Construction | Splice 04/24/19 | A | 4/25/2019 | LBENNETT | LBENNETT | Revised exterior wall framing | | Construction | 1182883 |
Resubmittal 1 | Splice 04/24/19 | / | 4/25/2019 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1182868 |
Construction | Splice 04/24/19 | D | 4/24/2019 | SHELLEY | SHELLEY | Detail referenced for exterior wall construction references 2x8 or 2x6; per owner 2x4 is being used. Detail needs to match. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1182425 |
Out to Review | Splice 04/24/19 | / | 4/24/2019 | BECKYA | BECKYA | | | Out to Review | 1182407 |
Plan Coordinator | Original | / | 9/27/2018 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1114638 |
Mechanical | Original | A | 9/27/2018 | TCRIPPEN | TCRIPPEN | okay | | Mechanical | 1114636 |
Finished Bin | Original | / | 9/27/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1114306 |
Plan Coordinator | Original | / | 9/26/2018 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1114245 |
Mechanical | Original | D | 9/26/2018 | TCRIPPEN | TCRIPPEN | equipment certificate is incomplete see red lines (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1114244 |
Mechanical | Original | / | 9/26/2018 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Mechanical | 1114115 |
Mechanical | Original | / | 9/25/2018 | | NELIDA | Location = Mechanical by NELIDA | | Mechanical | 1113661 |
Resubmittal 2 | Original | / | 9/25/2018 | NELIDA | NELIDA | Resubmittal #2 9/25/18 | | Resubmittal 2 | 1113660 |
Health Dept. | Original | / | 9/24/2018 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 1113374 |
Plan Coordinator | Original | / | 9/24/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1113275 |
Mechanical | Original | D | 9/24/2018 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Comments from 1st review have not all been addressed.
MUST indicate address on EVERY sheet. Still missing 2nd sheet for whole house ventilation from equipment certificate Missing furnace data on HVAC equipment certificate equipment cutsheets still do not indicate unit selections
Will require full mechanical review with next submittal
REVIEW STOPPED NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1113273 |
Mechanical | Original | / | 9/24/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1113225 |
Mechanical | Original | / | 9/24/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1113219 |
Plan Coordinator | Original | / | 9/24/2018 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 1113156 |
Construction | Original | A | 9/24/2018 | DANM | DANM | | | Construction | 1113155 |
Construction | Original | / | 9/24/2018 | DANM | DANM | In Current Review by DANM | | Construction | 1113127 |
Construction | Original | / | 9/24/2018 | | RITA | Location = Construction by RITA | | Construction | 1113075 |
Resubmittal 1 | Original | / | 9/24/2018 | RITA | RITA | Resubmittal #1 | | Resubmittal 1 | 1113073 |
Plan Coordinator | Original | / | 9/24/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1113036 |
Mechanical | Original | D | 9/24/2018 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Plan submitted to the 2015 code cycle. Missing page 2 of HVAC equipment certificate for whole house ventilation verification Indicate unit selections on equipment cut sheets Indicate address on EVERY sheet Indicate brand of equipment if not shown on equipment cutsheets Verify all R & U values with revised 2015 IECC
No further review at this time Will require full mechanical review with next submittal
NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1113035 |
Mechanical | Original | / | 9/24/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1112994 |
Mechanical | Original | / | 9/21/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1112513 |
Plan Coordinator | Original | / | 9/21/2018 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 1112493 |
Construction | Original | D | 9/21/2018 | DANM | DANM | Incorrect IECC certificate included - should be 2015 Provide engineered truss designs for porch trusses Clarify if attic is finished or unfinished and its use Provide a minimum of one overall building section Clarify attachment of floor joist ledger to structure No walk-through review allowed
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1112492 |
Construction | Original | / | 9/21/2018 | DANM | DANM | In Current Review by DANM | | Construction | 1112449 |
Construction | Original | / | 9/20/2018 | | SCANNING | Location = Construction by SCANNING | | Construction | 1112183 |
Plan Coordinator | Original | / | 9/20/2018 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 1112142 |
Enumeration | Original | A | 9/20/2018 | AMY | AMY | original home totally destroyed in Black Forest Fire 2013 | | Enumeration | 1112140 |
Enumeration | Original | / | 9/20/2018 | | NELIDA | Location = Enumeration by NELIDA | | Enumeration | 1112111 |
County Zoning | Original | A | 7/31/2018 | DSDESPINOZA | DSDESPINOZA | | | County Zoning | 1094929 |
Out to Review | Original | / | 7/31/2018 | RITA | RITA | Catherine 719-482-5933 | | Out to Review | 1094909 |
Floodplain | Original | N | 7/31/2018 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5209001011) | | Floodplain | 1094908 |