To Be Scanned Bin | Original | / | 10/1/2013 | | JANE | Location = To Be Scanned Bin by JANE | | To Be Scanned Bin | 661269 |
Black Forest Fire | Original | A | 10/1/2013 | JANE | JANE | | | Black Forest Fire | 661268 |
Out to Review | Original | / | 9/25/2013 | REBECCA | REBECCA | susan 499-4467 | | Out to Review | 660059 |
Finished Bin | Original | / | 9/24/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 659901 |
Plan Coordinator | Original | / | 9/24/2013 | | JOHNW | Location = Plan Coordinator by JOHNW | | Plan Coordinator | 659876 |
Elevators | Original | A | 9/24/2013 | JOHNW | JOHNW | ELEVATOR COMPLETE | | Elevators | 659875 |
Elevators | Original | / | 9/24/2013 | | BPHILLIPS | Location = Elevators by BPHILLIPS | | Elevators | 659805 |
County Zoning | Original | A | 9/24/2013 | DSDSPAULDING | DSDSPAULDING | FEE WAS PAID WITH BARN APPROVAL RECEIPT B56253 | | County Zoning | 659795 |
Construction | Original | A | 9/24/2013 | JIMA | JIMA | | | Construction | 659783 |
Mechanical | Original | A | 9/24/2013 | RUSSELL | RUSSELL | | | Mechanical | 659777 |
Out to Review | Original | / | 9/24/2013 | REBECCA | REBECCA | gary 499-4320 | | Out to Review | 659723 |
Finished Bin | Original | / | 9/20/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 659160 |
Plan Coordinator | Original | / | 9/20/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 659155 |
Mechanical | Original | D | 9/20/2013 | RUSSELL | RUSSELL | Need to coordinate mechanical with the architectural sheets, is it conditioned or unconditioned crawl space, coordinate, which effects heat loss calculations and duct insulation loss, see duct design for other comments and comments on heat loss calculations and the HVAC equipment certificate, venting on architectural sheets is incorrect, cannot vent high efficiency furnaces with the water heaters, need separate vents for the furnaces, add O.A./fresh air ducts to plans and when for fresh air, need to be dampered per IECC requirements, no walk | | Mechanical | 659154 |
Mechanical | Original | / | 9/20/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 659125 |
Mechanical | Original | / | 9/20/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 659114 |
Plan Coordinator | Original | / | 9/20/2013 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 659106 |
Construction | Original | D | 9/20/2013 | SHELLEY | SHELLEY | Cannot locate pb5 truss; additional uplift needed on two trusses; see plans; walk ok. | | Construction | 659105 |
Health Dept. | Original | A | 9/20/2013 | HEALTHDEPT | HEALTHDEPT | ON0020922; Eval received; Prop 4 bdrm; Exist. permit for 4 bdrm; Approved; CJC | Chuck Cousino | Health Dept. | 659100 |
Construction | Original | / | 9/18/2013 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 658679 |
Construction | Original | / | 9/18/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 658604 |
Plan Coordinator | Original | / | 9/18/2013 | | JEANNINE | Location = Plan Coordinator by JEANNINE | | Plan Coordinator | 658600 |
Enumeration | Original | A | 9/18/2013 | JEANNINE | JEANNINE | Approval for residence on property; not barn (requires separate permit) | | Enumeration | 658599 |
Enumeration | Original | / | 9/17/2013 | | NELIDA | Location = Enumeration by NELIDA | | Enumeration | 658466 |
Out to Review | Original | / | 9/17/2013 | NELIDA | NELIDA | Gary 491-3249 | | Out to Review | 658460 |
Floodplain | Original | N | 9/17/2013 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 658459 |