| CO Springs Fire | Original | D | 10/28/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | nickbrown | CO Springs Fire | 2376141 |
| CO Springs DRE | Original | D | 10/27/2026 | SSADLER | SSADLER | Upload the pre application summary that was provided. Upload the approval letter and the approved stamped plans for the administrative adjustment (ADRF-26-0052). Provide a recorded deed dated prior to February 1951 to show lot of record. | | CO Springs DRE | 2375642 |
| Energy | Original | D | 10/26/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2374960 |
| Mechanical | Original | D | 10/26/2026 | QUINTONW | QUINTONW | Disapproved see equipment cert and heat calcs for all disapproval comments * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2374959 |
| Plumbing | Original | A | 10/23/2026 | SHANEN | SHANEN | | | Plumbing | 2374454 |
| City Engr | Original | D | 10/23/2026 | HVO | HVO | EDRD has determined geological hazards exist in this area and requires a Geologic Hazard Report. Please submit it to EDRD through our electronic review system called ProjectDox. Below is a link to ProjectDox and a user manual. https://coloradosprings.gov/stormwater/planreview
Once it has been approved please upload the approved file with building submission. | | City Engr | 2374426 |
| Zoning/Planning | Original | / | 10/23/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2374423 |
| Floodplain | Original | D | 10/23/2026 | KEITH | KEITH | The proposed addition is located within the Cheyenne Creek floodway. A "No-Rise" certification and supporting technical report are required. This report must be prepared and stamped by a registered Colorado Professional Engineer (PE) to demonstrate that the development will cause zero increase (0.00 feet) to the established floodway elevations. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Floodplain | 2374332 |
| Electrical | Original | D | 10/22/2026 | CONNERM | CONNERM | Show locations of conduit and termination points serving the EV ready space.
Show an EV ready space noted in the garage
Provide a plan note stating a minimum 2-pole, 40 amp GFCI breaker, conduit, conductor, and receptacle is provided for an EV Charger
Provide a plan note stating compliance with 2021 IECC R402.4.6 limiting air leakage through electrical and communication outlet boxes installed in the building thermal envelope
Show compliance with IECC R404.2 and R404.3 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2374229 |
| Construction | Original | D | 10/22/2026 | DOUGC | DOUGC | Preliminary review ONLY. IECC was submitted under the 2024 code cycle, disapprove to allow for resubmittal. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2374207 |
| | Original | / | 10/22/2026 | SYSTEM | SYSTEM | Plan Review fees paid 10/22/2026 for plan submitted 10/22/2026. Submit Date updated to now. Plan now open for review. | | | 2374204 |
| Energy | Original | / | 10/22/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2373918 |
| Fire | Original | / | 10/22/2026 | RBD GIS | RBD GIS | Parcel 7425121035 is within the Wildland Urban Interface (WUI). Fire Department Review is required. | | Fire | 2373916 |
| Floodplain | Original | / | 10/22/2026 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 7425121035) | | Floodplain | 2373917 |