13010 CRUMP RD, COLORADO SPRINGS, CO 80908
Permit #
N16251
Parcel Info
6212000082
Truss P/SF
40 (Elevation: 7,320 Feet)
Project
DETACHED GARAGE (
436
)
Type Of Plan
Normal
Review Type
Electronic
Fire District
BLACK FOREST FIRE PROTECTION DISTRICT
Submit Date
Approval Date
Location
Resubmittal
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 3
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Construction
A
0
C
Construction
Floodplain
N
W
Floodplain
County Zoning
A
Z
County Zoning
Log Entries: 9
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
Construction
Original
A
10/23/2020
CGIECK
CGIECK
Construction
1402821
Electronic Plan
Original
/
10/23/2020
CGIECK
CGIECK
In Current Review by CGIECK
Electronic Plan
1402751
Resubmittal 1
Original
/
10/22/2020
BECKYA
BECKYA
Resubmittal #1
Resubmittal 1
1402666
County Zoning
Original
A
10/16/2020
DSDRANGEL
DSDRANGEL
Addition Approved (
see full review
)
County Zoning
1399847
Zoning/Planning
Original
/
10/16/2020
DSDRANGEL
DSDRANGEL
In Current Review by DSDRANGEL
Zoning/Planning
1399811
Construction
Original
D
10/16/2020
CGIECK
CGIECK
Wind speed should be 130 mph as required.
Bottom chord load does not appear to match truss design.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.)
Construction
1399800
Construction
Original
D
10/16/2020
BPHILLIPS
BPHILLIPS
Revise climatic design criteria. 130 mph Vult is minimum wind speed design. Dead load design on trusses is 10 psf. Plans and trusses must match.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.)
Construction
1399783
Electronic Plan
Original
/
10/16/2020
CGIECK
CGIECK
In Current Review by CGIECK
Electronic Plan
1399742
Floodplain
Original
N
10/15/2020
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6212000082)
Floodplain
1399135