Construction | Splice 02/05/21 | A | 2/8/2021 | MICHAELA | MICHAELA | Add window | | Construction | 1452657 |
Electronic Plan | Splice 02/05/21 | / | 2/8/2021 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1452308 |
Mechanical | Original | A | 9/23/2019 | DALEH | DALEH | | | Mechanical | 1238360 |
Construction | Original | A | 9/23/2019 | MICHAELA | MICHAELA | | | Construction | 1238324 |
Out to Review | Original | / | 7/19/2019 | RITA | RITA | Dawne | | Out to Review | 1214898 |
Finished Bin | Original | / | 7/18/2019 | | SCANNING | Location = Finished Bin by SCANNING (Located in Small Finished bin) | | Finished Bin | 1214506 |
Plan Coordinator | Original | / | 7/18/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1214428 |
Mechanical | Original | D | 7/18/2019 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Provide IECC certificate As this is a forced air system must provide manuals J,S, and D from Wrightsoft or Elite programs. The only other option is to have a mechanical engineer stamp every mechanical sheet submitted. I revised the HVAC equipment certificate to show the correct derate info.
See attached handout for duct design requirements and a list of some HVAC designers if you wish to use.
Comments not addressed from 1st review. NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1214424 |
Mechanical | Original | / | 7/18/2019 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1214339 |
Plan Coordinator | Original | / | 7/18/2019 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1214333 |
Construction | Original | D | 7/18/2019 | MICHAELA | MICHAELA | Still missing IECC certificate Window list does not clearly indicate size and operation of windows Inspection notes: Owner will need to prove that walls on slab are floating Owner will need to prove insulation values are code compliant once IECC certificate is provided Walk-through OK (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1214331 |
Construction | Original | / | 7/18/2019 | | RITA | Location = Construction by RITA | | Construction | 1214290 |
Resubmittal 1 | Original | / | 7/18/2019 | RITA | RITA | Resubmittal #1 | | Resubmittal 1 | 1214289 |
County Zoning | Original | A | 10/4/2018 | DSDRANGEL | DSDRANGEL | | | County Zoning | 1116635 |
Out to Review | Original | / | 8/10/2018 | RITA | RITA | Dawne 719-660-9273 | | Out to Review | 1099018 |
Finished Bin | Original | / | 5/14/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1068165 |
Out to Review | Original | / | 5/14/2018 | DSDRANGEL | DSDRANGEL | PPRBD | | Out to Review | 1068161 |
County Zoning | Original | D | 5/14/2018 | DSDRANGEL | DSDRANGEL | REQUIRES US FISH AND WILDLIFE CLEARANCE | | County Zoning | 1068160 |
Zoning/Planning | Original | / | 5/11/2018 | DSDRANGEL | DSDRANGEL | In Current Review by DSDRANGEL | | Zoning/Planning | 1067859 |
Zoning/Planning | Original | / | 5/11/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1067489 |
Plumbing | Original | A | 5/11/2018 | TCRIPPEN | TCRIPPEN | The following must be done before can be done Remove toilet clean flange off bolt or make sure flange is bolted to floor system,Remove shower trim around Handel, need 12 x 12 inch opening at each sink through drywall and cabinet , only one fixture per 1/2 water line no 1/2 tees allowed inspection holes maybe required by Inspectors | | Plumbing | 1067470 |
Plumbing | Original | / | 5/10/2018 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1067205 |
Plan Coordinator | Original | / | 5/10/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1066946 |
Mechanical | Original | D | 5/10/2018 | JUSTINC | JUSTINC | Mechanical review incomplete
List type of heating equipment on HVAC equipment certificate
Sign and date HVAC equipment certificate
It appears that the heat system is to be a warm air furnace with duct serving the rooms required to have heat. If this is correct the provided heatloss calculation will not be acceptable. A full heatloss calculation using "WRIGHTSOFT or ELITE" heatloss program with a complete duct design is required for mechanical review
A dryer vent termination has been indicated on the side elevation? Cannot locate on floor plan location of washer and dryer. Indicate on plan.
Must derate equipment on HVAC equipment certificate also for efficency. Indicate efficency also on HVAC equipment certificate.
Provide all equipment cutsheets marked for the unit selections used for this system.
REVIEW STOPPED NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1066945 |
Mechanical | Original | / | 5/10/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1066905 |
Mechanical | Original | / | 5/9/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1066832 |
Plan Coordinator | Original | / | 5/9/2018 | | BERTHA | Location = Plan Coordinator by BERTHA | | Plan Coordinator | 1066755 |
Electrical | Original | A | 5/9/2018 | BERTHA | BERTHA | Remove all devices prior to inspection. | | Electrical | 1066754 |
Electrical | Original | / | 5/9/2018 | BERTHA | BERTHA | In Current Review by BERTHA | | Electrical | 1066668 |
Electrical | Original | / | 5/9/2018 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1066399 |
Plan Coordinator | Original | / | 5/9/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1066350 |
Construction | Original | D | 5/9/2018 | MICHAELA | MICHAELA | Provide an engineers letter for: 10 The foundation being adequate and frost protected 2) The design of the pole structure 3) The roof structure including the welded connections Verify walls on slab are floating Indicate the size and operation of all windows List of show appliances Show all bathroom fixtures No walk-through
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1066349 |
Construction | Original | / | 5/9/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1066326 |
Construction | Original | / | 5/8/2018 | | SCANNING | Location = Construction by SCANNING | | Construction | 1065882 |
Plan Coordinator | Original | / | 5/8/2018 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 1065864 |
Floodplain | Original | N | 5/8/2018 | AMY | AMY | FLOODPLAIN COMES APPROX. 113.OO FT IN ON THE EAST PROPERTY LINE. WORK NOT IN THE FLOODPLAIN AREA. | | Floodplain | 1065862 |
Enumeration | Original | A | 5/8/2018 | AMY | AMY | | | Enumeration | 1065860 |
Enumeration | Original | / | 5/8/2018 | AMY | AMY | In Current Review by AMY | | Enumeration | 1065858 |
Floodplain | Original | / | 5/3/2018 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 6110001010) | | Floodplain | 1064631 |