PROCESSING....
This is hidden content to make Wave think this is not a heading
Skip to main content
Pikes Peak Regional Building Department
Ensuring life safety and welfare of our community through efficient and consistent application of adopted codes and standards.
Home
Contact
Search
Accessibility
Cart
Sign In
Home
Contact
Search
Accessibility
Cart
Sign In
Plan Details
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Plan #
  
Type
 
Plan
Owner
Address
12850 THIEBAUD LN, COLORADO SPRINGS, CO 80908
Permit #
M70303
Parcel Info
5207003029
Truss P/SF
40 (Elevation: 7,298 Feet)
Project
PV SOLAR ( 8990 WATTS ) (
434
)
Type Of Plan
Normal
Review Type
Single Copy
Fire District
BLACK FOREST FIRE PROTECTION DISTRICT
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 4
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Construction
N
0
C
Construction
Electrical
A
0
E
Electrical
Floodplain
N
W
Floodplain
County Zoning
A
0
Z
County Zoning
Log Entries: 9
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
County Zoning
Original
A
1/31/2020
DSDESPINOZA
DSDESPINOZA
County Zoning
1281889
Electrical
Original
A
1/31/2020
SHELBY
SHELBY
Electrical
1281831
County Zoning
Original
D
1/17/2020
DSDESPINOZA
DSDESPINOZA
Addition Disapproved: Proposed placement does not meet minimum setback requirement of 25 FT for RR-5 Zoning District. Applicant can either move placement to meet minimum setback requirement, or request an administrative relief process with EPC PCD Planner-of-the-Day for placement as-is. (
see full review
)
County Zoning
1277301
Electrical
Original
D
1/8/2020
BEND
BEND
The optimizer spec sheet is not legible. Please provide an updated spec sheet.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.)
Electrical
1273680
Electrical
Original
D
12/30/2019
BEND
BEND
1. Missing one set of conductors between disconnect and array.
2. One line shows 29 modules but only 2 strings of 11.
3. Review DC disconnect vs. MPPT
4. Provide bus size for AC combiner.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.)
Electrical
1270839
Electrical
Original
D
12/27/2019
BEND
BEND
Need existing solar specs.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.)
Electrical
1270370
Out to Review
Original
/
12/27/2019
BEND
BEND
Out to Review
1270368
Construction
Original
N
12/27/2019
BEND
BEND
Ground mount not to exceed 7'.
Construction
1270367
Floodplain
Original
N
12/27/2019
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5207003029)
Floodplain
1270317