Construction | Splice 11/30/21 | A | 12/6/2021 | SHELLEY | SHELLEY | Added decks. | | Construction | 1602952 |
Resubmittal 1 | Splice 11/30/21 | / | 12/3/2021 | AUSTINK | AUSTINK | Resubmittal #1 | | Resubmittal 1 | 1602709 |
Construction | Splice 11/30/21 | D | 11/30/2021 | SHELLEY | SHELLEY | Decks cannot combine frost protected and non-frost protected foundation elements. Decks would need to be completely detached with no frost protection to use 12" deep piers. Specify ledger connection to house. Decks are under patio covers, no change in footprint or lot coverage. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1600326 |
Construction | Splice 06/26/20 | A | 6/26/2020 | LBENNETT | LBENNETT | Revised crawlspace foundation to ICF | | Construction | 1342070 |
Construction | Splice 05/19/20 | A | 6/22/2020 | LBENNETT | LBENNETT | Added missing mono trusses | | Construction | 1339755 |
Construction | Splice 05/19/20 | D | 5/19/2020 | LBENNETT | LBENNETT | Provide an updated framing plan showing the location of these new trusses New trusses do not meet snow load or wind load required New trusses may need to be designed for partial enclosure (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1324446 |
Electronic Plan | Splice 05/19/20 | / | 5/19/2020 | LBENNETT | LBENNETT | In Current Review by LBENNETT | | Electronic Plan | 1324429 |
Scanned/Finished Bin | Original | / | 3/2/2020 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1292434 |
To Be Scanned Bin | Original | / | 3/2/2020 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1292129 |
Plan Coordinator | Original | / | 2/28/2020 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1292096 |
Mechanical | Original | A | 2/28/2020 | TCRIPPEN | TCRIPPEN | okay | | Mechanical | 1292095 |
Mechanical | Original | / | 2/28/2020 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1292021 |
Plan Coordinator | Original | / | 2/28/2020 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1291881 |
Construction | Original | A | 2/28/2020 | SHELLEY | SHELLEY | | | Construction | 1291880 |
Construction | Original | / | 2/28/2020 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1291862 |
Construction | Original | / | 2/26/2020 | | NELIDA | Location = Construction by NELIDA | | Construction | 1290968 |
Resubmittal 4 | Original | / | 2/26/2020 | NELIDA | NELIDA | Resubmittal #4 2/26/20 | | Resubmittal 4 | 1290967 |
Out to Review | Original | / | 2/12/2020 | NELIDA | NELIDA | Trevor 701-729-0101 | | Out to Review | 1285922 |
Finished Bin | Original | / | 2/10/2020 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1284765 |
Plan Coordinator | Original | / | 2/10/2020 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1284684 |
Mechanical | Original | D | 2/10/2020 | TCRIPPEN | TCRIPPEN | per are last conversation all mechanical pages are to have the round seal stamp missing on M1.0 and M 2.0 and missing on the Equipment certificate page 1 and 2 (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1284682 |
Mechanical | Original | / | 2/10/2020 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Mechanical | 1284582 |
Mechanical | Original | / | 2/7/2020 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1284309 |
Plan Coordinator | Original | / | 2/7/2020 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1284219 |
Construction | Original | D | 2/7/2020 | SHELLEY | SHELLEY | Bearing widths on girder trusses not addressed. HGT holdowns do not provide additional bearing width, only uplift. see plans; walk ok. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1284217 |
Construction | Original | / | 2/6/2020 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1284145 |
Construction | Original | / | 2/6/2020 | | JANE | Location = Construction by JANE | | Construction | 1284103 |
Resubmittal 3 | Original | / | 2/6/2020 | JANE | JANE | Resubmittal #3 | | Resubmittal 3 | 1284102 |
Out to Review | Original | / | 1/8/2020 | JANE | JANE | Trevor 701 729 0101 | | Out to Review | 1273833 |
Finished Bin | Original | / | 1/8/2020 | | RITA | Location = Finished Bin by RITA | | Finished Bin | 1273492 |
County Zoning | Original | A | 1/8/2020 | DSDRANGEL | DSDRANGEL | Review Complete. See comments below for: Single Family Dwelling, Driveway, BESQCP (see full review) | | County Zoning | 1273427 |
County Zoning | Original | / | 1/8/2020 | EPCZONING | EPCZONING | Driveway Approved (see full review) | | County Zoning | 1273425 |
County Zoning | Original | / | 1/7/2020 | DSDRANGEL | DSDRANGEL | Single Family Dwelling Approved (see full review) | | County Zoning | 1273302 |
County Zoning | Original | / | 1/6/2020 | DSDRANGEL | DSDRANGEL | BESQCP Approved (see full review) | | County Zoning | 1272781 |
Zoning/Planning | Original | / | 1/6/2020 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1272584 |
Mechanical | Original | / | 1/6/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1272541 |
Mechanical | Original | / | 1/6/2020 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1272540 |
Zoning/Planning | Original | / | 1/6/2020 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1272538 |
Plan Coordinator | Original | / | 1/6/2020 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1272509 |
Mechanical | Original | D | 1/6/2020 | TCRIPPEN | TCRIPPEN | See constructions notes previous comments not addressed heat calculations and all pages for the heat package will require an Engineer stamp not a note? No walk through,
. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1272508 |
Mechanical | Original | / | 1/6/2020 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1272494 |
Plan Coordinator | Original | / | 1/6/2020 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1272481 |
