Mechanical | Splice 3/10/14 | A | 3/11/2014 | DALEH | DALEH | | | Mechanical | 692672 |
Out to Review | Splice 3/10/14 | / | 3/11/2014 | DANM | DANM | Added dormer and swapped bath and stairs | | Out to Review | 692634 |
Construction | Splice 3/10/14 | A | 3/11/2014 | DANM | DANM | | | Construction | 692633 |
Construction | Splice 3/10/14 | D | 3/10/2014 | SHELLEY | SHELLEY | provide new trusses and make changes to both sets. | | Construction | 692296 |
Black Forest Fire | Original | A | 10/10/2013 | JANE | JANE | | | Black Forest Fire | 663687 |
Out to Review | Original | / | 10/8/2013 | NELIDA | NELIDA | Dan 499-6888 | | Out to Review | 662935 |
Finished Bin | Original | / | 10/8/2013 | | BPHILLIPS | Location = Finished Bin by BPHILLIPS | | Finished Bin | 662918 |
Plan Coordinator | Original | / | 10/8/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 662913 |
Construction | Original | A | 10/8/2013 | DANM | DANM | | | Construction | 662912 |
Construction | Original | / | 10/7/2013 | DANM | DANM | In Current Review by DANM | | Construction | 662836 |
Construction | Original | / | 10/7/2013 | MICHAELA | MICHAELA | In Current Review by MICHAEL | | Construction | 662824 |
Construction | Original | / | 10/7/2013 | | JANE | Location = Construction by JANE | | Construction | 662703 |
Resubmittal 4 | Original | / | 10/7/2013 | JANE | JANE | Resubmittal #4 | | Resubmittal 4 | 662702 |
Out to Review | Original | / | 10/4/2013 | REBECCA | REBECCA | dan 499-6888 | | Out to Review | 662571 |
Finished Bin | Original | / | 10/4/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 662542 |
Plan Coordinator | Original | / | 10/4/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 662531 |
Construction | Original | D | 10/4/2013 | DANM | DANM | See plans for 'redlines' to revised roof framing plan - mostly some connections do not meet uplift requirements No Walk | | Construction | 662530 |
Construction | Original | / | 10/4/2013 | DANM | DANM | In Current Review by DANM | | Construction | 662377 |
Construction | Original | / | 10/3/2013 | | NELIDA | Location = Construction by NELIDA | | Construction | 662178 |
Resubmittal 3 | Original | / | 10/3/2013 | NELIDA | NELIDA | Resubmittal #3 10/3/13 | | Resubmittal 3 | 662176 |
Out to Review | Original | / | 10/1/2013 | NELIDA | NELIDA | Dan 499-6888 | | Out to Review | 661272 |
Finished Bin | Original | / | 10/1/2013 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 661116 |
Plan Coordinator | Original | / | 9/30/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 661090 |
Construction | Original | D | 9/30/2013 | DANM | DANM | Roof framing plan - RBD comments do not appear to be addressed from previous submittal See plans No Walk | | Construction | 661089 |
Construction | Original | / | 9/30/2013 | DANM | DANM | In Current Review by DANM | | Construction | 660997 |
Construction | Original | / | 9/30/2013 | | JANE | Location = Construction by JANE | | Construction | 660878 |
Resubmittal 2 | Original | / | 9/30/2013 | JANE | JANE | Resubmittal #2 | | Resubmittal 2 | 660877 |
Out to Review | Original | / | 9/19/2013 | JANE | JANE | Dan Gillis | | Out to Review | 659071 |
Finished Bin | Original | / | 9/19/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 659035 |
Plan Coordinator | Original | / | 9/19/2013 | | MICHAELA | Location = Plan Coordinator by MICHAEL | | Plan Coordinator | 659033 |
Construction | Original | D | 9/19/2013 | MICHAELA | MICHAELA | Revise three trusses for porch exposure - review uplift when new engineering is provided Missing detail A-A uplift insufficient many locations No walk-through | | Construction | 659032 |
Construction | Original | / | 9/19/2013 | MICHAELA | MICHAELA | In Current Review by MICHAEL | | Construction | 658996 |
Construction | Original | / | 9/19/2013 | | JANE | Location = Construction by JANE | | Construction | 658947 |
Resubmittal 1 | Original | / | 9/19/2013 | JANE | JANE | Resubmittal #1 | | Resubmittal 1 | 658946 |
Mechanical | Original | A | 9/19/2013 | DALEH | DALEH | | | Mechanical | 658942 |
Health Dept. | Original | A | 9/19/2013 | HEALTHDEPT | HEALTHDEPT | ON0033110; OWTS permit on file for 5 bdrm home, a 5 bdrm home is proposed; APPROVED, CJC | Chuck Cousino | Health Dept. | 658844 |
County Zoning | Original | A | 9/18/2013 | DSDSPAULDING | DSDSPAULDING | | | County Zoning | 658726 |
Out to Review | Original | / | 9/17/2013 | NELIDA | NELIDA | Dan 499-6888 | | Out to Review | 658371 |
Finished Bin | Original | / | 9/17/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 658213 |
Plan Coordinator | Original | / | 9/17/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 658189 |
Mechanical | Original | D | 9/17/2013 | RUSSELL | RUSSELL | Per the architectural sheets, missing exhaust fans on both levels, missing louvered door, hi/low grilles or all combustion air from the exterior on the basement levle, missing the vent up location on the basement level, missing the vnet up on the main level, missing the 100 square inch free area makeup air opening into the laundry room, duct design missing the extension of the ductwork and the duct up in one location, heat loss calculations and equipment cert. ok | | Mechanical | 658188 |
Mechanical | Original | / | 9/17/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 658181 |
Mechanical | Original | / | 9/16/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 657979 |
Plan Coordinator | Original | / | 9/16/2013 | | MICHAELA | Location = Plan Coordinator by MICHAEL | | Plan Coordinator | 657966 |
Construction | Original | D | 9/16/2013 | MICHAELA | MICHAELA | Add note for required garage/house separation Note: Without specific zoning approval there can only be one cooktop in a single family dwelling Provide details for typical exterior wall framing Locate and size posts below on floor framing page Detail A-A requires an engineer's stamp Label all girder trusses for number of plys and bottom chord composition Label all hangers Locate and size all posts Provide additional uplift resistant hardware where uplift exceeds 365# Provide method of wall bracing being used per IRC 602.10 Note: Foundation design provided does not reference a soils report and does not indicate allowable bearing. This report would be insufficient for construction approval No walk-through | | Construction | 657965 |
Construction | Original | / | 9/13/2013 | MICHAELA | MICHAELA | In Current Review by MICHAEL | | Construction | 657907 |
Construction | Original | / | 9/13/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 657890 |
Plan Coordinator | Original | / | 9/13/2013 | | JEANNINE | Location = Plan Coordinator by JEANNINE | | Plan Coordinator | 657807 |
Enumeration | Original | A | 9/13/2013 | JEANNINE | JEANNINE | | | Enumeration | 657806 |
Out to Review | Original | / | 9/12/2013 | REBECCA | REBECCA | walking | | Out to Review | 657603 |
Floodplain | Original | N | 9/12/2013 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 657599 |