County Zoning | Original | D | 7/26/2023 | DSDARCHULETA | DSDARCHULETA | DISAPPROVED: REFERENCE PS-2355 PROJECT SCOPING SECOND HOUSE NOT ALLOWED. IF THE INTENT IS AS AN ACCESSORY LIVING QUARTERS, THE PROPOSED SECOND HOUSE EXCEEDS THE ALQ MAX OF 1,500sf (LESS THE POOL, THE PROPOSED HOUSE LOWER LEVEL APPROX. 2,400sf, UPPER LEVEL APPROX 3,000sf ). | | County Zoning | 1875789 |
Zoning/Planning | Original | / | 7/21/2023 | DSDARCHULETA | DSDARCHULETA | In Current Review by DSDARCHULETA | | Zoning/Planning | 1873796 |
Zoning/Planning | Original | / | 7/21/2023 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1873760 |
Plan Coordinator (Main) | Original | / | 7/21/2023 | | TCRIPPEN | Location = Plan Coordinator (Main) by TCRIPPEN | | Plan Coordinator (Main) | 1873744 |
Mechanical | Original | D | 7/21/2023 | TCRIPPEN | TCRIPPEN | Disapproved: Need cfm for kitchen hood , provide equipment certificate and whole house ventilation and to be stamped by engineer, is furnace rated for pool room, do you dehumidification for indoors pool. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 1873725 |
Mechanical (Main) | Original | / | 7/20/2023 | | SCANNING | Location = Mechanical (Main) by SCANNING | | Mechanical (Main) | 1873267 |
Plan Coordinator (Main) | Original | / | 7/20/2023 | | JUSTINL | Location = Plan Coordinator (Main) by JUSTINL | | Plan Coordinator (Main) | 1873253 |
Construction | Original | D | 7/20/2023 | JUSTINL | JUSTINL | Affidavit may be required for 2nd dwelling unit. Roof trusses not designed for tile roof. Clarify if pool room will be part of building thermal envelope. Does not appear to meet glazing requirements for sun room. Does not meet requirements for patio enclosure due to electric heat. If pool room is part of thermal envelope, verify that walls and glazing meet prescriptive IECC values. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 1873252 |
Construction (Main) | Original | / | 7/20/2023 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Construction (Main) | 1873194 |
Construction (Main) | Original | / | 7/3/2023 | | SCANNING | Location = Construction (Main) by SCANNING | | Construction (Main) | 1866057 |
Plan Coordinator (Main) | Original | / | 7/3/2023 | | BECKYA | Location = Plan Coordinator (Main) by BECKYA | | Plan Coordinator (Main) | 1866054 |
Enumeration | Original | A | 7/3/2023 | BECKYA | BECKYA | | | Enumeration | 1866053 |
Enumeration (Main) | Original | / | 7/3/2023 | BECKYA | BECKYA | In Current Review by BECKYA | | Enumeration (Main) | 1866041 |
Enumeration (Main) | Original | / | 6/29/2023 | | JACKIEP | Location = Enumeration (Main) by JACKIEP | | Enumeration (Main) | 1864717 |
Floodplain | Original | N | 6/28/2023 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7136002004) | | Floodplain | 1863843 |