CO Springs DRE | Original | A | 7/15/2021 | KSCHOTT | KSCHOTT | approval of attached addition 621 sf; meets design standards, lot coverage at 17%; height not to exceed 35' from existing grade (see full review) | | CO Springs DRE | 1531142 |
Stormwater | Original | A | 7/15/2021 | JMOXNESS | JMOXNESS | | | Stormwater | 1530922 |
Mechanical | Original | A | 7/13/2021 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 1529948 |
Zoning/Planning | Original | / | 7/13/2021 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1529944 |
Construction | Original | A | 7/13/2021 | SHELLEY | SHELLEY | Conditioned crawlspace. See plans. | | Construction | 1529885 |
Resubmittal 3 | Original | / | 7/13/2021 | SHELLEY | SHELLEY | Resubmittal #3 | | Resubmittal 3 | 1529838 |
CO Springs DRE | Original | D | 7/9/2021 | KSCHOTT | KSCHOTT | 1. Include hillside certification statement on site plan (sign/date it) 2. Site plan should have a PE stamp 3. Show limit of disturbance boundary (10-15' perimeter around proposed structure) and show stockpile location within limit of disturbance 4. Show utility lines (water, sewer, gas) 5. Show new TOTAL lot coverage in legend (include first floor area sf + garage sf + covered decks/porches sf + new addition sf / total lot size) 6. Show distance from proposed structure to front AND side property line 7. Show drainage patterns with arrows and finished/proposed grade lines 8. Show vegetation that will be affected, if any or note if no vegetation to be removed 9. Elevations: Show height to peak from existing grade line on each drawing (not to exceed 35' from existing grade) kerri.schott@coloradosprings.gov (see full review) | | CO Springs DRE | 1528120 |
Stormwater | Original | D | 7/7/2021 | JMOXNESS | JMOXNESS | - Show limits of disturbance. - Show soils stockpile within limits of disturbance. - Show existing and proposed topography and add to legend. - Show flow arrows. | | Stormwater | 1527048 |
Construction | Original | D | 7/7/2021 | SHELLEY | SHELLEY | After review by mechanical, there is a discrepency with the crawlspace conditioning. Plan shows crawlspace vents, which require floor insulation. If crawlspace is to be conditioned, remove crawlspace vent notes and floor insulation from IECC. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1526980 |
Mechanical | Original | D | 7/7/2021 | TCRIPPEN | TCRIPPEN | The A -pages are showing vented crawl space, calculations is showing conditioned crawl space one or the other needs to be revised, (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1526575 |
Zoning/Planning | Original | / | 7/6/2021 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1526106 |
Construction | Original | A | 7/6/2021 | SHELLEY | SHELLEY | AS NOTED - please review plans prior to construction
NOTE: Finished grade in crawlspace is to be such that the average height of the entire crawlspace is less than 5'. If average height does not meet this requirement, a splice to create a basement is required and all basement level requirements must be met | | Construction | 1526094 |
Resubmittal 2 | Original | / | 7/6/2021 | SHELLEY | SHELLEY | Resubmittal #2 | | Resubmittal 2 | 1526093 |
CO Springs DRE | Original | D | 6/9/2021 | KSCHOTT | KSCHOTT | 1. Revise Hillside Site Plan to address comments noted on the checklist, emailed to contact on file
If you have any questions, please contact Kerri Schott at kerri.schott@coloradosprings.gov (see full review) | | CO Springs DRE | 1514085 |
Stormwater | Original | D | 6/2/2021 | JMOXNESS | JMOXNESS | - Show limits of disturbance. - Show soils stockpile within limits of disturbance. - Show existing and proposed topography. - Show flow arrows. | | Stormwater | 1509700 |
Zoning/Planning | Original | / | 6/1/2021 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1509176 |
Mechanical | Original | D | 6/1/2021 | TCRIPPEN | TCRIPPEN | See Construction notes (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1509027 |
Electronic Plan | Original | / | 6/1/2021 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1509003 |
Construction | Original | D | 6/1/2021 | SHELLEY | SHELLEY | Reconcile IECC with plans; Crawlspaces are limited to 5' average height. This does not qualify as a crawlspace. This is a basement. Provide basement floor plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1508811 |
Resubmittal 1 | Original | / | 6/1/2021 | SAVANNAHT | SAVANNAHT | Resubmittal #1 | | Resubmittal 1 | 1508796 |
Stormwater | Original | D | 4/8/2021 | JMOXNESS | JMOXNESS | - Show existing and proposed contours. - Show area of disturbance. - Show Soils Stockpile area within area of disturbance. - Show flow arrows. | | Stormwater | 1482072 |
CO Springs DRE | Original | D | 4/6/2021 | KSCHOTT | KSCHOTT | This lot is within the hillside overlay; insufficient hillside site plan. Emailed contact on file hillside site plan checklist and what is required for site plan stamped by PE and hillside elevations. If addition is < 50% of existing footprint, geohazard ordinance is not triggered kerri.schott@coloradosprings.gov (see full review) | | CO Springs DRE | 1481003 |
Zoning/Planning | Original | / | 4/1/2021 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 1479379 |
Mechanical | Original | D | 3/31/2021 | TCRIPPEN | TCRIPPEN | I need an approved IECC, Calculations are showing crawl space? (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1478614 |
Electronic Plan | Original | / | 3/31/2021 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1478583 |
Construction | Original | D | 3/31/2021 | SHELLEY | SHELLEY | Reconcile IECC with plans, plans indicate a basement, not a crawlspace; provide basement floor plan; see plans. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1478536 |
Electronic Plan | Original | / | 3/31/2021 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 1478531 |
Stormwater | Original | / | 3/26/2021 | SYSTEM | SYSTEM | Parcel 6506308002 is within the Hillside Overlay (HS). Stormwater Review is required. | | Stormwater | 1476198 |
Floodplain | Original | N | 3/26/2021 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6506308002) | | Floodplain | 1476199 |