Mechanical | Original | A | 8/13/2021 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 1547179 |
GMF Zoning | Original | A | 8/13/2021 | SAVANNAHT | SAVANNAHT | SFH addition approved by Planning Commission at June 9, 2020 public hearing. | | GMF Zoning | 1547168 |
Resubmittal 4 | Original | / | 8/13/2021 | SAVANNAHT | SAVANNAHT | Resubmittal #4 | | Resubmittal 4 | 1547167 |
GMF Zoning | Original | A | 8/12/2021 | MICHAELA | MICHAELA | MA for GMF | | GMF Zoning | 1546326 |
Mechanical | Original | D | 8/10/2021 | JUSTINC | JUSTINC | No mechanical uploaded for review.
MECHANICAL REVIEW INCOMPLETE
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1544882 |
Electronic Plan | Original | / | 8/10/2021 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1544872 |
Construction | Original | A | 8/10/2021 | MICHAELA | MICHAELA | | | Construction | 1544772 |
Electronic Plan | Original | / | 8/10/2021 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1544602 |
Resubmittal 3 | Original | / | 8/10/2021 | MICHAELA | MICHAELA | Resubmittal #3 Michael | | Resubmittal 3 | 1544600 |
GMF Zoning | Original | A | 4/12/2021 | GMFPLANNER | GMFPLANNER | SFH addition approved by Planning Commission at June 9, 2020 public hearing. | Julia Simmons | GMF Zoning | 1483634 |
Mechanical | Original | D | 3/24/2021 | JUSTINC | JUSTINC | losses shown are 10,127. this does not meet or exceed? When 2nd level is added losses will be even greater? How will the 2nd level be heated? Calculations dont show 2nd level?
MECHANICAL REVIEW INCOMPLETE
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1474879 |
Construction | Original | D | 3/24/2021 | MICHAELA | MICHAELA | Missing foundation plan Missing floor beam sizes Missing posts below beams. Locate smoke and CO detectors. Provide truss engineering and label roof layout. H2.5 hanger is not acceptable. Indicate a different hanger. If you are venting the crawlspace include the size of the vents, Show insulation in the floor and not on the crawlspace walls. Specify hangers at crawlspace access. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1474552 |
Resubmittal 2 | Original | / | 3/23/2021 | ANDREAL | ANDREAL | Resubmittal #2 | | Resubmittal 2 | 1474003 |
Plan Coordinator | Original | D | 11/9/2020 | JAY | JAY | Disapprove all remaining departments to allow plan to be resubmitted | | Plan Coordinator | 1410050 |
Mechanical | Original | D | 10/23/2020 | JUSTINC | JUSTINC | Pending approved floor plan from construction reviewer (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1402980 |
Construction | Original | D | 10/23/2020 | MICHAELA | MICHAELA | IECC indicates floor insulation and so a vented crawlspace. Size and locate vents. Locate attic access. Locate crawlspace access. Dimension deck. Locate attic access. Locate crawlspace access. Stamped truss engineering must be provided at the time of plan review. Indicate roof pitch. H2.5 anchors were discontinued years ago. Provide a hanger that has a current listed value. HHUS hangers are totally unnecessary. Use LU 28 hangers. Size the deck beam. Indicate joist size and o.c. spacing at deck Provide upper story height. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1402969 |
Resubmittal 1 | Original | / | 10/22/2020 | JAY | JAY | Resubmittal #1 | | Resubmittal 1 | 1402227 |
Mechanical | Original | D | 10/5/2020 | JUSTINC | JUSTINC | Pending approved floor plan from construction reviewer (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1393876 |
Electronic Plan | Original | / | 10/5/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1393505 |
Construction | Original | D | 10/5/2020 | MICHAELA | MICHAELA | This storage space meets the definition of a story. It must have a compliant means of egress and cannot employ a ships ladder for that purpose. The center section of the roof uses the ridge board as a beam. 2x6 is very inadequate. Size beam and indicate posts and support at each end. Address uplift resistance.Address rafter connection to ridge beam. 2x8 floor joists are inadequate at the loft framing (2) 1-3/4" x 11-7/8" LVL floor beam is inadequate. IECC form shows floor insulation, not insulation at the crawlspace wall. Correct the form or revise the elevation drawing. Locate crawlspace access. Locate attic access. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1393501 |
Electronic Plan | Original | / | 10/5/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1393445 |
Zoning/Planning | Original | / | 10/2/2020 | SYSTEM | SYSTEM | You will need to contact Zoning/Planning department for approval prior to permit. This department will not review the plan electronically. | | Zoning/Planning | 1392788 |
Floodplain | Original | N | 10/2/2020 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 8308307047) | | Floodplain | 1392787 |