PROCESSING....
This is hidden content to make Wave think this is not a heading
Skip to main content
Pikes Peak Regional Building Department
Ensuring life safety and welfare of our community through efficient and consistent application of adopted codes and standards.
Home
Contact
Search
Accessibility
Cart
Sign In
Home
Contact
Search
Accessibility
Cart
Sign In
Plan Details
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Plan #
  
Type
 
Plan
Owner
Address
13415 BRENTWOOD DR, COLORADO SPRINGS, CO 80908
Permit #
J31557
Parcel Info
5208000044
Truss P/SF
40 (Elevation: 7,468 Feet)
Bedrooms
4
Project
RESIDENCE - ENGINEER STAMPED - BFF (
101
)
Type Of Plan
Normal
Review Type
Single Copy
Fire District
BLACK FOREST FIRE PROTECTION DISTRICT
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 6
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Construction
A
0
C
Construction
Enumeration
A
0
N
Enumeration
Floodplain
N
W
Floodplain
EPC Health Dept
A
0
H
EPC Health Dept
Mechanical
A
0
M
Mechanical
County Zoning
A
0
Z
County Zoning
Log Entries: 17
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
Mechanical
Original
A
8/13/2014
DALEH
DALEH
Mechanical
726457
Health Dept.
Original
A
8/13/2014
NELIDA
NELIDA
HD ON0033033
Health Dept.
726402
County Zoning
Original
A
8/12/2014
DSDRANGEL
DSDRANGEL
County Zoning
726246
Construction
Original
A
8/12/2014
MICHAELA
MICHAELA
Construction
726235
Out to Review
Original
/
8/12/2014
MINDY
MINDY
Jorge 495 9200
Out to Review
726214
Finished Bin
Original
/
8/5/2014
BPHILLIPS
Location = Finished Bin by BPHILLIPS
Finished Bin
724984
Plan Coordinator
Original
/
8/5/2014
RUSSELL
Location = Plan Coordinator by RUSSELL
Plan Coordinator
724955
Mechanical
Original
D
8/5/2014
RUSSELL
RUSSELL
On the architectural sheet 3, provide 100 square inch makeup air opening into the laundry room, verify location of vent up from basement, add exhaust fans as noted and provide IECC Certificate to verify insulation R & U values with the plan and the heat loss calculations, duct design okay as are the heat loss calculations unless the R & U values change with the submittal of the IECC Cert
Mechanical
724954
Mechanical
Original
/
8/5/2014
RUSSELL
RUSSELL
In Current Review by RUSSELL
Mechanical
724859
Mechanical
Original
/
8/5/2014
BPHILLIPS
Location = Mechanical by BPHILLIPS
Mechanical
724854
Plan Coordinator
Original
/
8/5/2014
DANM
Location = Plan Coordinator by DANM
Plan Coordinator
724845
Construction
Original
D
8/5/2014
DANM
DANM
Provide IECC Certificate
Provide attic access location and size
Calrify type of fireplace
Master bedroom windows do not meet egress requirements
Clarify if conditioned or unconditioned crawlspace
See plans
Walk OK
Construction
724844
Construction
Original
/
8/5/2014
DANM
DANM
In Current Review by DANM
Construction
724827
Construction
Original
/
8/4/2014
BPHILLIPS
Location = Construction by BPHILLIPS
Construction
724599
Plan Coordinator
Original
/
8/4/2014
JEANNINE
Location = Plan Coordinator by JEANNINE
Plan Coordinator
724597
Enumeration
Original
A
8/4/2014
JEANNINE
JEANNINE
Enumeration
724596
Floodplain
Original
N
8/1/2014
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain
Floodplain
724380