubmittal #4 | | Resubmittal 4 | 1114050 |
Finished Bin | Splice 07/12/18 | / | 9/13/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1109821 |
Plan Coordinator | Splice 07/12/18 | / | 9/13/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1109729 |
Mechanical | Splice 07/12/18 | A | 9/13/2018 | DALEH | DALEH | re-approved | | Mechanical | 1109728 |
Mechanical | Splice 07/12/18 | / | 9/13/2018 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1109593 |
Mechanical | Splice 07/12/18 | / | 9/12/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1109218 |
Plan Coordinator | Splice 07/12/18 | / | 9/12/2018 | | ROBERTV | Location = Plan Coordinator by ROBERTV | | Plan Coordinator | 1109115 |
Elevators | Splice 07/12/18 | D | 9/12/2018 | ROBERTV | ROBERTV | No changes from comments dated 8/29/2018;
(Sheet M-0 and M-1) Provide specific specifications for BBH-1 Baseboard Heater in Elevator Pit, must not be of the open heating element type and must meet NEMA 3R requirements for elevator hoistway/pit locations.
PPRBD Note: Elevator has been changed to Thyssenkrupp Endura MRL. Fire Department to determine requirements for Fire Sprinkler Locations, Fire Initiating Devices and Shunt Trip Breaker requirements.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1109114 |
Elevators | Splice 07/12/18 | / | 9/12/2018 | | JANE | Location = Elevators by JANE | | Elevators | 1109078 |
Finished Bin | Splice 07/12/18 | / | 9/11/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1108613 |
CO Springs Fire | Splice 07/12/18 | D | 9/10/2018 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas
Provide a Utility Service Plan for the new fire sprinkler service line. (see full review) | csfdit | CO Springs Fire | 1108054 |
Fire | Splice 07/12/18 | / | 8/31/2018 | | SCANNING | Location = Fire by SCANNING | | Fire | 1105718 |
Plan Coordinator | Splice 07/12/18 | / | 8/31/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1105697 |
Mechanical | Splice 07/12/18 | A | 8/31/2018 | DALEH | DALEH | | | Mechanical | 1105696 |
Mechanical | Splice 07/12/18 | / | 8/29/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1105091 |
Plan Coordinator | Splice 07/12/18 | / | 8/29/2018 | | ROBERTV | Location = Plan Coordinator by ROBERTV | | Plan Coordinator | 1105007 |
Elevators | Splice 07/12/18 | D | 8/29/2018 | ROBERTV | ROBERTV | (Sheet M-0 and M-1) Provide specific specifications for BBH-1 Baseboard Heater in Elevator Pit, must not be of the open heating element type and must meet NEMA 3R requirements for elevator hoistway/pit locations.
PPRBD Note: Elevator has been changed to Thyssenkrupp Endure MRL. Fire Department to determine requirements for Fire Sprinkler Locations, Fire Initiating Devices and Shunt Trip Breaker requirements.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1104999 |
Elevators | Splice 07/12/18 | / | 8/28/2018 | | SCANNING | Location = Elevators by SCANNING | | Elevators | 1104658 |
Plan Coordinator | Splice 07/12/18 | / | 8/28/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1104624 |
Construction | Splice 07/12/18 | A | 8/28/2018 | MICHAELA | MICHAELA | Add shaft framing | | Construction | 1104623 |
Construction | Splice 07/12/18 | / | 8/28/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1104614 |
Construction | Splice 07/12/18 | / | 8/28/2018 | | JANE | Location = Construction by JANE | | Construction | 1104585 |
Resubmittal 3 | Splice 07/12/18 | / | 8/28/2018 | JANE | JANE | Resubmittal #3 | | Resubmittal 3 | 1104583 |
Out to Review | Splice 07/12/18 | / | 8/24/2018 | JANE | JANE | 719 484 0480 Nick | | Out to Review | 1103700 |
Finished Bin | Splice 07/12/18 | / | 8/20/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1101436 |
Mechanical | Splice 07/12/18 | / | 8/20/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1101425 |
Plan Coordinator | Splice 07/12/18 | / | 8/20/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1101404 |
Construction | Splice 07/12/18 | D | 8/20/2018 | MICHAELA | MICHAELA | Although we know the building was formerly II-A construction, it is no longer, therefore you will need to provide a UL listed assembly (or equal) for the floor supporting the shaft as well as the walls supporting the floor. Per 716.6.3 Shaft “F” does not require shaft protection. The annular space around the duct must be filled with an approved fire resistance-rated material. Per 716.6.3 Shafts E and G do require a shaft and per 708.11 either the shaft needs to continue to the bottom floor where the ductwork could penetrate the side wall with a fire damper or a fire damper needs to be installed in the floor at the lowest level of the duct penetration.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1101403 |
