County Zoning | Original | A | 1/31/2020 | DSDESPINOZA | DSDESPINOZA | | | County Zoning | 1281889 | Electrical | Original | A | 1/31/2020 | SHELBY | SHELBY | | | Electrical | 1281831 | County Zoning | Original | D | 1/17/2020 | DSDESPINOZA | DSDESPINOZA | Addition Disapproved: Proposed placement does not meet minimum setback requirement of 25 FT for RR-5 Zoning District. Applicant can either move placement to meet minimum setback requirement, or request an administrative relief process with EPC PCD Planner-of-the-Day for placement as-is. (see full review) | | County Zoning | 1277301 | Electrical | Original | D | 1/8/2020 | BEND | BEND | The optimizer spec sheet is not legible. Please provide an updated spec sheet. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1273680 | Electrical | Original | D | 12/30/2019 | BEND | BEND | 1. Missing one set of conductors between disconnect and array. 2. One line shows 29 modules but only 2 strings of 11. 3. Review DC disconnect vs. MPPT 4. Provide bus size for AC combiner. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1270839 | Electrical | Original | D | 12/27/2019 | BEND | BEND | Need existing solar specs. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1270370 | Out to Review | Original | / | 12/27/2019 | BEND | BEND | | | Out to Review | 1270368 | Construction | Original | N | 12/27/2019 | BEND | BEND | Ground mount not to exceed 7'. | | Construction | 1270367 | Floodplain | Original | N | 12/27/2019 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5207003029) | | Floodplain | 1270317 |
|
| |
|