Construction | Splice 08/31/20 | A | 8/31/2020 | MICHAELA | MICHAELA | Increase area of structural floor. | | Construction | 1375785 |
Electronic Plan | Splice 08/31/20 | / | 8/31/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1375782 |
CO Springs Fire | Original | A | 4/30/2020 | CSFIRE | CSFIRE | Reference CSFD review report online for inspection information - allow up to an hour for the report to load: http://springsgov.com/units/fire/Prevent/PlansReview/FPS_WebFPS.asp | dwithee | CO Springs Fire | 1316377 |
CO Springs DRE | Original | A | 4/24/2020 | KSCHOTT | KSCHOTT | approval of nsfr, meets design standards, any grading must conform to approved GECP (see full review) | | CO Springs DRE | 1314039 |
Zoning/Planning | Original | / | 4/21/2020 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1312374 |
Construction | Original | A | 4/21/2020 | MICHAELA | MICHAELA | | | Construction | 1312336 |
Enumeration | Original | A | 4/21/2020 | BEND | BEND | | | Enumeration | 1312266 |
Resubmittal 2 | Original | / | 4/21/2020 | GITA | GITA | Resubmittal #2 | | Resubmittal 2 | 1312161 |
CO Springs Fire | Original | D | 4/16/2020 | CSFIRE | CSFIRE | Reference CSFD review report online for disapproval comments: http://springsgov.com/units/fire/Prevent/PlansReview/FPS_WebFPS.asp | dwithee | CO Springs Fire | 1310155 |
CO Springs DRE | Original | D | 4/15/2020 | KSCHOTT | KSCHOTT | 1. Revise Hillside Site Plan to address comments noted in email. Emailed to contact on file 2. Address comments from Swent to be emailed to Gary,once received. 3. Include approved geo hazard with building permit resubmittal
If you have any questions, please contact Kerri Schott at kerri.schott@coloradosprings.gov (see full review) | | CO Springs DRE | 1309917 |
Zoning/Planning | Original | / | 4/10/2020 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1308065 |
Mechanical | Original | A | 4/10/2020 | JUSTINC | JUSTINC | | | Mechanical | 1307957 |
Electronic Plan | Original | / | 4/10/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1307945 |
Construction | Original | D | 4/10/2020 | MICHAELA | MICHAELA | 5-1/4 x 11-7/8 LVL inadequate at garage Provide a wall bracing solution where prescriptive braced panels are not being provided. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1307928 |
Electronic Plan | Original | / | 4/10/2020 | MATTHEW | MATTHEW | In Current Review by MATTHEW | | Electronic Plan | 1307896 |
Enumeration | Original | A | 4/10/2020 | BEND | BEND | | | Enumeration | 1307729 |
Resubmittal 1 | Original | / | 4/9/2020 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1307598 |
Out to Review | Original | / | 3/6/2020 | GITA | GITA | By Gary 719-210-6177 | | Out to Review | 1294702 |
Fire | Original | / | 2/28/2020 | | KSCHOTT | Location = Fire by KSCHOTT | | Fire | 1291988 |
CO Springs DRE | Original | D | 2/28/2020 | KSCHOTT | KSCHOTT | 1. Please address comments noted on HS checklist, emailed to the contact on file 2. Submit the approved GECP with building permit resubmittal 3. Submit geo hazard to kerri schott for review. Eligible for geo hazard waiver if all 3 criteria are met (see full review) | | CO Springs DRE | 1291987 |
Zoning/Planning | Original | / | 2/27/2020 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1291642 |
Plan Coordinator | Original | / | 2/27/2020 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1291618 |
Mechanical | Original | D | 2/27/2020 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Pending approved floor plan from construction reviewer.
O.S.A is to be indicated on page 2 of HVAC equipment certificate O.S.A when installed MUST be indicated on manual D
NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1291617 |
Mechanical | Original | / | 2/27/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1291599 |
Mechanical | Original | / | 2/27/2020 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1291464 |
Plan Coordinator | Original | / | 2/27/2020 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1291371 |
Construction | Original | D | 2/27/2020 | MICHAELA | MICHAELA | Show future lower level walls as dashed lines - solid lines for work done under this plan Locate crawlspace access in structural floor Show crawlspace in section view and indicate conditioning Provide wall bracing solutions - see plan for locations Missing hangers on roof framing page 2 LVL at garage door insuficient Missing posts below B1GX Revise truss engineering for trusses with porch exposure No walk-through
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1291370 |
Construction | Original | / | 2/26/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1291092 |
Construction | Original | / | 2/21/2020 | | SCANNING | Location = Construction by SCANNING | | Construction | 1289075 |
Plan Coordinator | Original | / | 2/21/2020 | | BEND | Location = Plan Coordinator by BEND | | Plan Coordinator | 1289032 |
Enumeration | Original | A | 2/21/2020 | BEND | BEND | | | Enumeration | 1289030 |
Floodplain | Original | N | 2/18/2020 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6314418001) | | Floodplain | 1287213 |