Plan Coordinator | 7/5/16 | / | 7/12/2016 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 886636 |
Mechanical | 7/5/16 | A | 7/12/2016 | JUSTINC | JUSTINC | Revised for new duct design and new calcs | | Mechanical | 886634 |
Mechanical | 7/5/16 | / | 7/12/2016 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 886608 |
Mechanical | 7/5/16 | / | 7/5/2016 | | NELIDA | Location = Mechanical by NELIDA | | Mechanical | 884901 |
Out to Review | Original | / | 5/29/2015 | REBECCA | REBECCA | alicia | | Out to Review | 788016 |
Health Dept. | Original | A | 5/29/2015 | HEALTHDEPT | HEALTHDEPT | ON0021064: New septic plans for a 5 bedroom home have been submitted. Plans are approved. Neil Mayes 575-8967 | mayescr | Health Dept. | 788012 |
Health Dept. | Original | D | 3/23/2015 | HEALTHDEPT | HEALTHDEPT | ON0021064: Existing septic system is an engineer design system that was sized for a 2 bedroom only. Thus the proposed 5 bedroom home is disapproved. Geoquest, LLC shall be notified by the owner for a new design that is properly sized for a 5 bedroom home and plans shall be submitted to El Paso County Public Health for approval. Neil Mayes 575-8967 | mayescr | Health Dept. | 770362 |
Scanned/Finished Bin | Original | / | 3/10/2015 | | KENYATTA | Location = Scanned/Finished Bin by KENYATTA | | Scanned/Finished Bin | 767171 |
To Be Scanned Bin | Original | / | 3/10/2015 | | KENYATTA | Location = To Be Scanned Bin by KENYATTA | | To Be Scanned Bin | 767098 |
Plan Coordinator | Original | / | 3/10/2015 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 767085 |
Construction | Original | A | 3/10/2015 | DANM | DANM | | | Construction | 767084 |
Construction | Original | / | 3/10/2015 | DANM | DANM | In Current Review by DANM | | Construction | 767016 |
Construction | Original | / | 3/6/2015 | | BPHILLIPS | Location = Construction by BPHILLIPS | | Construction | 766515 |
Resubmittal 2 | Original | / | 3/6/2015 | BPHILLIPS | BPHILLIPS | Resubmittal #2 3/6/15 | | Resubmittal 2 | 766514 |
Out to Review | Original | / | 3/3/2015 | NELIDA | NELIDA | Alicia 719-641-4149 | | Out to Review | 765532 |
Finished Bin | Original | / | 2/27/2015 | | KENYATTA | Location = Finished Bin by KENYATTA | | Finished Bin | 765033 |
Plan Coordinator | Original | / | 2/27/2015 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 765010 |
Construction | Original | D | 2/27/2015 | DANM | DANM | Multiple trusses over open porches or decks need to be re-designed as 'partially' enclosed Truss AK1 should have mechanical fastener one side per framing plan Clarify walls dividing lower level such that one cannot get from one space to the next Clarify front unlabeled room in lower level See plans No walk-through review allowed | | Construction | 765009 |
Construction | Original | / | 2/27/2015 | DANM | DANM | In Current Review by DANM | | Construction | 764983 |
Construction | Original | / | 2/27/2015 | | NELIDA | Location = Construction by NELIDA | | Construction | 764962 |
Resubmittal 1 | Original | / | 2/27/2015 | NELIDA | NELIDA | Resubmittal #1 2/27/15 | | Resubmittal 1 | 764961 |
Out to Review | Original | / | 2/27/2015 | NELIDA | NELIDA | Alicia 719-641-4149 | | Out to Review | 764946 |
Finished Bin | Original | / | 1/8/2015 | | MINDY | Location = Finished Bin by MINDY | | Finished Bin | 755443 |
Plan Coordinator | Original | / | 1/8/2015 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 755442 |
Mechanical | Original | A | 1/8/2015 | TCRIPPEN | TCRIPPEN | | | Mechanical | 755441 |
Mechanical | Original | / | 1/8/2015 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Mechanical | 755415 |
Mechanical | Original | / | 1/7/2015 | | MINDY | Location = Mechanical by MINDY | | Mechanical | 755342 |
Plan Coordinator | Original | / | 1/7/2015 | | DANM | Location = Plan Coordinator by DANM | | Plan Coordinator | 755337 |
Construction | Original | D | 1/7/2015 | DANM | DANM | Multiple trusses over open porches or decks need to be designed as 'partially' enclosed Truss AK1 should have mechanical fastener one side per framing plan Clarify walls dividing lower level such that one can get from one space to the next Clarify front unlabeled room in lower level Multiple trusses require uplift to be addressed Specify various missing hangers on roof framing Beam structurally inadequate by over 300% on roof framing Clarify how rear wall meets prescriptive wall bracing method or provide stamped engineering Clarify connection of beams to foundation wall - provide detail - significant point load from girder truss above Clarify connection of front joists to wall Review stopped - provide steel beam sizes or provide engineer stamped structural drawings See plans No walk-through review allowed | | Construction | 755336 |
Construction | Original | / | 1/7/2015 | DANM | DANM | In Current Review by DANM | | Construction | 755204 |
Construction | Original | / | 1/7/2015 | | MINDY | Location = Construction by MINDY | | Construction | 755198 |
Plan Coordinator | Original | / | 1/7/2015 | | AMY | Location = Plan Coordinator by AMY | | Plan Coordinator | 755191 |
Enumeration | Original | A | 1/7/2015 | AMY | AMY | | | Enumeration | 755190 |
Enumeration | Original | / | 1/6/2015 | | MINDY | Location = Enumeration by MINDY | | Enumeration | 755134 |
County Zoning | Original | A | 12/23/2014 | DSDRANGEL | DSDRANGEL | | | County Zoning | 753305 |
Out to Review | Original | / | 12/22/2014 | BPHILLIPS | BPHILLIPS | homeowner walking to zoning | | Out to Review | 752963 |
Floodplain | Original | N | 12/22/2014 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain | | Floodplain | 752957 |