Plan #
  
Type
 
Plan
Owner
Address
8262 AIRPARK HTS, PEYTON, CO 80831
Parcel Info
4304001135
Truss P/SF
30 (Elevation: 6,849 Feet)
Bedrooms
5
Project
RESIDENCE (
101
)
Type Of Plan
Normal
Review Type
Electronic
Fire District
FALCON FIRE PROTECTION DISTRICT
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 9
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Construction
D
0
C
Construction
Electrical
D
0
E
Electrical
Energy
/
G
Energy
Enumeration
A
0
N
Enumeration
Falcon Fire (CSFD)
/
F
Falcon Fire (CSFD)
Floodplain
N
W
Floodplain
Mechanical
/
M
Mechanical
Plumbing
D
0
P
Plumbing
County Zoning
D
0
Z
County Zoning
Log Entries: 12
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
County Zoning
Original
D
9/28/2026
DSDYOUNGER
DSDYOUNGER
1.) As of May 4, 2026, all applicants are required to submit a Stormwater Permit Request Form to initiate an application for new single-family residential construction. The form is available on the EPC website at: www.epc-stormwaterpermit.com/
Please note that an approved Stormwater Permit must be obtained prior to the issuance of a Building Permit through Pikes Peak Regional Building Department (PPRBD).
At this time, your plan cannot be reviewed. Once the Stormwater Permit Request Form has been submitted and the appropriate permit has been obtained, YOU MUST UPLOAD your approved, stamped Stormwater Permit Form with the resubmittal for review. For any questions contact the Stormwater department at StormWater@elpasoco.com.
2.) Site plan must include all easements on the property the recorded from plat. See site plan for screengrab of plat.
County Zoning
2364080
Zoning/Planning
Original
/
9/28/2026
DSDYOUNGER
DSDYOUNGER
In Current Review by DSDYOUNGER
Zoning/Planning
2364009
Plumbing
Original
D
9/28/2026
SHANEN
SHANEN
Provide a bonus room plumbing plan. Show minimum water closet clearances. Provide shower pan dimensions. Show air barriers for all tubs and/or showers located on an outside wall.
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Plumbing
2363996
Electrical
Original
D
9/28/2026
CONNERM
CONNERM
AMM required to submit under 2024 IECC
Show location of emergency disconnect
Specify and show potential PV pathway from attic to electric panel. If vertical pathway then specify so
Show locations of conduit and termination points serving the EV ready space.
Show an EV ready space noted in the garage
Provide a plan note stating a minimum 2-pole, 40 amp GFCI breaker, conduit, conductor, and receptacle is provided for an EV Charger
Provide a plan note stating there will be a 2-pole breaker space for each proposed combustion appliance
Provide plan note stating there will be a 2-pole breaker space at the opposite end of the buss for Solar Ready.
Provide a plan note stating compliance with 2021 IECC R402.4.6 limiting air leakage through electrical and communication outlet boxes installed in the building thermal envelope
Show compliance with IECC R404.2 and R404.3
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Electrical
2363994
Electronic Plan
Original
/
9/28/2026
CONNERM
CONNERM
In Current Review by CONNERM
Electronic Plan
2363987
Construction
Original
D
9/28/2026
JUSTINL
JUSTINL
Preliminary review only.
See architectural plans and IECC document for review comments.
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Construction
2363964
Electronic Plan
Original
/
9/25/2026
JUSTINL
JUSTINL
In Current Review by JUSTINL
Electronic Plan
2363904
Enumeration
Original
A
9/21/2026
AMY
AMY
The legal description is required to be on the site plan. Refer to the Enumerations Requirement handout. This information was added for you.
Enumeration
2361397
Electronic Plan
Original
/
9/21/2026
AMY
AMY
In Current Review by AMY
Electronic Plan
2361385
Original
/
9/18/2026
SYSTEM
SYSTEM
Plan Review fees paid 09/18/2026 for plan submitted 09/18/2026. Submit Date updated to now. Plan now open for review.
2361300
Energy
Original
/
9/18/2026
SYSTEM
SYSTEM
Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews
Energy
2361292
Floodplain
Original
N
9/18/2026
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 4304001135)
Floodplain