Construction | Splice 07/12/18 | / | 8/20/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1101312 |
Construction | Splice 07/12/18 | / | 8/17/2018 | | MATTHEWM | Location = Construction by MATTHEWM | | Construction | 1101178 |
Resubmittal 2 | Splice 07/12/18 | / | 8/17/2018 | MATTHEWM | MATTHEWM | Resubmittal #2 | | Resubmittal 2 | 1101177 |
Construction | Splice 07/12/18 | D | 8/17/2018 | BPHILLIPS | BPHILLIPS | Fire barrier resting on platform must have supporting construction with equivalent fire protective rating. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1101105 |
Construction | Splice 07/12/18 | D | 8/14/2018 | DANM | DANM | Darken background so floor plan shows through Provide typical section through new shaft construction showing vertical continuity code compliance Walk-through review OK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1099617 |
Out to Review | Splice 07/12/18 | A | 8/2/2018 | | CSFIRE | Location = Out to Review by CSFIRE Plans given back to Nick Sallecchia | fdjah74 | Out to Review | 1095766 |
Fire | Splice 07/12/18 | / | 8/1/2018 | | SCANNING | Location = Fire by SCANNING | | Fire | 1095351 |
Plan Coordinator | Splice 07/12/18 | / | 8/1/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1095321 |
Mechanical | Splice 07/12/18 | D | 8/1/2018 | DALEH | DALEH | cfm's at register locations typ how protecting floor penetrations that don't have shafts typ please provide a roof plan for new work see plans for complete green lines return green lines with next review
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1095320 |
Construction | Splice 07/12/18 | D | 8/1/2018 | MICHAELA | MICHAELA | Provide letter from an engineer indicating that the roof structure is adequate for new rooftop mechanical units Clarify how ductwork floor penetrations are being protected (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1095173 |
Mechanical | Splice 07/12/18 | / | 7/31/2018 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1094681 |
Mechanical | Splice 07/12/18 | / | 7/30/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1094584 |
Resubmittal 1 | Splice 07/12/18 | / | 7/30/2018 | GITA | GITA | Resubmittal #1 MECHANICAL ONLY | | Resubmittal 1 | 1094579 |
Plumbing | Splice 07/12/18 | A | 7/30/2018 | DALEH | DALEH | | | Plumbing | 1094572 |
Out to Review | Splice 07/12/18 | / | 7/30/2018 | NELIDA | NELIDA | Nick 719-484-0480 | | Out to Review | 1094541 |
Finished Bin | Splice 07/12/18 | / | 7/25/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1092965 |
CO Springs Fire | Splice 07/12/18 | D | 7/24/2018 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas (see full review) | csfdit | CO Springs Fire | 1092598 |
Fire | Splice 07/12/18 | / | 7/18/2018 | | SCANNING | Location = Fire by SCANNING | | Fire | 1090779 |
Plan Coordinator | Splice 07/12/18 | / | 7/18/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1090765 |
Mechanical | Splice 07/12/18 | D | 7/18/2018 | DALEH | DALEH | remove any clouds on the drawings all mechanical sheets will be reviewed as an entire new review for mechanical due to changing design professionals one engineer cant cloud another engineers drawings. no review no walk (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1090764 |
Mechanical | Splice 07/12/18 | / | 7/18/2018 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1090744 |
Mechanical | Splice 07/12/18 | / | 7/18/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1090741 |
Electrical | Splice 07/12/18 | A | 7/17/2018 | SHELBY | SHELBY | | | Electrical | 1090412 |
Plan Coordinator | Splice 07/12/18 | / | 7/16/2018 | SHELBY | SHELBY | In Current Review by SHELBY | | Plan Coordinator | 1090109 |
Plan Coordinator | Splice 07/12/18 | / | 7/16/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1090107 |
Electrical | Splice 07/12/18 | D | 7/16/2018 | SHELBY | SHELBY | Include sheets with changes only. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1090106 |
Plumbing | Splice 07/12/18 | D | 7/16/2018 | TCRIPPEN | TCRIPPEN | See chapter 3 and sections 301.6 and 1003.4 the sump shall discharge indirectly to the sanitary waste, RBD. spent 30 minutes (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1089957 |
Electrical | Splice 07/12/18 | / | 7/13/2018 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1089170 |
Plan Coordinator | Splice 07/12/18 | / | 7/13/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1089162 |
