Health Dept. | Original | A | 10/18/2013 | HEALTHDEPT | HEALTHDEPT | ON0020449; EPCPH permit issued for a 5 bedroom home, 10/18/2013; CJC | Chuck Cousino | Health Dept. | 665459 |
Black Forest Fire | Original | A | 10/10/2013 | REBECCA | REBECCA | BFFR 10-10-13 | | Black Forest Fire | 663705 |
Mechanical | Original | A | 10/10/2013 | DALEH | DALEH | | | Mechanical | 663697 |
Out to Review | Original | / | 10/10/2013 | SHELLEY | SHELLEY | | | Out to Review | 663653 |
Construction | Original | A | 10/10/2013 | SHELLEY | SHELLEY | | | Construction | 663652 |
Health Dept. | Original | / | 10/8/2013 | | KENYATTA | Location = Health Dept. by KENYATTA | | Health Dept. | 663073 |
Plan Coordinator | Original | / | 10/8/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 663060 |
Mechanical | Original | D | 10/8/2013 | RUSSELL | RUSSELL | Heat loss calculations & equipment cert, are okay, duct design sheets need to be mirrored, to match architectural floor plans, plans are not site specific | | Mechanical | 663059 |
Mechanical | Original | / | 10/8/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 663048 |
Mechanical | Original | / | 10/7/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 662651 |
Plan Coordinator | Original | / | 10/7/2013 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 662636 |
Construction | Original | D | 10/7/2013 | JIMA | JIMA | see sheets a-2 and s-2 for corrections it's ok to write in changes on green marked up set of plans label each girder truss on plans as requested on first review IE: bottom cord size and type of material e.f. in master bath still required without operable window also window in shower needs tempered ( original plans shows you made a change to this window but its not on the new page ?? ) call out post under steel beams in wood framed walls call out all post with connections at top and bottom for deck and porch insert new pages into plans with the original site plan page and back page remove old pages | | Construction | 662635 |
Construction | Original | / | 10/7/2013 | JIMA | JIMA | In Current Review by JIMA | | Construction | 662595 |
Construction | Original | / | 10/4/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 662532 |
Resubmittal 1 | Original | / | 10/4/2013 | REBECCA | REBECCA | Resubmittal #1 | | Resubmittal 1 | 662391 |
County Zoning | Original | A | 10/2/2013 | DSDSPAULDING | DSDSPAULDING | | | County Zoning | 661815 |
Out to Review | Original | / | 10/2/2013 | MINDY | MINDY | Kyle 648 5256 | | Out to Review | 661788 |
Health Dept. | Original | / | 10/2/2013 | | KENYATTA | Location = Health Dept. by KENYATTA | | Health Dept. | 661486 |
Plan Coordinator | Original | / | 10/2/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 661458 |
Mechanical | Original | D | 10/2/2013 | RUSSELL | RUSSELL | Provide duct design on a full size sheet (24" x 36"), master bath missing an exhaust fan, mech room missing combustion air, fully louvered door, hi/low grilles or c.a. duct from the exterior, IECC indicates insulation of basement walls to be R-15, not R-13, also IECC indicates windows and doors at .35, not at ,28 or nothing, redo HVAC Equipment Certificate after R values changed, furnace efficiency of 92.1% changes the output btuh's on the HVAC Equipment Certificate, | | Mechanical | 661456 |
Mechanical | Original | / | 10/2/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 661446 |
Mechanical | Original | / | 9/30/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 661019 |
Plan Coordinator | Original | / | 9/30/2013 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 661011 |
Construction | Original | D | 9/30/2013 | JIMA | JIMA | see plans : review stopped // no walk resubmit with changes that have been marked - for full review | | Construction | 661010 |
Construction | Original | / | 9/30/2013 | JIMA | JIMA | In Current Review by JIMA | | Construction | 660843 |
Construction | Original | / | 9/27/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 660574 |
Plan Coordinator | Original | / | 9/27/2013 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 660564 |
Enumeration | Original | A | 9/27/2013 | AMY | AMY | see site plan | | Enumeration | 660563 |
Floodplain | Original | N | 9/26/2013 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 660380 |