Mechanical | Original | A | 3/20/2014 | DALEH | DALEH | | | Mechanical | 694905 |
Health Dept. | Original | A | 3/19/2014 | HEALTHDEPT | HEALTHDEPT | ON0033324; no septic record on file; septic permits were not required back in 1929. The existing system is approved for a 2 bedroom home only. A new percolation test or pit observation will be required once system fails. Neil Mayes 575-8967 | mayescr | Health Dept. | 694857 |
County Zoning | Original | A | 3/19/2014 | DSDHOLLIS | DSDHOLLIS | | | County Zoning | 694683 |
Construction | Original | A | 3/19/2014 | JIMA | JIMA | | | Construction | 694593 |
Out to Review | Original | / | 3/19/2014 | BPHILLIPS | BPHILLIPS | Kellie 494 1549 | | Out to Review | 694563 |
Finished Bin | Original | / | 3/18/2014 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 694287 |
Mechanical | Original | / | 3/18/2014 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 694213 |
Mechanical | Original | / | 3/18/2014 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 694212 |
Finished Bin | Original | / | 3/12/2014 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 692922 |
Plan Coordinator | Original | / | 3/12/2014 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 692914 |
Enumeration | Original | A | 3/12/2014 | AMY | AMY | site plan has been revised. | | Enumeration | 692909 |
Construction | Original | D | 3/12/2014 | SHELLEY | SHELLEY | all ok except that PE of record has not addressed incorrect wind loading. walk ok. | | Construction | 692903 |
Out to Review | Original | / | 3/12/2014 | BPHILLIPS | BPHILLIPS | Anthony 494 1549 | | Out to Review | 692897 |
Enumeration | Original | / | 3/12/2014 | | KENYATTA | Location = Enumeration by KENYATTA | | Enumeration | 692756 |
Mechanical | Original | D | 3/12/2014 | DALEH | DALEH | waiting for res check approval prior to mechanical see complete green lines | | Mechanical | 692750 |
Mechanical | Original | / | 3/11/2014 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 692435 |
Mechanical | Original | / | 3/10/2014 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 692307 |
Plan Coordinator | Original | / | 3/10/2014 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 692306 |
Construction | Original | D | 3/10/2014 | JIMA | JIMA | SEE PLANS / WALK OK SEE PG A6 AND S1 AND S2 BASEMENT INSULATION STILL NOT MATCHING THE RES CHECK COMPLIANCE CERTIFICATE (R-19) WALLS SECTION STILL NOT CLARIFIED, A6 SAYS 2*6 WALLS AND S2 SAYS 2*4 WALLS / ALSO WIND SPEED IS 110MPH IN ELPASO COUNTY | | Construction | 692305 |
Construction | Original | / | 3/10/2014 | JIMA | JIMA | In Current Review by JIMA | | Construction | 692304 |
Construction | Original | / | 3/10/2014 | | KENYATTA | Location = Construction by KENYATTA | | Construction | 692265 |
Resubmittal 1 | Original | / | 3/10/2014 | JANE | JANE | Resubmittal #1 | | Resubmittal 1 | 692264 |
Out to Review | Original | / | 2/3/2014 | MINDY | MINDY | Kellie 494 1549 | | Out to Review | 684925 |
Finished Bin | Original | / | 2/3/2014 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 684811 |
Health Dept. | Original | / | 1/31/2014 | | KENYATTA | Location = Health Dept. by KENYATTA | | Health Dept. | 684696 |
Mechanical | Original | D | 1/31/2014 | DALEH | DALEH | no review until construction comments have been addressed | | Mechanical | 684693 |
Mechanical | Original | / | 1/31/2014 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 684665 |
Mechanical | Original | / | 1/31/2014 | | KENYATTA | Location = Mechanical by KENYATTA | | Mechanical | 684655 |
Plan Coordinator | Original | / | 1/31/2014 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 684649 |
Construction | Original | D | 1/31/2014 | JIMA | JIMA | SEE PLANS / NO WALK add all red line corrections to new sheets and resubmit old sheets with new sheets see rescheck - use new IECC sheet and fill it out per the notes on the old rescheck and old IECC sheet code info incorrect / smoke det. and co detectors / the plans need to be drawn to scale correct all pages show basement on elevations including windows / provide cross section for front shed roof and include all framing information IE: attachment to house, beam, rafter connections, angle support connection, ETC> provide section drawing through stairs and call out all information IE: rise, run, head room, hand rail, ETC see framing not on plan pg s2.01 / call out roof and floor live and dead loads on framing plans not foundation label ALL trusses on plans at their locations / stair beam inadequate as single / SEE PLANS FOR ALL NOTES | | Construction | 684648 |
Construction | Original | / | 1/30/2014 | JIMA | JIMA | In Current Review by JIMA | | Construction | 684420 |
Construction | Original | / | 1/30/2014 | | MINDY | Location = Construction by MINDY | | Construction | 684366 |
Plan Coordinator | Original | / | 1/30/2014 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 684360 |
Enumeration | Original | D | 1/30/2014 | AMY | AMY | Is this property proposed to re-plat? because the site plan does not depict what the Assessor's data base does. Also Rhine street doesn't come through this property like site plan shows, indicate where drive way is proposed coming into the lot. | | Enumeration | 684359 |
Floodplain | Original | N | 1/28/2014 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 684073 |