Construction | Splice 07/12/18 | A | 7/13/2018 | MICHAELA | MICHAELA | Add demo and sprinkler system - revise roof framing | | Construction | 1089161 |
Construction | Splice 07/12/18 | / | 7/12/2018 | | GITA | Location = Construction by GITA | | Construction | 1089041 |
Gas/Elec. Utils | Original | N | 6/13/2018 | CSUREVIEW | CSUREVIEW | AJ 6/13/18 | ajuvera | Gas/Elec. Utils | 1079505 |
CSU Contract Admin. | Original | N | 6/13/2018 | CSUAPPSPRM | CSUAPPSPRM | | aguerin | CSU Contract Admin. | 1079498 |
CSU Contract Admin. | Original | / | 6/13/2018 | CSUAPPSPRM | CSUAPPSPRM | | Benglish | CSU Contract Admin. | 1079480 |
City Engr | Original | N | 12/4/2017 | PMORRIS | PMORRIS | | | City Engr | 1017527 |
Mechanical | Original | A | 12/1/2017 | DALEH | DALEH | | | Mechanical | 1017104 |
Resubmittal 4 | Original | / | 11/30/2017 | BECKYA | BECKYA | Resubmittal #4 | | Resubmittal 4 | 1016806 |
Mechanical | Original | D | 11/27/2017 | DALEH | DALEH | provide fire damper listings that match with the wall listing (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1015675 |
Plumbing | Original | A | 11/27/2017 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 1015525 |
Electronic Plan | Original | / | 11/27/2017 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1015483 |
Water Division | Original | A | 11/27/2017 | CSUREVIEW | CSUREVIEW | Comments addressed. JPN | jnoble | Water Division | 1015396 |
Construction | Original | A | 11/22/2017 | MICHAELA | MICHAELA | | | Construction | 1015370 |
Resubmittal 3 | Original | / | 11/22/2017 | SHELLEY | SHELLEY | Resubmittal #3 | | Resubmittal 3 | 1015335 |
CO Springs Fire | Original | A | 11/20/2017 | CSFIRE | CSFIRE | 2-WAY ELEVATOR COMMUNICATIONS/ ELEVATOR RECALL DEFERRED SUBMITALS (see full review) | csfdit | CO Springs Fire | 1014379 |
Water Division | Original | D | 11/16/2017 | CSUREVIEW | CSUREVIEW | - Comments not addressed. - Provide a copy of the approved Utility Service Plan with submittal. - Additionally, need to have an approved Backflow Assembly Review Form. Contact Chelsa Shull at 719-668-8755 or Holly Link at 719-668-4733 with any questions. JPN | jnoble | Water Division | 1013527 |
Mechanical | Original | D | 11/14/2017 | DALEH | DALEH | need construction comments prior to mechanical review (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1012701 |
CO Springs DRE | Original | A | 11/14/2017 | GSANDERS | GSANDERS | No changes on site plan from original approval on 7/31/2017 (see full review) | | CO Springs DRE | 1012585 |
Electrical | Original | A | 11/14/2017 | SHELBY | SHELBY | | | Electrical | 1012544 |
Zoning/Planning | Original | / | 11/13/2017 | GSANDERS | GSANDERS | In Current Review by GSANDERS | | Zoning/Planning | 1012466 |
Plumbing | Original | D | 11/13/2017 | TCRIPPEN | TCRIPPEN | A floor sink is required for sump pump discharge (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1012068 |
Construction | Original | D | 11/9/2017 | MICHAELA | MICHAELA | Revise descriptions of rated assemblies Revise doors as desired per notes (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1012020 |
Resubmittal 2 | Original | / | 11/8/2017 | BECKYA | BECKYA | Resubmittal #2 | | Resubmittal 2 | 1011440 |
Electrical | Original | D | 10/2/2017 | SHELBY | SHELBY | Please see previous review comment. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1000491 |
CO Springs Fire | Original | D | 10/2/2017 | CSFIRE | CSFIRE | | rpeterson | CO Springs Fire | 1000146 |
Waste Water Div | Original | A | 9/25/2017 | CSUREVIEW | CSUREVIEW | No apparent conflicts. ERW | ewidrick | Waste Water Div | 998487 |
Water Division | Original | D | 9/25/2017 | CSUREVIEW | CSUREVIEW | - Comments not addressed. - Provide a copy of the approved Utility Service Plan with submittal. - Additionally, need to coordinate Backflow Assembly Review with Holly Link (719-668-4733). ERW | ewidrick | Water Division | 998485 |
Water Division | Original | D | 9/25/2017 | CSUREVIEW | CSUREVIEW | - Comments not addressed. - Provide a copy of the approved Utility Service Plan with submittal. - Additionally, need to coordinate Backflow Assembly Review with Holly Link (719-668-4733). ERW | ewidrick | Water Division | 998479 |
Mechanical | Original | D | 9/25/2017 | DALEH | DALEH | see red lines need commercial comments addressed prior to mechanical (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 998132 |
Plumbing | Original | A | 9/25/2017 | TCRIPPEN | TCRIPPEN | approved as noted floor sink required not floor drain. | | Plumbing | 998102 |
