Mechanical | Original | A | 9/22/2021 | TCRIPPEN | TCRIPPEN | Approved. | | Mechanical | 1566783 |
Construction | Original | A | 9/22/2021 | MICHAELA | MICHAELA | | | Construction | 1566646 |
Enumeration | Original | A | 9/22/2021 | AMY | AMY | | | Enumeration | 1566594 |
Electronic Plan | Original | / | 9/22/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1566590 |
Resubmittal 8 | Original | / | 9/22/2021 | RITA | RITA | Resubmittal #8 Resubmittal for current approval stamps only. | | Resubmittal 8 | 1566322 |
Construction | Original | A | 6/23/2020 | MICHAELA | MICHAELA | As corrected. | | Construction | 1340093 |
Resubmittal 7 | Original | / | 6/22/2020 | NICKH | NICKH | Resubmittal #7 | | Resubmittal 7 | 1339682 |
Construction | Original | D | 6/22/2020 | MICHAELA | MICHAELA | Locate truss A-1 on roof framing plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1339568 |
Resubmittal 6 | Original | / | 6/19/2020 | BECKYA | BECKYA | Resubmittal #6 | | Resubmittal 6 | 1339359 |
Construction | Original | D | 6/19/2020 | MICHAELA | MICHAELA | Indicate design loads on roof framing page Correct insulation values in section view. Locate truss A1 (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1339191 |
Electronic Plan | Original | / | 6/19/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1339176 |
Resubmittal 5 | Original | / | 6/19/2020 | BECKYA | BECKYA | Resubmittal #5 | | Resubmittal 5 | 1339135 |
County Zoning | Original | A | 6/15/2020 | DSDESPINOZA | DSDESPINOZA | Review for SFD site plan previously approved on 6/9/20 and BESQCP on 5/18/20. Entry on 6/3/20 for third Driveway Access Permit remains denied. Only two Driveway Access Permits are allowed. | | County Zoning | 1336423 |
County Zoning | Original | / | 6/15/2020 | DSDESPINOZA | DSDESPINOZA | Awaiting direction from Joe Meekin. Plan Set was already approved for SFD and BESQCP. Brad Walters denied request for 3rd Driveway Access Permit on 6/3/20. | | County Zoning | 1336265 |
Construction | Original | D | 6/10/2020 | MICHAELA | MICHAELA | Indicate design loads on roof framing page Correct insulation values in section view. Missing truss A-1 (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1334398 |
Electronic Plan | Original | / | 6/10/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1334369 |
Resubmittal 4 | Original | / | 6/10/2020 | BECKYA | BECKYA | Resubmittal #4 | | Resubmittal 4 | 1334283 |
County Zoning | Original | D | 6/9/2020 | DSDESPINOZA | DSDESPINOZA | Review Complete. See comments below for: Single Family Dwelling, BESQCP, Driveway, Driveway (see full review) | | County Zoning | 1333798 |
County Zoning | Original | / | 6/9/2020 | DSDESPINOZA | DSDESPINOZA | Single Family Dwelling Approved: 6/9/20 Approved new SFD with attached garage (384 SF), covered front porch (95 SF), covered rear patio (285 SF). Proposed future accessory shop bldg. (3,500 SF, 50x70) not included in current scope of work. (see full review) | | County Zoning | 1333797 |
County Zoning | Original | / | 6/9/2020 | DOTWALTERS | DOTWALTERS | Driveway Approved (see full review) | | County Zoning | 1333795 |
Construction | Original | D | 6/9/2020 | MICHAELA | MICHAELA | Indicate design loads on roof framing page. Revise load capacity of H2.5A to proper value Indicate uplift hardware required at trusses exceeding uplift value of H2.5A 535# Missing truss A-1 Label all hangers Correct insulation values on section view. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1333423 |
Electronic Plan | Original | / | 6/9/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1333339 |
Resubmittal 3 | Original | / | 6/8/2020 | BECKYA | BECKYA | Resubmittal #3 | | Resubmittal 3 | 1332693 |
Construction | Original | D | 6/4/2020 | MICHAELA | MICHAELA | Revise the drawings per the mark-up from the first review. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1331656 |
Electronic Plan | Original | / | 6/4/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1331647 |
Enumeration | Original | A | 6/4/2020 | AMY | AMY | | | Enumeration | 1331544 |
Electronic Plan | Original | / | 6/4/2020 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1331541 |
County Zoning | Original | D | 6/3/2020 | DSDESPINOZA | DSDESPINOZA | Review Complete. See comments below for: Single Family Dwelling, BESQCP, Driveway (see full review) | | County Zoning | 1331296 |