Construction | Original | D | 1/6/2020 | SHELLEY | SHELLEY | Revised rescheck - unheated slab per plans and incorrect values used; floor beams and posts insufficient; floor joist insufficient; several trusses require additional uplift, and/or bearing, and/or posts; still missing 3rd bearing point on AG1 and AG2 trusses; see plans for all comments; no walk. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1272480 |
Construction | Original | / | 1/3/2020 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1272424 |
Construction | Original | / | 1/3/2020 | | GITA | Location = Construction by GITA | | Construction | 1272384 |
Resubmittal 2 | Original | / | 1/3/2020 | GITA | GITA | Resubmittal #2 | | Resubmittal 2 | 1272383 |
Out to Review | Original | / | 12/31/2019 | RITA | RITA | Tom 701-261-1266 | | Out to Review | 1271449 |
Finished Bin | Original | / | 12/31/2019 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1271327 |
Out to Review | Original | / | 12/31/2019 | DSDRANGEL | DSDRANGEL | PPRBD Plan Coordinator | | Out to Review | 1271319 |
County Zoning | Original | D | 12/31/2019 | DSDRANGEL | DSDRANGEL | BESQCP required. Application is enclosed in plan set. | | County Zoning | 1271318 |
Zoning/Planning | Original | / | 12/30/2019 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1271077 |
Plan Coordinator | Original | / | 12/30/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1271049 |
Mechanical | Original | D | 12/30/2019 | JUSTINC | JUSTINC | Need the HVAC equipment cert and the 2nd page to cert. stamped from engineer
WALK OK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1271048 |
Mechanical | Original | / | 12/30/2019 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1270961 |
Plan Coordinator | Original | / | 12/30/2019 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1270943 |
Construction | Original | D | 12/30/2019 | SHELLEY | SHELLEY | Per plans, attached garage is heated - revise rescheck to include in thermal envelope and address slab insulation; Floor joist spans do not meet published design perameters - PE required; floor beams insufficient; clarify bearing wall on garage slab; specify all uplift connections for trusses; several truss bearing issues; girders insufficiently labeled; king studs to match RBC; several hangers missing; too many items to fully list; see plans. no walk. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1270942 |
Construction | Original | / | 12/30/2019 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1270837 |
Construction | Original | / | 12/26/2019 | | SCANNING | Location = Construction by SCANNING | | Construction | 1270035 |
Plan Coordinator | Original | / | 12/26/2019 | | BEND | Location = Plan Coordinator by BEND | | Plan Coordinator | 1270030 |
Enumeration | Original | A | 12/26/2019 | BEND | BEND | | | Enumeration | 1270031 |
Resubmittal 1 | Original | / | 12/23/2019 | JANE | JANE | Resubmittal #1 | | Resubmittal 1 | 1269513 |
Out to Review | Original | / | 11/19/2019 | JANE | JANE | TOm 701 261 1266 | | Out to Review | 1258446 |
Finished Bin | Original | / | 11/19/2019 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1258427 |
Health Dept. | Original | N | 11/19/2019 | HEALTHDEPT | HEALTHDEPT | Not applicable. | karinahunt | Health Dept. | 1258338 |
Health Dept. | Original | / | 11/18/2019 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 1257949 |
Out to Review | Original | / | 11/18/2019 | DSDRANGEL | DSDRANGEL | PPRBD Plan Coordinator | | Out to Review | 1257948 |
County Zoning | Original | D | 11/18/2019 | DSDRANGEL | DSDRANGEL | Per BOA94042 a new dimensional variance will be required for lot size of 3.55 acres. Please call the planner of the day at 719-520-6300 for process information. Once this process has occurred, make enumeration comment changes, and submit a BESQCP. | | County Zoning | 1257946 |
Zoning/Planning | Original | / | 11/18/2019 | DSDRANGEL | DSDRANGEL | In Current Review by DSDRANGEL | | Zoning/Planning | 1257911 |
Zoning/Planning | Original | / | 11/18/2019 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1257879 |
Plan Coordinator | Original | / | 11/18/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1257854 |
Mechanical | Original | D | 11/18/2019 | JUSTINC | JUSTINC | See attached handout with plan set also attached is mechanical plan review notes
NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1257853 |
Mechanical | Original | / | 11/18/2019 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1257738 |
Plan Coordinator | Original | / | 11/18/2019 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1257723 |
Construction | Original | D | 11/18/2019 | SHELLEY | SHELLEY | Clarify crawlspace conditioned, clarify where slab on grade element is and show on rescheck (is garage heated?); All framing information to be on framing plans; framing options not allowed - choose all materials; specify all materials; provide required roof framing plans - see attached checklist; manufacturer truss layout are not accepted in lieu of labeled roof framing; PRELIMINARY STRUCTURAL REVIEW ONLY; Detached garage uses incorrect snow and wind loads. see plans. No walk. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1257722 |
Construction | Original | / | 11/18/2019 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1257691 |
Construction | Original | / | 11/15/2019 | | SCANNING | Location = Construction by SCANNING | | Construction | 1257228 |
Plan Coordinator | Original | / | 11/15/2019 | | BEND | Location = Plan Coordinator by BEND | | Plan Coordinator | 1257193 |
Enumeration | Original | D | 11/15/2019 | BEND | BEND | Please provide site plan with the following information: 1. Address 2. Legal description 3. Tax schedule number 4. North arrow 5. Street name 6. Lot dimensions
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1257192 |
Enumeration | Original | / | 11/15/2019 | BEND | BEND | In Current Review by BEND | | Enumeration | 1257189 |
Floodplain | Original | N | 11/13/2019 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5206000062) | | Floodplain | 1256126 |