Electronic Plan | Original | / | 9/25/2017 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 998099 |
Elevators | Original | A | 9/22/2017 | ERIC | ERIC | Otis Hydrofit machineroomless hydraulic elevator | | Elevators | 997923 |
Construction | Original | D | 9/22/2017 | SHELLEY | SHELLEY | Incorrect listings and table provided; supporting construction must also be protected due to type of construction; clarify the use of fire barriers in corridors where fire partitions are required - if barriers, provide continuity details and verify all doors (new and existing) comply, if partitions, verify all doors comply (new and existing) for all new walls and walls not previously part of the rated corridor system; see plans for all comments. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 997917 |
Resubmittal 1 | Original | / | 9/19/2017 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 996749 |
CO Springs Fire | Original | D | 8/9/2017 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 984941 |
Electrical | Original | D | 8/1/2017 | SHELBY | SHELBY | Show service lateral size ,type, and quantity on one line. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 983088 |
Mechanical | Original | D | 7/31/2017 | JUSTINC | JUSTINC | Plan submitted as ADDITION THRU FINISH. Provide complete mechanical scope. Mechanical review incomplete pending construction reviewer comments. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 982629 |
CO Springs DRE | Original | A | 7/31/2017 | GSANDERS | GSANDERS | per Matt Fitzsimmons and RBT. (see full review) | | CO Springs DRE | 982523 |
Plumbing | Original | D | 7/31/2017 | TCRIPPEN | TCRIPPEN | Sump to be indirect to sanitary waste floor sink, or mop sink okay (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 982430 |
Electronic Plan | Original | / | 7/31/2017 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 982404 |
Elevators | Original | D | 7/31/2017 | ROBERTV | ROBERTV | Plans indicate Otis Hydrofit but also show conventional style jack in Architectural drawings. Provide site specific Elevator Shop Drawings (Please index and incorporate shop drawings within plan set). Electrical page E-1 indicates lighting required for Otis Hydrofit style Elevator if being installed, Also need to show Elevator Sump Pit size and construction detail in plan set. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 982378 |
Zoning/Planning | Original | / | 7/31/2017 | GSANDERS | GSANDERS | In Current Review by GSANDERS | | Zoning/Planning | 982287 |
Water Division | Original | D | 7/28/2017 | CSUREVIEW | CSUREVIEW | Initial review indicates that proposed addition will impact existing utilities. Please contact Utilities Development Services at 668-8111 to discuss potential Development/Utility Service Plan requirements. Additionally, need to provide a Backflow Assembly Plan Review Form. It can be found at https://www.csu.org/CSUDocuments/backflowdomesticform.pdf. Please contact Holly Link at 719-668-4733 to discuss proper backflow requirements. JPN | jnoble | Water Division | 982260 |
Waste Water Div | Original | D | 7/28/2017 | CSUREVIEW | CSUREVIEW | Initial review indicates that proposed addition will impact existing utilities. Please contact Utilities Development Services at 668-8111 to discuss potential Development/Utility Service Plan requirements. JPN | jnoble | Waste Water Div | 982254 |
Hazmat | Original | N | 7/28/2017 | CSFIRE | CSFIRE | No hazmat in scope of work. Work only modifies entry area. | smanning | Hazmat | 982138 |
Construction | Original | D | 7/27/2017 | MICHAELA | MICHAELA | Type of construction is II-A -provide listed assemblies accordingly Clarify if this is a single tenant building Main level wall demolition affects rated assemblies - clarify how this results in compliant egress Addition triggers requirement for height and area calculations Second level exiting does not seem compliant Second floor demo seems to eliminate a suite - please clarify Main level section through exit enclosure plan view does not match section
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 981888 |
Electronic Plan | Original | / | 7/27/2017 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 981493 |
Enumeration | Original | A | 7/24/2017 | BRENT | BRENT | | | Enumeration | 980308 |
Floodplain | Original | N | 7/18/2017 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 978554 |
Floodplain | Original | N | 7/18/2017 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 978553 |