County Zoning | Original | / | 6/3/2020 | DOTWALTERS | DOTWALTERS | Driveway Disapproved: This parcel already has two driveway access permits on file with our office, three access permits are not allowed. (see full review) | | County Zoning | 1331295 |
Resubmittal 2 | Original | / | 6/3/2020 | BECKYA | BECKYA | Resubmittal #2 | | Resubmittal 2 | 1331013 |
County Zoning | Original | D | 5/26/2020 | DSDESPINOZA | DSDESPINOZA | Review Complete. See comments below for: Single Family Dwelling, BESQCP, Driveway (see full review) | | County Zoning | 1327169 |
County Zoning | Original | / | 5/26/2020 | DSDESPINOZA | DSDESPINOZA | Driveway Disapproved: Project disapproved based on Single Family Review. Wait for resubmittal. (see full review) | | County Zoning | 1327168 |
County Zoning | Original | / | 5/26/2020 | DSDESPINOZA | DSDESPINOZA | Single Family Dwelling Disapproved: 5/26/20 Disapproved. Legal Description, Schedule Tax Number are missing from site plan. Also Proposed Structural area measurements (80'X42.7') for new residence does match footprint (54'x66') in submitted architectural plan. Depiction of residential footprint should be a reasonable likeness to that shown on architectural layout (garage, covered front porch and covered rear patio are not shown). (see full review) | | County Zoning | 1327167 |
Mechanical | Original | A | 5/26/2020 | TCRIPPEN | TCRIPPEN | okay using boiler | | Mechanical | 1326891 |
Electronic Plan | Original | / | 5/26/2020 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1326881 |
Construction | Original | D | 5/26/2020 | MICHAELA | MICHAELA | Missing structural plans (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1326880 |
Electronic Plan | Original | / | 5/26/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1326864 |
Enumeration | Original | D | 5/22/2020 | AMY | AMY | There is some confusion with the 2 driveways-should your address be from Avenida Hermosa or Cale Pacifico? tax schedule number is not included with the site plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1326354 |
Electronic Plan | Original | / | 5/22/2020 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1326347 |
Resubmittal 1 | Original | / | 5/22/2020 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1326251 |
County Zoning | Original | D | 5/18/2020 | DSDESPINOZA | DSDESPINOZA | Review Complete. See comments below for: Single Family Dwelling, BESQCP (see full review) | | County Zoning | 1324047 |
County Zoning | Original | / | 5/18/2020 | DSDESPINOZA | DSDESPINOZA | Single Family Dwelling Disapproved: Disapproved new custom SFD with attached garage (384 SF), covered front porch (95 SF), covered rear patio (285 SF). Site plan is incomplete - must show all Right-Of-Ways, location of lot in relation to abutting streets, driveway access location(s), and east side yard setback measurement. Future accessory shop bldg. (3,500 SF, 50x70) not included in current scope of work. (see full review) | | County Zoning | 1324046 |
County Zoning | Original | / | 5/18/2020 | DSDESPINOZA | DSDESPINOZA | BESQCP Approved (see full review) | | County Zoning | 1324019 |
Zoning/Planning | Original | / | 5/15/2020 | DSDESPINOZA | DSDESPINOZA | In Current Review by DSDESPINOZA | | Zoning/Planning | 1323541 |
Mechanical | Original | D | 5/15/2020 | TCRIPPEN | TCRIPPEN | Missing whole house ventilation page still required (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1323507 |
Electronic Plan | Original | / | 5/15/2020 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1323502 |
Construction | Original | D | 5/15/2020 | MICHAELA | MICHAELA | Label girder trusses for # of plys and bottom chord material. The uplift listed on the truss engineering provided exceeds the capacity of the typical hardware indicated. Please verify that you are accepting this condition. Indicate codes being complied with Provide design loads. Indicate post/beam connection. Add overframing description. Indicate requirements for garage/dwelling separation. Indicate location of slab insulation. See plan (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1323487 |
Electronic Plan | Original | / | 5/15/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1323454 |
Enumeration | Original | D | 5/7/2020 | BEND | BEND | Please show location of driveway on the site plan.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1319121 |
Floodplain | Original | N | 5/5/2020 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5735000001) | | Floodplain | 1317800 |