Health Dept. | Original | A | 1/9/2014 | HEALTHDEPT | HEALTHDEPT | ON0020116; Proposed 3 bedroom home; Existing system is approved for a 3 bedroom home; thus approved. Neil Mayes 719-575-8967. | mayescr | Health Dept. | 680815 |
County Zoning | Original | A | 1/7/2014 | DSDSPAULDING | DSDSPAULDING | | | County Zoning | 680575 |
Construction | Original | A | 1/7/2014 | JIMA | JIMA | | | Construction | 680564 |
Out to Review | Original | / | 1/7/2014 | REBECCA | REBECCA | al 719-339-0684 | | Out to Review | 680542 |
Finished Bin | Original | / | 12/30/2013 | | JANE | Location = Finished Bin by JANE | | Finished Bin | 679570 |
Mechanical | Original | A | 12/30/2013 | DALEH | DALEH | | | Mechanical | 679562 |
Out to Review | Original | / | 12/30/2013 | JANE | JANE | Trent | | Out to Review | 679555 |
Health Dept. | Original | / | 12/26/2013 | | RITA | Location = Health Dept. by RITA | | Health Dept. | 679178 |
Plan Coordinator | Original | / | 12/26/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 679173 |
Construction | Original | D | 12/26/2013 | DANM | DANM | Truss design need to be engineer stamped | | Construction | 679172 |
Resubmittal 2 | Original | / | 12/26/2013 | NELIDA | NELIDA | Resubmittal #2 12/26/13 | | Resubmittal 2 | 679170 |
Out to Review | Original | / | 12/24/2013 | JANE | JANE | 499 1257 Trent | | Out to Review | 678994 |
Finished Bin | Original | / | 12/24/2013 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 678933 |
Plan Coordinator | Original | / | 12/24/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 678921 |
Mechanical | Original | D | 12/24/2013 | RUSSELL | RUSSELL | No changes have been done to the mechanical duct design sheets or the heat loss calculations, see previous comments dated 12-17-13 | | Mechanical | 678920 |
Mechanical | Original | / | 12/24/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 678899 |
Mechanical | Original | / | 12/24/2013 | | MINDY | Location = Mechanical by MINDY | | Mechanical | 678868 |
Plan Coordinator | Original | / | 12/23/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 678863 |
Construction | Original | A | 12/23/2013 | DANM | DANM | | | Construction | 678862 |
Construction | Original | / | 12/23/2013 | DANM | DANM | In Current Review by DANM | | Construction | 678832 |
Construction | Original | / | 12/23/2013 | | BPHILLIPS | Location = Construction by BPHILLIPS | | Construction | 678798 |
Resubmittal 1 | Original | / | 12/23/2013 | BPHILLIPS | BPHILLIPS | Resubmittal #1 12/23/13 | | Resubmittal 1 | 678797 |
Out to Review | Original | / | 12/18/2013 | BPHILLIPS | BPHILLIPS | Dale 635 8109 | | Out to Review | 677932 |
Finished Bin | Original | / | 12/17/2013 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 677694 |
Plan Coordinator | Original | / | 12/17/2013 | | RUSSELL | Location = Plan Coordinator by RUSSELL | | Plan Coordinator | 677692 |
Mechanical | Original | D | 12/17/2013 | RUSSELL | RUSSELL | Provide the entire print out of the friction loss work sheet,provide just the entire house heat loss calculations, provide additional information on the furnace showing the variable and the 97,5 % efficiency, provide duct design sheets that the backgrounds are legible and will scan into the RBD data base, and label the floor plans with a scale, remove dimension lines and remove the blank floor plans that aren;t showing any ductwork on them, NO WALK | | Mechanical | 677691 |
Mechanical | Original | / | 12/17/2013 | RUSSELL | RUSSELL | In Current Review by RUSSELL | | Mechanical | 677636 |
Mechanical | Original | / | 12/17/2013 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 677632 |
Plan Coordinator | Original | / | 12/17/2013 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 677629 |
Construction | Original | D | 12/17/2013 | DANM | DANM | Provide attic access size and location Provide attic ventilation information Main Level Flr Framing - structurally inadequate beam, missing or incorrect hangers, missing header Main Level Roof/Upper Flr Framing - Missing hangers, clarify beam support, address truss uplift, identify bearing wall(s) Upper Level Roof Framing - label girder trusses with number of plys, size and material of bottom chord, address uplift, revise incorrect truss designations See plans No Walk | | Construction | 677628 |
Construction | Original | / | 12/16/2013 | DANM | DANM | In Current Review by DANM | | Construction | 677407 |
Construction | Original | / | 12/13/2013 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 677231 |
Plan Coordinator | Original | / | 12/13/2013 | | JEANNINE | Location = Plan Coordinator by JEANNINE | | Plan Coordinator | 677229 |
Enumeration | Original | A | 12/13/2013 | JEANNINE | JEANNINE | | | Enumeration | 677227 |
Floodplain | Original | N | 12/13/2013 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 677196 |