Black Forest Fire | Original | A | 11/12/2013 | JANE | JANE | | | Black Forest Fire | 671112 |
Health Dept. | Original | A | 11/8/2013 | HEALTHDEPT | HEALTHDEPT | The existing onsite wastewater treatment system is approved for the re-connection of the new 2-bedroom house. ON0033089 has been assigned to this property. Mike McCarthy | mmccarthy | Health Dept. | 670694 |
Health Dept. | Original | A | 11/8/2013 | HEALTHDEPT | HEALTHDEPT | The existing onsite wastewater treatment system is approved for the re-connection of the new 2-bedroom house. ON0033089 has been assigned to this property. Mike McCarthy | mmccarthy | Health Dept. | 670693 |
County Zoning | Original | A | 11/7/2013 | DSDSPAULDING | DSDSPAULDING | | | County Zoning | 670390 |
Out to Review | Original | / | 11/7/2013 | REBECCA | REBECCA | george 719-491-2199 | | Out to Review | 670338 |
Finished Bin | Original | / | 11/7/2013 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 670225 |
Mechanical | Original | A | 11/7/2013 | DALEH | DALEH | | | Mechanical | 670221 |
Out to Review | Original | / | 11/7/2013 | JANE | JANE | Brian 360 0600 | | Out to Review | 670213 |
Finished Bin | Original | / | 11/4/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 669165 |
Plan Coordinator | Original | / | 11/4/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 669160 |
Mechanical | Original | D | 11/4/2013 | RUSSELL | RUSSELL | Sheet a-2, furnace is shown as a 80% efficient, assume water heater is also with a 'B' vent, not showing a comb. air duct connecting to the main R.A. trunk, therefore, need a fully louvered door for comb. air reqmts into mech room, provide all req'd info for the duct design as indicated on the attached sheet, missing the friction loss work sheet, missing the HVAC Equipment Certificate, missing the furnace cut sheets, etc., incorrect temperatures per the attached sheet, incorrect SHR per attached sheet, incorrect ACH per attached sheet, why a duct loss shown when ducts are in a conditioned basement?, need to show all the rooms on the duct design sheet , need to move text as indicated so it's legible, need to remove duplicates, need the cut sheets to show furnaces two stages, NO WALK | | Mechanical | 669159 |
Mechanical | Original | / | 11/4/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 669120 |
Mechanical | Original | / | 11/4/2013 | | JANE | Location = Mechanical by JANE | | Mechanical | 669115 |
Resubmittal 1 | Original | / | 11/4/2013 | JANE | JANE | Resubmittal #1 | | Resubmittal 1 | 669114 |
Finished Bin | Original | / | 11/1/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 668662 |
Plan Coordinator | Original | / | 11/1/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 668657 |
Mechanical | Original | D | 11/1/2013 | RUSSELL | RUSSELL | Duct design sheet don't match floor plan, this is not a master, floor plan needs to match the architectural floor plans, basement is shown finished on architecturals and not on duct design, is duct in attic on main level?, if they are, there needs to be a loss for ducts in heat loss calculation, furnace is way oversized, missing cut sheets on furnace, SHR is incorrect, temperatures are incorrect, showing 2 different heat loss calcs? furnace is still more than 30% oversized, NO WALK | | Mechanical | 668656 |
Mechanical | Original | / | 11/1/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 668652 |
Mechanical | Original | / | 10/31/2013 | | RITA | Location = Mechanical by RITA | | Mechanical | 668579 |
Finished Bin | Original | / | 10/31/2013 | | REBECCA | Location = Finished Bin by REBECCA | | Finished Bin | 668523 |
Construction | Original | A | 10/31/2013 | SHELLEY | SHELLEY | | | Construction | 668517 |
Out to Review | Original | / | 10/31/2013 | BPHILLIPS | BPHILLIPS | Mark 310 6437 | | Out to Review | 668504 |
Finished Bin | Original | / | 10/31/2013 | | RITA | Location = Finished Bin by RITA | | Finished Bin | 668312 |
Plan Coordinator | Original | / | 10/31/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 668292 |
Mechanical | Original | D | 10/31/2013 | RUSSELL | RUSSELL | See attached duct design criteria sheets for submittal requirements for a duct design | | Mechanical | 668291 |
Mechanical | Original | / | 10/31/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 668276 |
Mechanical | Original | / | 10/24/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 666786 |
Plan Coordinator | Original | / | 10/24/2013 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 666777 |
Construction | Original | D | 10/24/2013 | JIMA | JIMA | SEE PLANS / WALK OK see page a-2 /// main floor bdrm #2 window will not meet egress | | Construction | 666776 |
Construction | Original | / | 10/24/2013 | JIMA | JIMA | In Current Review by JIMA | | Construction | 666711 |
Construction | Original | / | 10/24/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 666678 |
Plan Coordinator | Original | / | 10/24/2013 | | JEANNINE | Location = Plan Coordinator by JEANNINE | | Plan Coordinator | 666670 |
Enumeration | Original | A | 10/24/2013 | JEANNINE | JEANNINE | | | Enumeration | 666669 |
Floodplain | Original | N | 10/23/2013 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 666460 |